background image

INSTRUCTIONS FOR:

WELDING FUME EXTRACTOR

MODEL NO:

WFS/94.V2

1.2.

GENERAL SAFETY

Use unit for the extraction of welding fumes from torches, suction masks, suction hoods. No other use of product is permitted.

Unplug the product from the mains power supply before cleaning, checking, or maintenance.

Keep this product in good working order and condition. 

(Take immediate action to repair or replace damaged parts).

Regularly check cables, suction hose, and filters to ensure they are in good condition. Use recommended parts only. 

(Non recommended 

parts may be dangerous and will invalidate the warranty).

Keep this equipment dry at all times.

Keep children and unauthorised persons away from the working area.

!

Locate in adequate working area which is clean and tidy and free from unrelated materials, and has adequate lighting.

DO NOT use the equipment for the extraction of vapours or water mists, or for acid and/or corrosive vapours and flammable substances.

DO NOT extract any substances which are dangerous to health such as: Asbestos, cadmium, lead, beryllium, etc.

DO NOT point the extraction hose at yourself, or others.

DO NOT obstruct pathways, passageway, etc, with the extraction hose. (Ensure the hose is safely laid out).

DO NOT use this product to perform a task for which it has not been designed.

DO NOT use whilst under the influence of drugs, alcohol or intoxicating medication.

DO NOT use the unit out of doors, protect from the elements at all times.

Keep equipment clean and dry and store in a safe childproof area when not in use.

Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions 
and properly maintained, give you years of trouble free performance.

IMPORTANT

BEFORE USING THIS PRODUCT, PLEASE READ THE INSTRUCTIONS CAREFULLY. MAKE CAREFUL NOTE OF SAFETY
INSTRUCTIONS, WARNINGS AND CAUTIONS. THIS PRODUCT SHOULD ONLY BE USED FOR ITS INTENDED PURPOSE. 
FAILURE TO DO SO MAY CAUSE DAMAGE OR PERSONAL INJURY, AND WILL INVALIDATE THE WARRANTY.

WFS/94.V2 (1) 10/11/06

2. APPLICATION & SPECIFICATION

Stand-alone extractor designed to filter out harmful fumes from the atmosphere. Fitted with spark and charcoal filter to remove large
concentrations of ozone gas from fumes, this unit is recommended for professional use. Supplied with extractor hose and collector nozzle.
230Volt Power supply required.

Aspirator motor . . . . . . 1000watts, 220/230V 50Hz
Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . Charcoal
Power Supply: . . . . . . . . . . . . . . . . . . . 230V - 1ph

Diameter of inlet opening . . . . . . . . . . . . . . 50mm
Capacity . . . . . . . . . . . . . . . . . . . . . . . . . 150m³/hr
Noise Level . . . . . . . . . . . . . . . . . . . . . . < 83.5dB 

Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18kg
Overall Dimensions . . . . . . . . . . 360x530x250mm

1.1.

ELECTRICAL SAFETY

$  

WARNING!

It is the responsibility of the owner and the operator to read, understand and comply with the following:

You must check all electrical products, before use, to ensure that they are safe. You must inspect power cables, plugs, sockets and any other
connectors for wear or damage. You must ensure that the risk of electric shock is minimised by the installation of appropriate safety devices.
A Residual Current Circuit Breaker (RCCB) should be incorporated in the main distribution board. We also recommend that a Residual Current
Device (RCD) is used. It is particularly important to use an RCD with portable products that are plugged into a supply which is not protected
by an RCCB. If in any doubt consult a qualified electrician. You may obtain a Residual Current Device by contacting your Sealey dealer. 

You must

also read and understand the following instructions concerning electrical safety.

1.1.1. The 

Electricity at Work Act 1989 

requires that all portable electrical appliances, if used on business premises, are tested by a qualified

electrician, using a Portable Appliance Tester (PAT), at least once a year.

1.1.2. The 

Health & Safety at Work Act 1974 

makes owners of electrical appliances responsible for the safe condition of those appliances

and the safety of the appliance operators. 

If in any doubt about electrical safety, contact a qualified electrician.

1.1.3. Ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply. See 1.1.1. and 1.1.2.

and use a Portable Appliance Tester.

1.1.4. Ensure that cables are always protected against short circuit and overload.
1.1.5. Regularly inspect power supply cables and plugs for wear or damage and check all

connections to ensure that none is loose.

1.1.6.

Important:

Ensure that the voltage marked on the appliance matches the power supply 

to be used and that the plug is fitted with the correct fuse - see fuse rating at right.

1.1.7.

DO NOT

pull or carry the appliance by the power cable.

1.1.8.

DO NOT 

pull the plug from the socket by the cable.

1.1.9.

DO NOT

use worn or damaged cables, plugs or connectors. Immediately have any faulty

item repaired or replaced by a qualified electrician. When a BS 1363/A UK 3 pin plug is 
damaged, cut the cable just above the plug and 

dispose of the plug safely. 

Fit a new plug according to the following instructions (UK only).

a) Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.
b) Connect the BROWN live wire to the live terminal ‘L’.
c) Connect the BLUE neutral wire to the neutral terminal ‘N’.
d) After wiring, check that there are no bare wires, that all wires have been correctly connected, that the cable outer insulation

extends beyond the cable restraint and that the restraint is tight.

1.1.10. If an extension reel is used it should be fully unwound before connection. A reel with an RCD fitted is preferred since any appliance

plugged into it will be protected. The cable core section is important and should be at least 1.5mm

2

, but to be absolutely sure that the

capacity of the reel is suitable for this product and for others which may be used in the other output sockets, we recommend the use of
2.5mm

2

section cable.

1.

SAFETY INSTRUCTIONS

FUSE RATING 13 AMP

Blue
Neutral 
Wire

Yellow & Green 
Earth Wire 

Cable 
Restraint

Brown
Live 
Wire

Reviews: