Document 27-667

 │ Release ENG

01

 │ 

2019-08-14

User Manual

Q.NET-5TX and Q-NET-8TX

Industrial Ethernet Rail Switch

Summary of Contents for Q.NET-5TX

Page 1: ...Document 27 667 Release ENG01 2019 08 14 User Manual Q NET 5TX and Q NET 8TX Industrial Ethernet Rail Switch ...

Page 2: ... voltage 1 4 1 11 CE marking 1 4 1 12 FCC note 1 5 1 13 Recycling note 1 5 2 Description 2 1 General device description 2 1 2 2 Device name and product code 2 1 2 3 Device view 2 2 2 3 1 Q NET 5TX 2 2 2 3 2 Q NET 8TX 2 3 2 4 Power supply 2 3 2 5 Ethernet ports 2 4 2 5 1 10 100 Mbit s twisted pair port 2 4 2 6 Pin assignments 2 4 2 7 Display elements 2 5 2 7 1 Device state 2 5 2 7 2 Port state 2 6 ...

Page 3: ...he device 6 1 7 Technical data 7 1 General technical data 7 1 7 2 Dimension drawings 7 2 7 2 1 Q NET 5TX 7 2 7 2 2 Q NET 8TX 7 2 7 3 EMC and immunity 7 3 7 4 Network range 7 3 7 5 Power consumption power output at 24 V DC 7 4 7 6 Scope of delivery 7 4 7 7 Underlying technical standards 7 4 A Appendix A 1 Icons A 1 A 2 Contact A 2 ...

Page 4: ...chen Content 0 0 1 Document history Version Published Chapter Remarks ENG01 2019 08 14 all First edition 0 2 Trademarks Saia PCD is a registered trademark of Saia Burgess Controls AG Subject to technical changes in line with the latest technological developments Saia Burgess Controls AG 2019 All rights reserved Published in Switzerland ...

Page 5: ...f the supply voltage and return the device to Hirschmann for inspection 1 2 Certified usage Use the product only for the application cases described in the Hirschmann product information including this manual Operate the product only according to the technical specifications See 7 Technical data auf Seite 7 1 Connect to the product only components suitable for the requirements of the specific appl...

Page 6: ...f f Qualified personnel are familiar with appropriate measures against these haz ards in order to reduce the risk for themselves and others f f Qualified personnel receive training on a regular basis 1 6 National and international safety regulations Verify that the electrical installation meets local or nationally applicable safety regulations 1 7 Grounding the device The device is grounded by mea...

Page 7: ...sily accessible disconnecting device e g a switch or a plug This disconnecting device is clearly identified So in the case of an emergency it is clear which disconnecting device belongs to which power supply cable f f The power supply cable is suitable for the voltage the current and the physical load SBC recommends a wire diameter of 0 5 mm AWG20 f f The cross section of the ground conductor is t...

Page 8: ... lations of member states with regard to electromagnetic compatibility In accordance with the above named EU directive s the EU conformity declara tion will be available to the relevant authorities at the following address Hirschmann Automation and Control GmbH Stuttgarter Str 45 51 72654 Neckartenzlingen Deutschland Tel 49 1805 141538 The device can be used in the industrial sector f f Interferen...

Page 9: ...ent protection against interfer ence when the device is being used in a business environment The device creates and uses high frequencies and can also radiate these frequen cies If it is not installed and used in accordance with this operating manual it can cause radio transmission interference The use of this device in a residential area can also cause interference and in this case the user is ob...

Page 10: ...ility even under extreme conditions and also long term reliability and flexibility You have numerous options of combining the device characteristics 2 2 Device name and product code The device name corresponds to the product code The product code is made up of characteristics with defined positions The characteristic values stand for spe cific product properties Code Characteristic value Descripti...

Page 11: ...9 08 14 2 2 2 Device view Description 2 3 Device view 2 3 1 Q NET 5TX 1 2 3 4 5 6 7 8 1 LED display elements for device status 2 3 pin pluggable terminal block for power supply 3 7 5 RJ45 socket for 10 100 1000 Mbit s Twisted Pair connections 8 Rail lock gate for DIN rail mounting ...

Page 12: ...6 4 RJ45 socket for 10 100 Mbit s twisted pair connections 7 Rail lock gate for DIN rail mounting 8 11 4 RJ45 socket for 10 100 Mbit s twisted pair connections 2 4 Power supply You have the following options to supply your device with voltage Power supply via a 3 pin terminal block For the power supply of the device a 3 pin terminal block is available For further information see 3 3 Wiring the ter...

Page 13: ...ort offers you the ability to connect network com ponents according to the IEEE 802 3 10BASE T 100BASE TX standard This port supports f f Autonegotiation f f Autopolarity f f Autocrossing f f 100 Mbit s half duplex mode 100 Mbit s full duplex mode f f 10 Mbit s half duplex mode 10 Mbit s full duplex mode 2 6 Pin assignments RJ45 Pin 10 100 Mbit s 1 2 3 4 5 6 7 8 MDI mode 1 TX 2 TX 3 RX 4 5 6 RX 7 ...

Page 14: ...er the supply voltage is switched on the device performs a self test During this process various LEDs light up 2 7 1 Device state This LED provides information on the status of the power supply Color Activity Meaning Green Lights up Supply voltage is on Device is ready for operation None Supply voltage is too low Device is not ready for operation ...

Page 15: ...en Lights up Device detects a valid link Flashing Device is transmitting and or receiving data None Device detects an invalid or missing link SP Color Activity Meaning data rate Yellow Flashes 1 time a period 10 Mbit s connection Flashes 2 times a period 100 Mbit s connection Flashes 3 times a period 1000 Mbit s connection 100 Mbit s Color Activity Meaning Yellow Lights up 100 Mbit s connection No...

Page 16: ...elivery the device is ready for operation To configure a subdomain follow these steps f f Checking the package contents f f Mounting the device f f Wiring the terminal block for the supply voltage and the grounding f f Operating the device f f Connecting data cables 3 1 Checking the package contents Check whether the package includes all items named in the section 7 6 Scope of delivery auf Seite 7...

Page 17: ...ce f f Installing the device onto the DIN rail f f Mounting on a flat surface 3 2 1 Installing the device onto the DIN rail Prerequisite The device is for mounting on a 35 mm DIN rail in accordance with DIN EN60715 2 1 Proceed as follows Slide the upper snap in guide of the device into the DIN rail Use a screwdriver to pull the rail lock gate downwards Snap in the device by releasing the rail lock...

Page 18: ...n via protective elements The shielding ground of the connectable twisted pair cables is connected to the ground connection as a conductor 24 V 0 V Figure 1 3 pin pluggable terminal block for power supply and grounding Type of the voltages that can be connected Specification of the supply voltage Connections Gleichspannung Nennspannungsbereich DC 12 V 24 V Spannungsbereich DC inklusive maximaler T...

Page 19: ...or the data transmission between the buildings f f When using copper cables provide a sufficient separation between the power supply cables and the data cables Ideally install the cables in separate cable channels f f Verify that power supply cables and data cables do not run parallel over longer distances and that ideally they are installed in separate cable channels If re ducing the inductive co...

Page 20: ...Operate the device below the specified maximum ambient air temperature exclu sively See 7 1 General technical data auf Seite 7 1 The ambient air temperature is the temperature of the air at a distance of 2 in 5 cm from the device It depends on the installation conditions of the device e g the distance from other devices or other objects and the output of neighboring devices ...

Page 21: ...operated normally Operate this device according to the specifications Depending on the degree of pollution in the operating environment check at regu lar intervals that the ventilation slots in the device are not obstructed CAUTION RISK OF TRANSIENTS OR ELECTROSTATIC DISCHARGES Do not open the housing Failure to follow these instructions can result in injury or equipment damage Note You will find ...

Page 22: ...Removing the device Disassembly 6 Disassembly 6 1 Removing the device 1 2 Proceed as follows Disconnect the data cables Disable the supply voltage Remove the power connector from the device Use a screwdriver to pull the rail lock gate downwards Pull the device downwards from the DIN rail module ...

Page 23: ...4 V DC Back up fuse 4 A slow blow Peak inrush current 4 A Potential differ ence between input voltage and ground connection Potential difference from incoming volt age 24 V DC 32 V DC Potential difference from incoming volt age ground 32 V DC Climatic conditions during operation Ambient air temperaturea 0 C 60 C Derating Humidity 10 95 non condensing Air pressure minimum 795 hPa 6562 ft 2000 m Cli...

Page 24: ...s Controls AG User Manual Q NET xTX Document 27 667 Release ENG01 2019 08 14 7 2 7 Dimension drawings Technical data 7 2 Dimension drawings 7 2 1 Q NET 5TX 100 118 3 73 6 26 15 7 2 2 Q NET 8TX 100 118 3 73 6 38 15 ...

Page 25: ...arge 8 kV Electromagnetic field EN 61000 4 3 80 MHz 1000 MHz 10 V m Fast transients burst EN 61000 4 4 IEEE C37 90 1 DC supply connection 2 kV EN 61000 4 4 IEEE C37 90 1 Data line 4 kV Voltage surges DC supply connection EN 61000 4 5 line ground 2 kV EN 61000 4 5 line line 1 kV Voltage surges data line EN 61000 4 5 line ground 1 kV Conducted disturbances EN 61000 4 6 150 kHz 80 MHz 10 V Stability ...

Page 26: ... Products EN 55022 Information technology equipment Radio disturbance characteristics Limits and methods of measurement EN 60950 1 Information technology equipment Safety Part 1 General requirements EN 61000 6 2 Electromagnetic compatibility EMC Part 6 2 Generic standards Immunity for industrial environments EN 61131 2 Programmable controllers Part 2 Equipment requirements and tests FCC 47 CFR Par...

Page 27: ...th this symbol must always be followed This symbol warns the reader of the risk to components from electrostatic discharges caused by touch Recommendation Before coming into contact with electrical components you should at least touch the Minus of the system cabinet of PGU connector It is better to use a grounding wrist strap with its cable permanently attached to the Minus of the system Explanati...

Page 28: ...e 18 3280 Murten Switzerland Telefon 41 265803000 Fax 41 265803499 Email Support support saia pcd com Supportsite www sbc support com SBC site www saia pcd com International Represetatives SBC Sales Companies www saia pcd com contact Postal address for returns from customers of the Swiss Sales office Saia Burgess Controls AG Service Après Vente Bahnhofstrasse 18 3280 Murten Switzerland ...