OPTICAL-ACOUSTIC 

OUTDOOR SIREN 

SP-4002

 

 

sp4002_en 12/09 

The SP-4002 optical-acoustic outdoor siren comes in three versions differing by the color of optical 
signaling (red in SP-4002 R, blue in SP-4002 BL and orange in SP-4002 O). 

1. Features 

  Acoustic signaling by means of piezoelectric transducer. 

  Optical signaling by means of LEDs. 

  Battery as backup power supply. 

  Four selectable tones for acoustic signaling. 

  Weatherproofed electronic circuit. 

  Tamper protection in 2 ways – cover opening or tearing housing from the wall. 

  Inner cover of galvanized metal sheet. 

  Housing made of PC LEXAN high-impact polycarbonate, featuring a very high mechanical 

strength. 

 
Explanations for Fig. 1: 
1 -  housing cover. 
2 - inner cover of galvanized 

sheet. 

3 -  housing base. 
4 -  battery. 
5 -  piezoelectric transducer. 
6  -  tamper contact (NC). 
7 -  electronics board. 
8 -  housing 

cover 

locking 

screws. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

Fig. 1. View of the siren. 

 

2. Functioning 

The siren requires 12 V ±15% power supply. The signaling is generated by changing the STA input 
status (acoustic signaling) or the STO input status (optical signaling). The way of triggering the alarm 
is set by means of the PLA and PLO pins. The alarm can only be triggered 20 seconds after power-
up, provided that during that time the signaling control input status was stable and consistent with that 

Summary of Contents for SP-4002

Page 1: ...ized metal sheet Housing made of PC LEXAN high impact polycarbonate featuring a very high mechanical strength Explanations for Fig 1 1 housing cover 2 inner cover of galvanized sheet 3 housing base 4 battery 5 piezoelectric transducer 6 tamper contact NC 7 electronics board 8 housing cover locking screws Fig 1 View of the siren 2 Functioning The siren requires 12 V 15 power supply The signaling is...

Page 2: ... acid battery but it can also work without one Notes The battery charging system used in the siren is designed for recharging a partially discharged battery not for charging a fully discharged one The current consumed by the siren to charge the battery depends on the battery degree of discharge 3 Description of electronics board TMP TMP GND STO STA SENS TMP 12V BUZZ ML0 ML1 TM0 TM1 PLA PLO O A LED...

Page 3: ... cut off inactive status common ground present on STA input PLA On 12 V voltage loss inactive status 12 V present on STA input Way of triggering optical alarm polarization of STO input PLO On common ground cut off inactive status common ground present on STO input PLO On 12 V voltage loss inactive status 12 V present on STO input 5 Installation Install the siren on flat surface in a hard to reach ...

Page 4: ...t consumption optical signaling 60 mA acoustic signaling 240 mA optical and acoustic signaling 260 mA Internal lead acid battery 6 V 1 3 Ah Sound pressure level at 1 m distance up to 120 dB Environmental class according to EN50130 5 III Operating temperature range 35 55 C Maximum humidity 93 3 Housing dimensions 148 x 254 x 64 mm Weight 1 2 kg SATEL sp z o o ul Schuberta 79 80 172 Gdańsk POLAND te...

Reviews: