background image

®

 

VOICE SYNTHESISER EXPANDER 

CA-64 SM

 

ca64sm_en 03/10 

The CA-64 SM voice synthesizers expander is designed to operate in intruder alarm 
systems. It is supported by the CA-64, INTEGRA and VERSA alarm control panels 
manufactured by the SATEL company. It enables recording up to 16 voice messages which 
may be used by the alarm control panel for telephone messaging. The maximum message 
duration is 15 seconds. 

1.  Description of the electronics board 

 

 

Fig. 1. View of the expander electronics board. 

 
Explanations for Fig. 1: 
1 - a set of DIP-switches for setting individual address of the module and for 

disabling/enabling the message recording (see section DIP-

SWITCHES

). 

2  -  SYSTEM LED indicating communication with the control panel: 

  LED is blinking – data exchange with the control panel; 

  LED is lit – no communication with the control panel. 

3  -  LEDs to provide information on voice messages: 

  M3, M2, M1, M0 – present the number of recorded / played back message in binary 

format (see Table 1); 

  REC – lit when the message is being recorded; 

  PLAY – lit when the message is being played back. 

4  -  expander control buttons: 

  REC – recording the message; 

  PLAY – playing back the message; 

  MSG. NO – selecting the message number. 

5  -  cables for connecting the expander to the communication bus. 

Summary of Contents for CA-64 SM

Page 1: ...set of DIP switches for setting individual address of the module and for disabling enabling the message recording see section DIP SWITCHES 2 SYSTEM LED indicating communication with the control panel LED is blinking data exchange with the control panel LED is lit no communication with the control panel 3 LEDs to provide information on voice messages M3 M2 M1 M0 present the number of recorded playe...

Page 2: ...LED ON 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Table 1 The way of message number presentation 1 1 DIP switches The DIP switches from 1 to 5 are to be used for address setting The address must be different from that of the other modules connected to the communication bus of alarm control panel In order to determine the expander address add up the values set on individual switches as shown in Table 2 DIP ...

Page 3: ...IP switches set the expander address 5 Turn on power supply of the alarm system 6 Start the identification function in the control panel 2 1 Recording the voice messages 1 Set the DIP switch 8 into the ON position 2 Press the MSG NO button to select the number of message to be recorded The message number is displayed by means of LEDs as shown in Table 1 3 Press the REC button the REC LED will go o...

Page 4: ...he PLAY button the PLAY LED will go on The message will be played back 3 Technical data Number of stored voice messages 16 Maximum message duration 15 s Supply voltage 12 V DC 15 Maximum current consumption 65 mA Dimensions of electronics board 57x80 mm Weight 41 g The latest EC declaration of conformity and product approval certificates are available for downloading on website www satel pl SATEL ...

Reviews: