background image

Operation Manual Version 1.4 - 940003846 – 27-10-20 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 
 

Isokern Celsius

 

Operating manual 
 

Schiedel Chimney Systems, Crowther Road, Crowther Industrial Estate 
Washington, Tyne & Wear NE38 0AQ 

 Tel. 0191 4161150 [email protected] 

 

 

 

Содержание Isokern Celsius

Страница 1: ...ion Manual Version 1 4 940003846 27 10 20 Isokern Celsius Operating manual Schiedel Chimney Systems Crowther Road Crowther Industrial Estate Washington Tyne Wear NE38 0AQ Tel 0191 4161150 info uk schiedel com ...

Страница 2: ...d Areas 4 Lighting the fire 6 Operation with door left open 7 Combustion 7 Faster or increased heat output 7 Increased burning time 7 Low firing 7 Maintenance of the fireplace insert 8 External cleaning 8 Service inspection 8 Operational issues 8 Smoke in the living room 8 Soot 9 Useful information 9 Type approval 9 Serial number 9 Vermiculite 9 Guarantee 10 CE Data Plate 11 Clean Air Act 12 The C...

Страница 3: ...tances that can damage the glass Fuel Overloading The maximum amount of fuel specified in this manual should not be exceeded overloading can cause excess smoke Refuelling on to a low fire bed If there is insufficient burning material in the firebed to light a new fuel charge excessive smoke emission can occur Refuelling must be carried out onto a sufficient quantity of glowing embers and ash that ...

Страница 4: ...ls appliance dampers or door left open except as directed in the instructions When using the appliance in a smoke controlled area the appliance must be set up with the combustion air control lever in place using the DEFRA settings DEFRA Compliance for Smoke Controlled Areas Unscrew the 4 screws on the cover plate ...

Страница 5: ...ing Manual 08 07 20 Page 5 Remove the cover plate Lift the top plate This will allow you to see the air control lever Adjust the air control lever so that the holes shown as Defra holes in the images below are the ones which will be secured ...

Страница 6: ... fire will burn down to glowing embers with no flame The door should be opened carefully so that smoke and ash are not released then redistribute the embers in a smooth layer covering the bottom of the insert up to the glass door Do not use printed matter or refuse to light the fire Add new logs and wait for approx 4 minutes the combustion air control lever above the door must be completely open a...

Страница 7: ...e ash is removed as needed Warning The ash can contain embers and therefore must be transported and stored in suitable containers 2 3 days prior to disposal via domestic waste Faster or increased heat output This is achieved by burning more small logs or sticks Increased burning time This is achieved if few larger pieces of wood are burned Remember sufficient air must always be supplied for the co...

Страница 8: ... to be expected as the steel plates on Celsius fireplace inserts are painted with a special heat resistant paint Therefore ventilate the room well the first few times the insert is used It is pointed out that there is no guarantee on glass and ceramic plates also in the case of cracks nor on glass fibre seals Operational issues The fireplace inserts are approved according to the EN standard which ...

Страница 9: ...le covered log store and with a maximum 18 moisture content Soot on the glass can be removed with glass cleaner or a piece of damp kitchen cloth dipped in ash Useful information Type approval The type approval is included in this installation and user guide which specifies the required distances to combustibles according to legal requirements etc Serial number The serial number is located on the t...

Страница 10: ...ion with warranty repair of service and care Labour costs involved in warranty repair The warranty is invalidated in the case of Damage caused by incorrect use Damage due to over firing Damage due to external factors and use of unsuitable fuels Failure to comply with statutory or recommended installation regulations or in case of alterations to the factory design of the insert Lack of service and ...

Страница 11: ... Page 11 Nominal Heat Output 6 7 Kw Recommended Chimney Draft 12 Pa Weight 90 Kg Smoke Departure X Ø150 Net Efficiency 83 Smoke gas mass flow 4 9 g s Temp 242 C PM Emission 3 mg m3 CO Emissions 0 082 OGC 58 mg m3 NOx 82 mg m3 Wood Capacity 7 6 kg CE Data Plate ...

Страница 12: ...de to sections 20 and 21 of the Clean Air Act 1993 by section 15 of the Deregulation Act 2015 Similarly in Scotland appliances are exempted by publication on a list by Scottish Ministers under section 50 of the Regulatory Reform Scotland Act 2014 In Wales and Northern Ireland these are authorised by regulations made by Welsh Ministers and by the Department of the Environment respectively Further i...

Страница 13: ...ance and the maximum levels of emissions permitted These new Ecodesign Regulations represent a significant tightening of these criteria over the current CE requirements DEFRA exempt In addition to meeting the requirements of Ecodesign for efficiency and emissions all clearSkies certified appliances at Level 3 or above will also have been verified by the scheme administrator as meeting the requirem...

Страница 14: ...Celsius Operating Manual Celsius Operating Manual 08 07 20 Page 14 INSERT DIMENSIONS ...

Страница 15: ...Celsius Operating Manual Celsius Operating Manual 08 07 20 Page 15 ...

Страница 16: ...Schiedel Chimney Systems Ltd Unit 8 9 Block A Holton Road Holton Heath Industrial Estate Poole Dorset BH16 6LG Tel 44 0 1202 861650 sales uk schiedel com www schiedel com uk ...

Отзывы: