background image

 

 

Leading Image Processing Technology 

We've been there when you needed 

 

 

 

    SB1000    / SB-1100 

Currency Discrimination Counter 

 

 

 

 

 

 

 

 

SBM Co., Ltd. 

6F, Hyunwoo Bldg., 206, Anyang7-Dong, Manan-Gu, Anyang-City, Gyeonggi-Do, Korea 430-817 

Summary of Contents for SB-1100

Page 1: ...ading Image Processing Technology We ve been there when you needed SB1000 SB 1100 Currency Discrimination Counter SBM Co Ltd 6F Hyunwoo Bldg 206 Anyang7 Dong Manan Gu Anyang City Gyeonggi Do Korea 430 817 ...

Page 2: ... soft cloth slightly dampened with water Do not use aerosol cleaners Gas Leaks Never use any machine close to a gas leak If you think gas is leaking call the gas company immediately A small electrical spark in the machine could cause a fire or explosion Precaution When using the machine these precautions should always be followed 1 Never push objects of any kind into your machine through the case ...

Page 3: ...re operating your machine and refer to them as needed to ensure the continued safe operation of your machine Battery is used for PBA IMAGE in this machine If wrong date and time are displayed on LCD after correct setting it is necessary to change the battery of PBA IMAGE Please read the following instructions carefully before changing the battery Warning Hazardous moving parts Keep fingers and oth...

Page 4: ...nction 15 Changing Display Contents 16 Grand Total 18 Selecting Currency 19 Chapter 7 Set Function and its Parameters 20 Function Main Menu 19 Set Speed of the Machine 21 Set Contrast of Banknotes 22 Set Auto Start Mode Mode Lock Function 22 Set Beep Function 23 Set Pocket Capacity 23 Setup Interface and Print results 24 Set Banknote Criteria 25 Set Parameters 25 Settings 26 Currency Mode Change 2...

Page 5: ...connecting a printer option 1 pc Choosing a Location To help guarantee trouble free operation of your machine place it on a flat stable surface near your workstation Do not place your machine In direct sunlight Near heat sources or air conditioners In dusty or dirty environments Handling the Machine When handling or moving the machine do not lift with grasping the Reject Pocket The picture shows h...

Page 6: ...mber saved by a service provider the Call number will be displayed as below Printer Your SB1000 SB 1100 has a serial interface port which allows you to connect the printer to print out counting result To connect the printer to the machine follow the steps below 1 Make sure that both the SB1000 SB 1100 and the printer are turned off 2 Plug the cable of printer into the serial port of SB1000 SB 1100...

Page 7: ...6 Description of the Parts Front View Rear View Remark The Parallel Connector is an optional item ...

Page 8: ...ece Large View Amount Detail View Piece Large View Piece Detail View Reject Reason 2 HYPHEN key in some input mode MODE 1 Change Mode Mixed Single Sort Facing Orientation Count Option Serial no Printing SRL P OCR B CODE and B MIXED 2 LEFT key in some input mode GT 1 Grand Total Display 2 RIGHT key in some input mode Up Down FUNCTION Change Values of various Parameters START ENTER Counting Start EN...

Page 9: ...8 Overview of Display LCD ...

Page 10: ...ine Counting In AUTO mode the machine starts to count the bill automatically as it detects the existence of the bill in the hopper In MANUAL mode the machine will start to count the bill only if the bills are placed into the hopper and START key is pressed While counting the machine will display the number of the bills on LCD display and it stops working when it meets the conditions described as b...

Page 11: ...tomatically but if it fails to clear a jam or there are some other mechanical errors open the front or rear cover and get rid of jammed bills and close the cover correctly Then press the CLEAR key again to clear error message Especially in case of JAM3 it is recommended to open the front cover and to check the machine before pressing CLEAR key Stop in operation Press START button to stop operation...

Page 12: ...tacker If a note fails to be detected or it is a counterfeit suspect if CF mode is ON the note will be sent to the reject pocket To change into the MIXED mode press MODE key until MIXED is displayed on LCD Single mode SINGL mode In Single mode when the machine reads a note whose denomination is same as the first denomination of note counted or the pre set denomination while counting and discrimina...

Page 13: ...RT mode In SORT mode the machine allows you to count and sort stacks of mixed denomination notes into straps and verify deposits Each time machine begins processing of a new stack of notes it automatically starts counting denomination of the first note fed from the hopper When a note of a different denomination from the first denomination is detected machine stops with the error message CHANGE OF ...

Page 14: ... find out information regarding denomination direction and face Then it sorts the notes with the information If a note has same denomination face and direction it will be sent to the output Stacker Pocket Otherwise it will be sent to the Reject Pocket Other operation is as same as SINGL mode operation with D D condition except that the machine sorts by direction and face The machine will try to fi...

Page 15: ...ode press MODE key until P OCR is displayed on LCD B CODE and B MIXED mode In B CODE Mode machine reads bar code printed on casino tickets and sends image data to an attached printer SBM configured Thermal Printer or to your PC application software In B MIXED mode the machine reads bar coded tickets and banknotes at one pass and sends bar code information as image to the printer or to your PC soft...

Page 16: ...f by pressing ADD key ADD Function in all other modes Mixed Sort Face Orent When ADD is on SB1000 SB 1100 will accumulate each running total in all of these modes and save them to memory Each of these running totals will be added automatically and carry over to the next count when modes are changed For example a running total in Mixed mode can be carried over to the running total in Sort mode Tota...

Page 17: ...ctivation of denomination batch function If DB is selected machine will count and batch the desired denomination by pre set batch number For further information on how to set up DB Denomination Batch setting please refer to Chapter 7 Set Function and its Parameters Settings Changing Display Contents The machine provides various information regarding counting results Every time pressing DISPLAY key...

Page 18: ...e shows that several notes were rejected The first note from the bottom of the Reject Pocket was rejected by the reason of NO I D and the second note was rejected by the reason of SUSPECT etc The Down arrow in the picture means that there are more lists and you can see the rest lists by pressing DOWN key ...

Page 19: ...ke below pictures every time when GT key is pressed Only in this display mode the operator can clear grand total by pressing CLEAR key If the grand total is cleared the printing sequence number is automatically reset to 1 To exit from the grand total display mode just press DISPLAY or just start another counting job Grand Total View Summary of the Reject Reasons NO I D The machine failed to identi...

Page 20: ...then by pressing FUNC key 0 numeric key the currency mode can be changed sequentially If you need more software to handle different currencies please consult with your dealer for purchasing the software See also Ch 7 Set Function and its Parameters Currency Mode Change Caution GT function will not be activated if ADD key is on Please turn off the ADD function to use GT function If the currency mod...

Page 21: ...key to enter Or you can directly move to a menu by just pressing a numeric key For example to move to the BEEP menu press DOWN key two times and press START or just press numeric 3 key Then a sub menu will be displayed and you can set a value or ON OFF condition To escape from the menu completely press CLEAR ESC key or to continue to set up press FUNCTION key again in sub menu mode The factory def...

Page 22: ... offers with three speeds 800 1000 1200 NPM Notes per Minute In sub menu press a numeric key to select a speed or you can select using UP DOWN key and START key In COUNT mode you can set the speed up to 1200NPM but in SINGL FACE ORENT or MIXED modes the machine works with maximum 750 NPM Please refer to the below table to see the compulsory maximum speed for each condition Mode Compulsory Maximum ...

Page 23: ...achine starts to count automatically when detecting a note on the hopper Whereas in Manual mode the machine starts to count after a note is placed in the Hopper and START ENTER is pressed This mode is displayed on LCD like below To change the mode move to START MODE SET and press ENTER key or directly press the numeric 3 key And then select an option in the sub menu If AUTO START is selected the D...

Page 24: ...he capacity of the Reject Pocket and the Stacker Pocket is changeable using this function If a user normally processes good quality notes then the capacity of the Reject Pocket and the Stacking Pocket can be set to maximum 70 notes and 200 notes respectively otherwise the value should be set to minimum 30 notes for the Reject Pocket and 100 notes for the Stacking Pocket To set to a value moves to ...

Page 25: ...rs like below Speed Baud Rate 9600 bps Parity None Data Bit 8 Stop Bit 1 The parameters of a printer should be set to as same value as the above description The Column Length parameter is to be set to the column length of the printer To print the result press and hold START key for more than 1 second after the machine finished counting To print the Grand Total press and hold START key for more tha...

Page 26: ...then change the value to higher level and try again until proper value is reached In case of MR sensor on SB1000 model there are only three levels to choose from As for SB 1100 model user can choose MR counterfeit level from 1 15 To set a certain level select BANKNOTES CRITERIA and press ENTER key Then choose one of the sensors by pressing UP DOWN key or a numeric key and select a certain level yo...

Page 27: ...UP DOWN key and press START key then a new window will be open Input date and time using the numeric keys and MODE or GT key To save the change press START key Station ID Set Select Station ID Set using UP DOWN key and press START key to enter Using UP DOWN key input station ID of the machine and then press START key to save the change Settings Denomination Batch Setting DB can also be set under t...

Page 28: ...27 Currency Mode Change If multiple currencies software is purchased with SB1000 SB 1100 then every time when FUNC key 0 key is pressed the currency mode can be changed recursively ...

Page 29: ...nsor JAM2 Jam Error near JP sensor JAM3 Jam Error near SP sensor Notes Please refer to the figures on Chapter 9 to see the position of the sensors Fixing Problems FRONT COPEN 1 Press Front Cover until it clicks in place 2 Press CLEAR HOPPER EXIST 1 Remove the banknotes on the Hopper 2 Press CLEAR MAIN MOTOR SKEW DOUBLE MFEED JAM0 JAM1 JAM2 and JAM3 1 Remove banknotes on the Hopper 2 Press CLEAR Ca...

Page 30: ...nsors are very sensitive and if they are not cleaned correctly everyday this may negatively affect performance of the machine Note that only SB 1100 model is equipped with IR Sensors as shown below Clean the sensors described below everyday after operating The power must be turned off before cleaning and please do not use a volatile solvent for cleaning Inside of the Machine Front Cover Open ...

Page 31: ...oto sensors the rollers and the scanning glass once a day If excess dust is allowed to accumulate the recognition rate can be lower than expected 1 Open the rear cover 2 Clean inside of the rear cover 3 Carefully wipe the scanning glass with a soft dry cloth If the glass is very dirty first wipe it with a slightly dampened cloth with alcohol then with a dry cloth Be very careful not to scratch the...

Page 32: ...m W 100 185 H 60 90 Banknote thickness range mm 0 08 0 12 Counting Speed Notes min 800 1000 1200 Discrimination Mode MIXED SINGL SORT FACE ORENT COUNT Optional P OCR B CODE B MIX SRL Preset Batch Number 1 200 Counterfeit Detection MG SB1000 UV SB1000 1ch SB 1100 3ch MR Array SB 1100 IR SB 1100 Power Requirements 90 240VAC 50 60Hz Power Consumption W Standby 9 Operation 70 Operational requirements ...

Reviews: