background image

INSTRUCTIONS FOR: 

ELECTRONIC VERNIER CALLIPER 

MODEL NO:

AK9622EV

Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according
to these instructions and properly maintained, give you years of trouble free performance.

IMPORTANT

PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL
REQUIREMENTS, WARNINGS, AND CAUTIONS. USE THIS PRODUCT CORRECTLY AND
WITH CARE, FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY
CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY.

!

!

WARNING! Ensure Health and Safety, local authority and general workshop practice regulations 
are adhered to when using tools and equipment.

"

DO NOT

use calliper if damaged.

#

Maintain calliper in good and clean condition for best and safest performance.

#

Keep the work area clean, uncluttered and ensure there is adequate lighting.

#

Maintain correct balance and footing. Ensure the floor is not slippery and wear non-slip shoes.

#

Keep children and unauthorised persons away from the work area.

1.

SAFETY INSTRUCTIONS

2. INTRODUCTION & SPECIFICATION

Hardened and tempered stainless steel calliper with satin finish. 11mm High figures in LCD display for ease of
reading. Metric and Imperial calibration with conversion between the two. Zero setting control allows for
comparative measurement. Supplied in carry-case.

1

Internal Measure

2

Metric/Imperial Selector

3

Locking Screw

4

ABS/0 Switch

5 LCD Display
6

External Measure

7

On/Off Control

8

Zero Control

9

Battery Cover

10     Depth Measure
11     Step Measure

AK9622EV - (2) - 24/03/06

Specification:

Resolution . . . . . . . . . . . . . . . . . . . . . . . . . . 0.01mm (0.0005”)
Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200mm (8”)
Accuracy. . . . . . . . . . . . . . . . . ±0.02mm (±0.001”) @ <100mm

. . . . . . . . . . . . . . . . . . . . . . . . ±0.03mm (±0.001”) @ >100mm

Repeatability . . . . . . . . . . . . . . . . . . . . . . . . 0.01mm (0.0005”)
Functions . . . Zero set, mm/inch select, incremental zero, ABS
Messages . . . . . . . . . . . . . . Flashing display = replace battery 
Battery life . . . . . . . . . . . . . . . . . . . . . . . . . . Approx. two years 

. . . . . . . . . . . . . . . . . (approx. one year in continuous service)

Battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SR44 - 1.55V
Operational Temperature range . . . . . . . . . . . . . . . . . 5 - 40

O

C

INSTRUCTIONS FOR: 

ELECTRONIC VERNIER CALLIPER 

MODEL NO:

AK9622EV

Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according
to these instructions and properly maintained, give you years of trouble free performance.

IMPORTANT

PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL
REQUIREMENTS, WARNINGS, AND CAUTIONS. USE THIS PRODUCT CORRECTLY AND
WITH CARE, FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY
CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY.

!

!

WARNING! Ensure Health and Safety, local authority and general workshop practice regulations 
are adhered to when using tools and equipment.

"

DO NOT

use calliper if damaged.

#

Maintain calliper in good and clean condition for best and safest performance.

#

Keep the work area clean, uncluttered and ensure there is adequate lighting.

#

Maintain correct balance and footing. Ensure the floor is not slippery and wear non-slip shoes.

#

Keep children and unauthorised persons away from the work area.

1.

SAFETY INSTRUCTIONS

2. INTRODUCTION & SPECIFICATION

Hardened and tempered stainless steel calliper with satin finish. 11mm High figures in LCD display for ease of
reading. Metric and Imperial calibration with conversion between the two. Zero setting control allows for
comparative measurement. Supplied in carry-case.

1

Internal Measure

2

Metric/Imperial Selector

3

Locking Screw

4

ABS/0 Switch

5 LCD Display
6

External Measure

7

On/Off Control

8

Zero Control

9

Battery Cover

10     Depth Measure
11     Step Measure

AK9622EV - (2) - 24/03/06

Specification:

Resolution . . . . . . . . . . . . . . . . . . . . . . . . . . 0.01mm (0.0005”)
Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200mm (8”)
Accuracy. . . . . . . . . . . . . . . . . ±0.02mm (±0.001”) @ <100mm

. . . . . . . . . . . . . . . . . . . . . . . . ±0.03mm (±0.001”) @ >100mm

Repeatability . . . . . . . . . . . . . . . . . . . . . . . . 0.01mm (0.0005”)
Functions . . . Zero set, mm/inch select, incremental zero, ABS
Messages . . . . . . . . . . . . . . Flashing display = replace battery 
Battery life . . . . . . . . . . . . . . . . . . . . . . . . . . Approx. two years 

. . . . . . . . . . . . . . . . . (approx. one year in continuous service)

Battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SR44 - 1.55V
Operational Temperature range . . . . . . . . . . . . . . . . . 5 - 40

O

C

Reviews: