background image

Selectronic Authorised Service Network 

 
 

Selectronic Australia 

Suite 5,  20 Fletcher Road 

Mooroolbark 

Victoria      3138 

Australia 

Ph:   +61 3 9727 6600 

Fax:  +61 3 9727 6601 

www.selectronic.com.au 

[email protected] 

 

 

Burley TV Service 

Rainbow Power Company 

278 Edmondson Ave. 

1 Alternative Way 

Austral 

Nimbin 

NSW      2171 

NSW 2480 

Australia 

Australia 

Ph: 02 9606-0279 

Ph:   02 6689 1430 

 

Fax:  02 6689 1109 

 

 

 

 

Solar Inverter Services 

Reid Technology 

13 Thirteenth Ave. 

Unit D, 15-17 Saturn Place 

Sawtell 

North Harbour 

NSW 

Auckland 1330 

2452 

New Zealand 

Ph: 02 66581733 

Ph:   9 489-8100 

 

Fax:  9 489-8585 

 

[email protected] 

 

 

 
 

 

Suite 5,  20 Fletcher Road Mooroolbark Victoria 3138 Australia

 

Phone +61 3 9727 6600   Fax 

+61 3 9727 6601 

Web 

www.selectronic.com.au

 Email

 [email protected]

 

 

 

CS0135 Rev 04  Part No. 003620 

 

 . 

 

 

 

 

 

 

 

 

LD600-12 Operating Manual 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Serial No  _____________________________  

Purchase Date  ______________ 

Note - Your warranty can only be valid once your warranty card is completed and returned to Selectronic Australia 

 

 

Summary of Contents for LD600-12

Page 1: ...erter Services Reid Technology 13 Thirteenth Ave Unit D 15 17 Saturn Place Sawtell North Harbour NSW Auckland 1330 2452 New Zealand Ph 02 66581733 Ph 9 489 8100 Fax 9 489 8585 psands reidtechnology co nz Suite 5 20 Fletcher Road Mooroolbark Victoria 3138 Australia Phone 61 3 9727 6600 Fax 61 3 9727 6601 Web www selectronic com au Email sales selectronic com au CS0135 Rev 04 Part No 003620 LD600 12...

Page 2: ...c Service Network Back Cover Legend for Symbols Warnings and electrician s notes Hints and Pointers Examples LD600 12 Manual Selectronic Australia 17 Miscellaneous Specifications Reverse Polarity Protection Output Voltage Accuracy 0 350 watts Output Frequency Peak Efficiency Total Harmonic Distortion Memory Retention Operating Temperature Range Transformer Type Cooling Method Power Point Chassis M...

Page 3: ...ctronic Australia 1 Introduction Thank you for choosing to purchase the Selectronic LD600 12 TRUE SINE WAVE inverter Many hours of Research and Development have gone into the LD600 12 to ensure this inverter provides you with many years of reliable service Warranty Card It is imperative that you complete your warranty card NOW Your LD600 12 is covered by a TWO year warranty this warranty is in add...

Page 4: ...ear the cost of parts and labour to repair any faults found within the terms and period of this warranty Faulty product or parts must be returned to Melbourne Australia at the owner s expense for claim under warranty No allowance is made for the cost of labour or traveling time required to disconnect or reinstall faulty parts Cost of freight to return parts to the customer will be paid by the manu...

Page 5: ...ll loads will still bring the inverter ON when required Inverter shuts down during the middle of the day and comes back ON late in the afternoon This is more than likely caused by high battery volts during peak charging times from Solar Panels Battery volts should never exceed 17 volts If this is the case have your Solar Regulator checked LD600 12 Manual Selectronic Australia 3 Portable Use By usi...

Page 6: ...n series add the voltage of each battery The capacity will equal the capacity of the smallest battery 2 x 6 Volt 150 Ah batteries connected in series would have a total capacity of 12 Volts 150 Ah LD600 12 Manual Selectronic Australia 13 Radio Frequency Interference Radio Frequency Interference RFI can be a problem for owners of inverters RFI in a domestic situation may produce noise or interferen...

Page 7: ...n parallel add the capacities together the voltage will remain the same as each batteries voltage 2 x 12 Volt 150 Ah batteries connected in parallel would have a capacity of 12 Volts 300 Ah Only use identical batteries when joining batteries together How long will my battery last To work out how long your battery will last follow this basic guide This guide presumes commencing with a fully charged...

Page 8: ...or any obstructions to the black cooling heatsink at the rear of the inverter The heatsink must be cleared of any accumulated foreign matter that may have lodged itself between the fins since the last maintenance check e g insect nests Also verify that airflow around the inverter has not become restricted Batteries 1 Every week carry out a thorough visual inspection of all battery wiring taking pa...

Page 9: ... front panel to indicate a number of parameters and allow adjustment of some of these parameters LED 5 tells you what LED 1 4 is displaying as indicated on the front panel of the LD600 12 Pressing Mode Button 7 will change the information being displayed STATUS indicators LED 5 green flashing When power is first applied LED 1 should flash When LED 5 green is OFF this indicates the LED 1 4 is showi...

Page 10: ...will FLASH The LED will remain ON or FLASHING until the temperature has lowered to a safe level the inverter will then come back ON If this LED 4 is coming on regularly either reduce the amount of load on the inverter or try to move the inverter to a cooler location LD600 12 Manual Selectronic Australia 9 Demand Start Adjust LED 5 green ON It is sometimes necessary to adjust the demand start sensi...

Reviews: