background image

INSTRUCTIONS FOR:

STEEL BLADED CUT-OFF SAW

Model: 

SM11.V2

Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions 

and properly maintained, give you years of trouble free performance.

1. SAFETY INSTRUCTIONS

IMPORTANT:

PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS AND

CAUTIONS. USE THIS PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY

CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.

1.2

GENERAL SAFETY

p

WARNING!

Disconnect the saw from the mains power, and ensure the cutting blade is at 

a complete standstill before attempting

to change accessories, service or perform any maintenance.

3

Maintain the saw in good condition (use an authorised service agent).

3

Replace or repair damaged parts. 

Use recommended parts only. Unauthorised parts may 

be dangerous and will invalidate the warranty.

3

Locate the saw in an adequate working area for its function. Ensure the surface is flat and

firm. Keep area clean and tidy and free from

unrelated materials, and ensure there is adequate lighting.

3

Keep the saw clean for best and safest performance and check moving parts alignment 

regularly. 

p

WARNING! 

Before each use check that blade is secure and that it is not worn or damaged.

If worn or damaged replace immediately.

p

WARNING!

Keep guard and holding screws in place, tight and in good working order. 

Check regularly for damaged parts. 

A guard, or any other part, that is damaged should be replaced with a new one, to ensure that it operates properly and performs its intended

function, before the tool is used. The safety guard is a mandatory fitting where saw is used in premises covered by the Health & Safety at 

Work Act.

3

Remove adjusting keys and wrenches from the machine and it’s vicinity before turning it on.

p

WARNING! 

Wear approved safety eye protection, ear defenders, and gauntlets, and, if dust is generated, respiratory protection.

3

Remove ill fitting clothing. Remove ties, watches, rings and other loose jewellery and contain long hair.

3

Keep hands and body clear of the work table when operating the saw and position your body in line with the blade whilst cutting.

3

Maintain correct balance and footing. Ensure the floor is not slippery and wear non-slip shoes.

3

Always clamp workpiece in the base vice. NEVER hold a work piece by hand.

3

Keep children and unauthorised persons away from the working area.

SM11.V2 - 1 - 010802

1.1.

ELECTRICAL SAFETY

p  

WARNING!

It is the responsibility of the owner and the operator to read, understand and comply with the following:

You must check all electrical products, before use, to ensure that they are safe. You must inspect power cables, plugs, sockets and any other

connectors for wear or damage. You must ensure that the risk of electric shock is minimised by the installation of appropriate safety devices.

A Residual Current Circuit Breaker (RCCB) should be incorporated in the main distribution board. We also recommend that a Residual Current

Device (RCD) is used. It is particularly important to use an RCD with portable products that are plugged into a supply which is not protected

by an RCCB. If in any doubt consult a qualified electrician. You may obtain a Residual Current Device by contacting your Sealey dealer. 

You must

also read and understand the following instructions concerning electrical safety.

1.1.1. The 

Electricity at Work Act 1989 

requires all portable electrical appliances, if used on business premises, to be tested by a qualified

electrician, using a Portable Appliance Tester (PAT), at least once a year.

1.1.2. The 

Health & Safety at Work Act 1974 

makes owners of electrical appliances responsible for the safe condition of those appliances

and the safety of the appliance operators. 

If in any doubt about electrical safety, contact a qualified electrician.

1.1.3. Ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply. See 1.1.1. and 1.1.2.

and use a Portable Appliance Tester.

1.1.4. Ensure that cables are always protected against short circuit and overload.

1.1.5. Regularly inspect power supply cables and plugs for wear or damage and check all

connections to ensure that none is loose.

1.1.6.

Important:

Ensure that the voltage marked on the appliance matches the power supply 

to be used and that the plug is fitted with the correct fuse - see fuse rating at right.

1.1.7.

DO NOT

pull or carry the appliance by the power cable.

1.1.8.

DO NOT 

pull the plug from the socket by the cable.

1.1.9.

DO NOT

use worn or damaged cables, plugs or connectors. Immediately have any faulty

item repaired or replaced by a qualified electrician. When an ASTA/BS approved UK

3 pin plug is damaged, cut the cable just above the plug and 

dispose of the plug safely.

Fit a new plug according to the following instructions (UK only).

a) Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.

b) Connect the BROWN live wire to the live terminal ‘L’.

c) Connect the BLUE neutral wire to the neutral terminal ‘N’.

d) After wiring, check that there are no bare wires, that all wires have been correctly connected, that the cable outer insulation

extends beyond the cable restraint and that the restraint is tight.

Double insulated products, which are always marked with this symbol      , are fitted with live (brown) and neutral (blue) wires only.

To rewire, connect the wires as indicated above - 

DO NOT

connect either wire to the earth terminal.

1.1.10. Products which require more than 13 amps are supplied without a plug. In this case you must contact a qualified electrician to ensure that a

suitably rated supply is available. We recommend that you discuss the installation of an industrial round pin plug and socket with your electrician.

1.1.11. If an extension reel is used it should be fully unwound before connection. A reel with an RCD fitted is preferred since any appliance

plugged into it will be protected. The cable core section is important and should be at least 1.5mm

2

, but to be absolutely sure that the

capacity of the reel is suitable for this product and for others which may be used in the other output sockets, we recommend the use of

2.5mm

2

section cable.  If extension reel is to be used outdoors, ensure it is marked for outdoor use.

FUSE RATING 13 AMP

Blue

Neutral 

Wire

Yellow & Green 

Earth Wire 

Cable 

Restraint

Brown

Live 

Wire