ENFORCER Voice Dialer 

16

 

SECO-LARM U.S.A., Inc. 

 

Dialer will not arm/disarm 

 

Try re-entering the PIN number to ensure that you have 
entered it correctly. 

 

While pressing and holding the [PROG] button, use a pen or 
paper clip to press the [RESET] button on the back of the 
dialer. This sets the PIN number to the default (000).Then try 
to arm/disarm again. 

Dialer will not dial out 

 

Make sure that the telephone line is working. 

 

Make sure that you have programmed at least one 
telephone number into the unit and that the full number has 
been stored. 

 

Make sure that the system is in Auto Dial mode. 

 

Ensure that the line to the wall jack is plugged into the 
dialer’s “LINE” jack, and any phone extension connected to 
the dialer is plugged into the dialer’s “TEL” jack.  

Unit doesn’t respond to a call-
back 

 

Check to see if another unit (fax or answering machine) 
could be answering the call and remove the other unit. 

 

Adjust the call-in ring detect setting so the dialer will answer. 

Difficulty in activating ‘room 
monitor’ by telephone remote 
control 

 

Try pressing the code key again.  

 

Move to a quieter location as ambient noise may affect the 
dialer’s ability to detect the tone signal. 

Troubleshooting:  

NOTICE: 

The  information  and  specifications  printed  in  this  manual  are  current  at  the  time  of  publication. 

However,  the  SECO-LARM  policy  is  one  of  continual  development  and  improvement.  For  this  reason, 
SECO-LARM reserves the right to change specifications without notice. SECO-LARM is also not responsible 
for misprints or typographical errors. 
Copyright  ©  2014  SECO-LARM  U.S.A.,  Inc.  All  rights  reserved.  This  material  may  not  be  reproduced  or 
copied, in whole or in part, without the written permission of SECO-LARM. 

SECO-LARM

 

®

  

U.S.A., Inc.

 

16842 Millikan Avenue, Irvine, CA 92606 

Website: www.seco-larm.com 

Phone: (949) 261-2999  |  (800) 662-0800  Email: [email protected] 

IMPORTANT:

 

Users and installers of this product are responsible for ensuring this product complies with all 

national,  state,  and  local  laws  and  statutes  related  to  monitoring  and  recording  audio  and  video  signals. 
SECO-LARM

 

will  not  be  held  responsible  for  the  use  of  this  product  in  violation  of  any  current  laws  or 

statutes. 

NOTE:

 

While the system can provide valuable protection to home and property when properly installed, it 

cannot  guarantee  complete  protection  against  intrusion.  SECO-LARM  is  not  responsible  for  any  losses  or 
damage which may occur during the use of this product. 

 

®

 

PIHLK1 

 

MiE-921CPQ_141204.docx 

 

WARRANTY:

 

This  SECO-LARM  product  is  warranted  against  defects  in  material  and  workmanship  while 

used  in  normal  service  for  one  (1)  year  from  the  date  of  sale  to  the  original  customer.  SECO-LARM’s 
obligation is limited to the repair or  replacement of any defective part if the unit is returned, transportation 
prepaid, to SECO-LARM. This Warranty is void if damage is caused by or attributed to acts of God, physical 
or electrical misuse or abuse, neglect, repair or alteration, improper or abnormal usage, or faulty installation, 
or if for any other reason SECO-LARM determines that such equipment is not operating properly as a result 
of  causes  other  than  defects  in  material  and  workmanship.  The  sole  obligation  of  SECO-LARM  and  the 
purchaser’s exclusive remedy shall be limited to the replacement or repair only, at SECO-LARM’s option. In 
no  event  shall  SECO-LARM  be  liable  for  any  special,  collateral,  incidental,  or  consequential  personal  or 
property damage of any kind to the purchaser or anyone else. 

 

  

 

 

 

 

Voice Dialer 

Manual 

 

When triggered by an alarm system, the ENFORCER Voice Dialer can call up to 5 numbers and deliver 
a user-recorded 20-second voice message, playing repeatedly for one minute. Each number can 
contain up to 32 digits, including #, tones, and pauses. The LCD shows the number being dialed at each 
stage of the dialing process. The receiver can then listen in or broadcast a message to the room 
occupants or can disarm the system. The same functions are available by remote call in as well as 
arming the system. The dialer includes a home mode (acting like a door chime when the owner is 
present) and a panic button. The 105dB built-in siren alarm can be programmed on or off.  

 

 

Models Available 

Certification 

E-921CPQ 

 

E-921KPQ 

 

 

Содержание Enforcer E-921CPQ

Страница 1: ...ed to monitoring and recording audio and video signals SECO LARM will not be held responsible for the use of this product in violation of any current laws or statutes NOTE While the system can provide valuable protection to home and property when properly installed it cannot guarantee complete protection against intrusion SECO LARM is not responsible for any losses or damage which may occur during...

Страница 2: ...Planner 14 FCC Part 68 14 Summary Programming Operation Chart 15 Also Available from SECO LARM 15 Troubleshooting 16 ENFORCER Voice Dialer SECO LARM U S A Inc 15 Summary Programming Operation Chart 1 Setting Changing PIN Number see pg 6 Current PIN PROG ARM DISARM New PIN ARM DISARM PROG x9 2 Setting Emergency Telephone Numbers see pgs 6 7 PIN PROG x2 ARM DISARM DOWN or UP Enter Phone ARM DISARM P...

Страница 3: ...ould affect the operation of the equipment If this happens the telephone company will provide advance notice in order for you to make necessary modifications to maintain uninterrupted service If trouble is experienced with this equipment US 7M7TE02BE921CPQ for repair or warranty information please contact SmartRG Inc If the equipment is causing harm to the telephone network the telephone company m...

Страница 4: ... chime will sound and the word HOME will appear on the LCD screen 2 After 60 seconds another chime indicates that the voice dialer is now in the Home mode 3 When a sensor is activated the voice dialer will chime twice 4 If the panic button is pressed the voice dialer will sound a 30 second alarm and start the dialing sequence to the programmed emergency numbers To deactivate the Home mode simply p...

Страница 5: ...m system 5 Disarm system 6 The user should hear a beep in response If not enter the function code again ENFORCER Voice Dialer SECO LARM U S A Inc 5 Installing the Voice Dialer continued 1 Select a location for the dialer near a standard electrical outlet if user supplied 12VDC adapter is to be used a telephone wall jack and the alarm control panel but out of sight The dialer should not be exposed ...

Страница 6: ... and holding for two seconds the DOWN or UP buttons respectively The sign shows as and the sign shows as on the LCD screen ENFORCER Voice Dialer SECO LARM U S A Inc 11 2 To disarm the system enter the PIN number and press the ARM DISARM button The dialer will sound a long beep and the word ARM will disappear from the LCD screen Panic Button Use 1 When the PANIC button is pressed the siren will sou...

Страница 7: ...nnected only to the TEL jack of the dialer ENFORCER Voice Dialer SECO LARM U S A Inc 7 Deleting a Stored Phone Number 1 Enter the PIN number and press the PROG button twice or until MEMORY flashes on the LCD screen 2 Press the ARM DISARM button to accept 3 Press the DOWN or UP button to select the number you wish to delete 4 Press the DEL PAUSE button to delete the number 5 Press the DOWN or UP bu...

Страница 8: ...programming icons disappear to exit the setup mode ENFORCER Voice Dialer SECO LARM U S A Inc 9 Programming the Voice Dialer continued Setting the Entry Delay Time This allows the user to set the length of time before the alarm will sound to allow time to disable the alarm after normal entry The factory default is 20 seconds but can be user programmed for 0 5 10 15 or 20 seconds 1 Enter the PIN num...