ZONE EXPANDER WITH POWER SUPPLY

CA-64 EPS

 

ca64eps_en 06/09 

The CA-64 EPS zone expander is designed for operation in the intruder alarm systems. It 
can work in conjunction with the SATEL made CA-64, INTEGRA and VERSA alarm control 
panels. It enables the alarm system to be expanded by additional 8 zones. The expander 
zones can be programmed as NO, NC, EOL, 2EOL/NO or 2EOL/NC. The value of resistors 
in EOL and 2EOL configurations is programmable. The expander can support vibration and 
roller shutter motion detectors. The module has a built-in switching-mode power supply of 1.2 
A capacity. It also has battery charging circuit and testing circuit with disconnection of 
discharged battery. This manual applies to the expander with electronics version 2.0 and 
firmware version 2.0 (or newer). 

1.  Description of electronics board 

 

ADRES
12345

STATUS

COM

Z1

Z2

Z3 COM Z4

Z5 COM Z6

Z7 COM Z8 TMP CLK DTA +12V+12V COM COM AC

AC

350mA
700mA

1

2

3

4

 

Fig. 1. Schematic view of the expander electronics board. 

 
Explanations to Figure: 
1 – 

a set of DIP-switches

 for setting individual address of the module and defining how the 

expander will be identified and, consequently, what functions will be available (see 
DIP-

SWITCHES

). 

2 – 

LED STATUS

 to indicate the process of communication between control panel and 

expander: 

  LED is blinking – data exchange with the panel; 

  LED is lit – no communication with the control panel. 

3 – 

pins

 to set up the battery charging current: 

  pins shorted – 350 mA 

  pins open – 700 mA 

Summary of Contents for CA-64 EPS

Page 1: ...ing circuit with disconnection of discharged battery This manual applies to the expander with electronics version 2 0 and firmware version 2 0 or newer 1 Description of electronics board ADRES 12345 STATUS COM Z1 Z2 Z3 COM Z4 Z5 COM Z6 Z7 COM Z8 TMP CLK DTA 12V 12V COM COM AC AC 350mA 700mA 1 2 3 4 Fig 1 Schematic view of the expander electronics board Explanations to Figure 1 a set of DIP switche...

Page 2: ...f interaction with the VERSA control panel an address from the 12 0Ch to 14 0Eh range must be set In order to determine the expander address add up the values set on individual switches as shown in Table 1 DIP switch number 1 2 3 4 5 Numerical value for switch in ON position 1 2 4 8 16 Table 1 The switches 6 and 7 must be set to OFF position Position of the switch 8 affects the way of expander ide...

Page 3: ... supply circuit should be protected with a proper safety device Let the owner user of the security system to know how the transformer should be disconnected from the mains supply e g by indicating the fuse which protects the control panel supply circuit A 12 V lead acid sealed battery should be connected to the control panel as an emergency power source Note If the battery voltage drops below 11 V...

Page 4: ...e identification function in the control panel When the identification is completed the zones will be assigned respective numbers in the alarm system zone numeration rules are described in the alarm control panel manual 3 Specifications Supply voltage 18 V AC 10 50 60 Hz Number of programmable zones 8 Power supply output voltage 13 6 V 13 8 V DC Battery failure voltage threshold 11 V 10 Battery cu...

Reviews: