background image

 

 

 

 

 

 

 

 

 

 

 

 

EXPAND SERIAL COMMAND

 

FUNCTIONAL SPECIFICATIONS 

 

PLC-ET30L

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SANYO Electric Co., Ltd 

Personal Mobile Group 

DI Company 

Projector Division 

 

 

 

Summary of Contents for PLC-ET30L

Page 1: ...EXPAND SERIAL COMMAND FUNCTIONAL SPECIFICATIONS PLC ET30L SANYO Electric Co Ltd Personal Mobile Group DI Company Projector Division ...

Page 2: ...and Table 12 6 1 Image Status Read Command Table 12 6 2 PC Adjust Status Read Command Table 12 6 3 Video Status Read Command Table 12 6 4 Input Status Read Command Table 12 6 5 Screen Status Read Command Table 13 6 6 Lamp Status Read Command Table 13 6 7 Sound Status Read Command Table 13 6 8 Setting Status Read Command Table 13 6 9 Other Status Read Command Table 14 7 Error Code Table 14 8 Functi...

Page 3: ... 23 8 5 11 CF_PCMODEFREE Command 23 8 6 Input Control Command 24 8 6 1 CF_INPUT Command 24 8 6 2 CF_SOURCE Command 24 8 6 3 CF_INPUT 1 Command 25 8 6 4 CF_INPUT 2 Command 25 8 6 5 CF_INPUT 3 Command 25 8 6 6 CF_INPUT 4 Command 25 8 6 7 CF_SYSTEM Command 26 8 7 Screen Control Command 27 8 7 1 CF_SCREEN Command 27 8 7 2 CF_DZCENT Command 27 8 7 3 CF_KEYSTONE Command 27 8 7 4 CF_KYSTNMODE Command 28 ...

Page 4: ...mmand 35 8 10 16 CF_FDEFAULT Command 35 8 10 17 CF_PJPINCODE Command 35 8 10 18 CF_TESTPAT Command 35 8 10 19 CF_FILH Command 36 8 10 20 CF_FILTIMER Command 36 8 10 21 CF_POINTER Command 36 8 11 Other Commands 36 8 11 1 CF_KEYEMU Command 36 8 11 2 CF_MENU Command 37 8 11 3 CF_POWER Command 37 8 11 4 CF_FREEZE Command 37 9 Status Read Command 38 9 1 Format 38 9 2 Transfer Example 38 9 3 Operation C...

Page 5: ... Command 44 9 6 Video Status Read Command 45 9 6 1 CR_SERSYS Command 45 9 7 Input Read Command 45 9 7 1 CR_INPUT Command 45 9 7 2 CR_SOURCE Command 45 9 7 3 CR_SRCINP1 Command 46 9 7 4 CR_SRCINP2 Command 46 9 7 5 CR_SRCINP3 Command 46 9 7 6 CR_SRCINP4 Command 46 9 7 7 CR_SYSTEM Command 47 9 7 8 CR_SYSLIST Command 48 9 7 9 CR_MODELIST Command 48 9 7 10 CR_HMSLOT Command 49 9 7 11 CR_NMSLOT1 Command...

Page 6: ...d Command 54 9 11 1 CR_BACKGND Command 54 9 11 2 CR_DISP Command 54 9 11 3 CR_LOGO Command 54 9 11 4 CR_LOGOLOCK Command 55 9 11 5 CR_CEIL Command 55 9 11 6 CR_REAR Command 55 9 11 7 CR_RCODE Command 55 9 11 8 CR_RCSENSOR Command 55 9 11 9 CR_RTYPE Command 56 9 11 10 CR_LANG Command 56 9 11 11 CR_ON STA Command 56 9 11 12 CR_P MANE Command 56 9 11 13 CR_P MANETIME Command 57 9 11 14 CR_FANSPEED Co...

Page 7: ... 9 11 25 CR_FILTIMER Command 59 9 11 26 CR_POINTER Command 59 9 12 Other Status Read Commands 60 9 12 1 CR_STATUS Command 60 9 12 2 CR_SIGNAL Command 60 9 12 3 CR_VMUTE Command 60 9 12 4 CR_FREEZE Command 60 9 12 5 CR_TEMPFAIL Command 61 9 12 6 CR_TEMP Command 62 ...

Page 8: ...h RS 232C Therefore commands in this document are defined as Expand Serial Commands 2 Serial Interface Specification 2 1 Transfer Specification Item Specification Synchronous System Asynchronous Transmission Speed 9600 19200 Data Length 8 bits Parity N A Stop Bit 1 Flow Control N A Note1 Transmission Speed initial setting value is 19200 Note2 Transmission Speed can be changed in Service mode 2 2 C...

Page 9: ... Projector CF_BRIGHT_032 CR Next command Projector PC 000 CR Return Value A few ms 5s Do not send another command before the reception of the return value the operation by the commond is not ensured However this is not the case when no response is returned after more than 5 seconds It takes about 5 seconds for internal initialization after plugging in AC power During this time it cannot process co...

Page 10: ... 1 CR Set value of Vertical Position CF_DDOTS_ 1 CR Set value of Display Dots CF_DLINE_ 1 CR Set value of Display Line CF_SETPCADJ_ 1 CR Apply values set in PC Adjust menu to screen image CF_ORGMODE_ 1 CR Specify the original signal for PC mode CF_PCSTORE_ 1 CR Store current setting values in PC Adjust menu to Mode 1 CF_PCMODEFREE_ 1 CR Delete the values registered in Mode 1 and return it to Free ...

Page 11: ... remote control CF_LANG_ 1 CR Select language for OSD CF_ON STA_ 1 CR Set ON OFF of Power ON Start CF_P MANE_ 1 CR Set Power Management function CF_P MANETIME_ 1 CR Set time of Power Management CF_FANSPEED_ 1 CR Set level of Fan Speed CF_HIGHLAND_ 1 CR Set Highland mode CF_SLANT_ 1 CR Set slant of projector installed CF_KEYDIS_ 1 CR Prohibit RC KEY control CF_FDEFAULT_ 1 CR Reset to Factory Defaul...

Page 12: ...ertical Position CR_DDOTS CR Get setting value of Display Dots CR_DLINE CR Get setting value of Display Line CR_ORGMODE CR Get the original signal for PC Adjusted mode CR_PCSTORE CR Get status Free Stored for PC Adj mode 1 10 CR_SETPCADJ CR Get currently displayed PC signal in system 6 3 Video Status Read Command Table Status Read command Item CR_SERSYS CR Get currently selected signal In Auto mod...

Page 13: ... CR Get setting status of Screen for no signal CR_DISP CR Get setting status of Display CR_LOGO CR Get setting status of Logo CR_LOGOLOCK CR Get setting status of Logo Lock CR_CEIL CR Get setting status of Ceiling CR_REAR CR Get setting status of Rear CR_RCODE CR Get selected Remote Control code CR_RCSENSOR CR Get setting status of Remote Control Sensor Enable Disable CR_RTYPE CR Get supported Rem...

Page 14: ...tents When the received data cannot be decoded Parameter decignation error wrong digit number including invalid value etc 000 Normal reception This is Not error 102 Directly specified value or values are out of range Not reflected 103 Command mismatched to Hardware the command is for Optional function which is not implemented 201 Incremented or decremented value or values are beyond upper or lower...

Page 15: ...l command PC PJ CF_TDOTS_1344 CR PC PJ 000 CR Acceptable 8 3 Operation Requirements Functional Execution Command is limited when the projector status is as below However Status Read Command is still effective under following conditions Projector Status Available Functional Execution Command Standby Mode C00 Power ON CF POWER ON Countdown in process C00 Power ON CF POWER ON Terminates Count Down Co...

Page 16: ...hen the power is turned to ALL OFF status the value returns to the original setting It is stored in Suspend mode Response Acceptable 000 CR Unacceptable Error Code CR 8 4 3 CF_COLOR Command Command CF_COLOR_ 1 CR 1 000 063 Directly specify setting value of Color UP Increment setting value of Color by 1 DN Decrement setting value of Color by 1 Details Set user controlled value of Colorl Available o...

Page 17: ...tails Set user controlled value of Gamma Available only in the normal Power ON status The value set by this command will not be stored in the projector s memory Therefore when the power is turned to ALL OFFstatus the value returns to the original setting It is stored in Suspend mode Response Acceptable 000 CR Unacceptable Error Code CR 8 4 7 CF_WBAL Command Command CF_WBAL 1_ 2 CR 1 R RED G GREEN ...

Page 18: ...esponse Acceptable 000 CR Unacceptable Error Code CR 8 4 10 CF_PROGV Command Command CF_PROGV_ 1 CR 1 OFF Set Progressive scan to OFF L1 Set Progressive scan to L1 for movie image L2 Set Progressive scan to L2 for still image FILM Set Progressive scan to Film UP Switch setting forward direction OFF L1 L2 FILM OFF DN Switch setting backward direction OFF FILM L2 L1 OFF Details Set Progressive scan ...

Page 19: ...R 8 4 12 CF_IMAGEADJ Command Command CF_IMAGEADJ_ 1 CR 1 RST Reset adjusted value for the Image STR1 Store current adjusted value to Image 1 STR2 Store current adjusted value to Image 2 STR3 Store current adjusted value to Image 3 STR4 Store current adjusted value to Image 4 Details Reset or Store adjusted value for Image Available only in the normal Power ON status STR1 STR4 corresponds to Image1...

Page 20: ... not be stored in the projector s memory Therefore when the power is turned to ALL OFF status the value returns to the original setting It is stored in Suspend mode Response Acceptable 000 CR Unacceptable 101 CR When input is Video signal No signal 8 5 3 CF_CLPPHASE Command Command CF_CLPPHASE_ 1 CR 1 mmmm nnnn Directly select Clamp phase setting value mmmm shows minimum value the fixed value 0001...

Page 21: ... Position H In this projector the value should be even number and if odd number is specified it adds 1 to make the value even number UP Increment setting value of Display Dots by 2 DN Decrement setting value of Display Dots by 2 Details Set setting value of Display Dots in PC signal Available only in the normal Power ON status The value set by this command will not be stored in the projector s mem...

Page 22: ...and Command CF_ORGMODE_ 1 CR 1 When input signal is PC Analog VGA1 Specify VGA1 VGA2 Specify VGA2 XGA1 Specify XGA1 WXGA3 Specify WXGA3 1080I60 Specify 1080i60 1080I50 Specify 1080i50 1035I Specify 10350i 720p60 Specify 720p60 720p50 Specify 720p50 575p Specify 575p 480p Specify 480p 575I Specify 575i 480I Specify 480i When input signal is not PC Analog error code 101 is returned Details After EXT...

Page 23: ...ts to Mode1 10 This command operates the same way as storing to Mode1 10 in PC Adjust Menu Available only in the normal Power ON status Response Acceptable 000 CR Unacceptable 101 CR When input is Video signal No signal 8 5 11 CF_PCMODEFREE Command Command CF_PCMODEFREE_ 1 CR 1 1 Set Mode1 to Free status 2 Set Mode2 to Free status 3 Set Mode3 to Free status 4 Set Mode4 to Free status 5 Set Mode5 t...

Page 24: ...FF It comes to 101 Response Acceptable 000 CR Unacceptable Error Code CR 8 6 2 CF_SOURCE Command Command CF_SOURCE_ 1 CR 1 Input 1 DIGITAL Select Digital Input ANALOG Select Analog Input SCART Select Scart Input HDCP Select DVI HDCP Input UP Select in Analog Scart DVI HDCP Analog order DN Select in Analog HDCP DVI Scart Analog order Input 2 VIDEO Select Composite Video Input YPBPR Select Y Pb Cb P...

Page 25: ...e only in the normal Power ON status Response Acceptable 000 CR Unacceptable Error Code CR 8 6 5 CF_INPUT 3 Command Command CF_INPUT3_ 1 CR 1 AUTO Select Composite Video Input S Video Input automatically S Video has priority VIDEO Select Composite Video Input S VIDEO Select S Video Input Details Select Input 3 as well as Source specified in 1 Available only in the normal Power ON status Response A...

Page 26: ...35i D 720p Select D 720p D 575p Select D 575p D 480p Select D 480p Input is Y Pb Cb Pr Cr AUTO Select System Auto 1080I Select 1080i 1035I Select 1035i 720P Select 720p 575P Select 575p 480P Select 480p 575I Select 575i 480I Select 480i Input is Video S Video AUTO Select System Auto NTSC Select NTSC NTSC443 Select NTSC4 43 PAL Select PAL SECAM Select SECAM PAL M Select PAL M PAL N Select PAL N Det...

Page 27: ...mand Command CF_DZCENT_ 1 CR 1 CENT Cancel Digital Zoom CENT CENTER Details Cancel Digital Zoom Available only in the normal Power ON status and Input for Computer is selected Response Acceptable 000 CR Unacceptable 101 CR when Input for Video is selected 8 7 3 CF_KEYSTONE Command Command CF_KEYSTONE_ 1 CR 1 UP Correct Keystone distortion to reduce upper part of image FUP Correct Keystone distorti...

Page 28: ... by 1 Details Set Vscale Available only in the normal Power ON status When selected screen mode is not Custom error code 101 CR is returned and it is not executed Error Code 101 CR is returned for no signal Response Acceptable 000 CR Unacceptable Error Code CR 8 7 6 CF_VPOS Command Command CF_VPOS_ 1 CR 1 015 15 014 14 002 2 001 1 000 0 01 1 02 2 14 14 15 15 UP Increment setting value of Vposition...

Page 29: ...returned and it is not executed Error Code 101 CR is returned for no signal Response Acceptable 000 CR Unacceptable Error Code CR 8 7 8 CF_HPOS Command Command CF_HPOS_ 1 CR 1 015 15 014 14 002 2 001 1 000 0 01 1 02 2 14 14 15 15 UP Increment setting value of Hposition by 1 DN Decrement setting value of Hposition by 1 Details Set H Position Available only in the normal Power ON status When selecte...

Page 30: ...red in EEPROM and the setting remains effective after the power is turned to ALL OFF status Response Acceptable 000 CR Unacceptable Error Code CR 8 9 Sound Command 8 9 1 CF_VOLUME Command Command CF_VOLUME_ 1 CR 1 000 063 Directly select Volume setting value UP Current Volume setting value 1 DN Current Volume setting value 1 Details Control level of volume Available only in the normal Power ON sta...

Page 31: ...en after the power is turned to ALL OFF status Response Acceptable 000 CR Unacceptable Error Code CR 8 10 3 CF_LOGO Command Command CF_LOGO_ 1_ 2 CR 1 0000 9999 Directly set Logo PIN code 2 OFF Cancel Logo display DFLT Select Logo of Factory Default USER Select User UP Select functions to choose forward OFF DFLT USER OFF DN Select functions to choose backward OFF USER DFLT OFF Details Set Logo mod...

Page 32: ...ct Code 1 002 Select Code 2 003 Select Code 3 004 Select Code 4 005 Select Code 5 006 Select Code 6 007 Select Code 7 008 Select Code 8 UP Switch forward Code1 Code2 Code3 Code8 Code1 DN Switch backward Code8 Code7 Code6 Code1 Code8 Details Select Code of Remote Control Available only in the normal Power ON status The status set by this command is stored in EEPROM and setting remains effective eve...

Page 33: ...OFF UP Toggle between ON and OFF On Off On DN Toggle between ON and OFF On Off On UP and DN are exactly same operation Details Set Cancel Power ON Start Available only in the normal Power ON status The status set by this command is stored in EEPROM and setting value remains effective even after the power is turned to ALL OFF status Response Acceptable 000 CR Unacceptable Error Code CR 8 10 10 CF_P...

Page 34: ...ommand is stored in EEPROM and setting remains effective even after the power is turned to ALL OFF status Response Acceptable 000 CR Unacceptable Error Code CR 8 10 13 CF_HIGHLAND Command Command CF_HIGHLAND_ 1 CR 1 ON Set Highland mode to ON OFF Set Highland mode to OFF Details Set Cancel Highland mode Available only in the normal Power ON status The status set by this command is stored in EEPROM...

Page 35: ...status PIN code can not be changed Only PIN code lock is canceled When PIN code Lock is enabled PIN code is matched Command is valid Acceptable PIN code is mismatched Command is invalid Error code 102 PIN code is beyond 1 available range Command is invalid Error code When PIN code lock is canceled PIN code is within 1 range Command is valid Acceptable PIN code is out of 1 range Command is invalid ...

Page 36: ...1_ 2 CR 1 SPOTLIGHT Select Spotlight ARROW Select Arrow FINGER Select Finger LASER Select Laser mark 2 MAX Spotlight Large MID Spotlight Medium MIN Spotlight Small Details Select Pointer display Available only in the normal Power ON status Note1 2 is valid only when SPOTLIGHT is specified in 1 When ARROW FINGER LASER is specified in 1 the command should be CF_POINTER_ 1 CR Note2 When SPOTLIGHT is ...

Page 37: ...some projector statuses which indicates the command is impossible to be executed See 8 3 for details Returning the response 000 CR acceptable does not always mean that the status has already changed to Power ON Example When the temperature approaches abnormal status after returning 000 CR to the command CF_POWER ON Therefore to get the projector status requires using Status Read command Details Se...

Page 38: ... projector by Expand Serial Commands PC PJ CR_TDOTS CR PC PJ 000_1344 CR 9 3 Operation Condition Basically it should be always operated 9 4 Image Status Read Command 9 4 1 CR_BRIGHT Command Command CR_BRIGHT CR Details Get user controlled value of Brightness Response Acceptable 000_ 1 CR 1 000 063 Unacceptable CR 9 4 2 CR_CONT Command Command CR_CONT CR Details Get user controlled value of Contras...

Page 39: ...0_ 1 CR 1 000 015 Unacceptable CR 9 4 6 CR_GAMMA Command Command CR_GAMMA CR Details Get user controlled value of Gamma Response Acceptable 000_ 1 CR 1 000 015 Unacceptable CR 9 4 7 CR_WBAL R Command Command CR_WBAL R CR Details Get user controlled Red value of White Balance Response Acceptable 000_ 1 CR 1 000 063 Unacceptable CR 9 4 8 CR_WBAL G Command Command CR_WBAL G CR Details Get user contro...

Page 40: ...OFF L1 Noise Reduction L1 L2 Noise Reduction L2 Unacceptable CR 9 4 12 CR_PROGV Command Command CR_PROGV CR Details Get Progressive scan setting status Response Acceptable 000_ 1 CR 1 OFF Progressive scan OFF L1 Progressive Mode L1 for moving image L2 Progressive Mode L2 for still image FILM Progressive Model FILM Unacceptable CR 9 4 13 CR_IMAGE Command Command CR_IMAGE CR Details Get image settin...

Page 41: ...e CR When command is not available in the given condition such as being selected input CR When unknown command is received 9 5 2 CR_TDOTS Command Command CR_TDOTS CR Details Get value of Total Dots Response Acceptable 000_ 1 CR 1 mmmm nnnn mmmm Display area H Position H nnnn Maximum value less than 140 MHz of Dot Clock Unacceptable Error Code CR When command is not available in the given condition...

Page 42: ...acceptable Error Code CR When command is not available in the given condition such as being selected input CR When unknown command is received 9 5 6 CR_DDOTS Command Command CR_DDOTS CR Details Get value of Display Dots Response Acceptable 000_ 1 CR 1 0100 nnnn nnnn Total Dots Position H Unacceptable Error Code CR When command is not available in the given condition such as being selected input CR...

Page 43: ...20p60 Indicates signal is 720p60 720p50 Indicates signal is 720p50 575p Indicates signal is 575p 480p Indicates signal is 480p 575i Indicates signal is 575i 480i Indicates signal is 480i Note To differentiate between 60Hz and 50Hz in 1080i and 720p 60 or 50 is necessary to add to the parameter in this command When input signal is not PC Analog error code 101 is returned Unacceptable CR 9 5 9 CR_PC...

Page 44: ...lected WXGA3 Indicates WXGA3 is selected 1080I Indicates 1080i is selected 1035I Indicates 10350i is selected 720p Indicates 720p is selected 575p Indicates 575p is selected 480p Indicates 480p is selected 575I Indicates 575i is selected 480I Indicates 480i is selected MODE1 Indicates Mode1 is selected MODE10 Indicates Mode10 is selected EXT11 EXT11 is selected EXT60 EXT60 is selected Error Code 1...

Page 45: ...cceptable 101 CR When input signal is PC Analog PC Digital or PC signals in AV HDCP CR When unknown command is received 9 7 Input Read Command 9 7 1 CR_INPUT Command Command CR_INPUT CR Details Get selected INPUT No Response Acceptable 000_ 1 CR 1 1 4 Unacceptable CR 9 7 2 CR_SOURCE Command Command CR_SOURCE CR Details Get selected source Response Acceptable 000_ 1 CR 1 DIGITAL RGB PC Digital is s...

Page 46: ...le 000_ 1 CR 1 VIDEO in Video mode YPBPR in Y Pb Cb Pr Cr mode ANALOG in RGB mode Unacceptable CR 9 7 5 CR_SRCINP3 Command Command CR_SRCINP3 CR Details Get Source of INPUT3 Response Acceptable 000_ 1 CR 1 AUTO Auto selected Video S Video VIDEO in Video mode S VIDEO in S Video mode Unacceptable CR 9 7 6 CR_SRCINP4 Command Command CR_SRCINP4 CR Details Get Source of INPUT4 Response Acceptable 000_ ...

Page 47: ... D WXGA3 is selected D 1080I indicates D 1080i is selected D 1035I indicates D 1035i is selected D 720P indicates D 720p is selected D 575P indicates D 575p is selected D 480P indicates D 480p is selected D 575I indicates D 575i is selected D 480I indicates D 480i is selected Error Code 101 CR is returned for no signal Input is Y Pb Cb Pr Cr AUTO indicates Auto is selected 1080I indicates 1080i is...

Page 48: ...o is in the list 1080I 1080i is in the list 1035I 1035i is in the list 575I 575i is in the list 480I 480i is in the list When no signal is coming error code 101 is not returned When Input is Video S Video All possible systems in Menu including Auto are returned AUTO Auto is in the list PAL PAL is in the list SECAM SECAM is in the list PAL N PAL N is in the list When no signal is coming error code ...

Page 49: ..._NMSLOT2 CR Details Get terminal information of Input2 Response Acceptable 000_ 1 CR 1 5BNC Unacceptable Error Code CR 9 7 13 CR_NMSLOT3 Command Command CR_NMSLOT3 CR Details Get terminal information of Input3 Response Acceptable 000_ 1 CR 1 VIDEO Unacceptable Error Code CR 9 7 14 CR_NMSLOT4 Command Command CR_NMSLOT4 CR Details Get teminal information of Input4 Response Acceptable 000_ 1 CR 1 NET...

Page 50: ...EO YPBPR Unacceptable Error Code CR 9 7 17 CR_IDSLOT3 Command Command CR_IDSLOT3 CR Details Get ID information of Input3 This command is to determine sources possible to input Response Acceptable 000_ 1 CR 1 52 On borad 3BNC and S VIDEO Available source AUTO VIDEO S VIDEO Unacceptable Error Code CR 9 7 18 CR_IDSLOT4 Command Command CR_IDSLOT4 CR Details Get ID information of Input4 This command is...

Page 51: ... Details Get setting status of Keystone Store Mode Response Acceptable 000_ 1 CR 1 STR Store mode is Store RST Store mode is Reset Unacceptable CR When unknown command is received 9 8 3 CR_VSCALE Command Command CR_VSCALE CR Details Get setting status of V scale Response Acceptable 000_ 1 CR 1 32 032 Unacceptable CR When unknown command is received 9 8 4 CR_VPOS Command Command CR_VPOS CR Details ...

Page 52: ...indicates under lamp replacement time 1 means the number of lamps 1 lamp is used 1 Y N means if it is time to replace lamp or not Example 1Y 1 lamp is used and it is over lamp replacement time Unacceptable CR 9 9 2 CR_LAMPH Command Command CR_LAMPH CR Details Get Lamp running time in hours return actual lamp running time Response Acceptable 000_ 1 CR 1 00000 99999 Unacceptable Error Code CR 9 9 3 ...

Page 53: ...CO2 Lamp Mode is Eco2 Unacceptable CR 9 9 5 CR_LAMPSTS Command Command CR_LAMPSTS CR Details Get Lamp status Response Acceptable 000_ 1 CR 1 1I Lamp is ON 1O Lamp is OFF 1X Lamp Failure Unacceptable Error Code CR 9 9 6 CR_PROJH Command Command CR_PROJH CR Details Get total running time of Projector in hours Response Acceptable 000_ 1 CR 1 0000000 0099999 Unacceptable CR 9 9 7 CR_HMLAMP Command Com...

Page 54: ...d Command 9 11 1 CR_BACKGND Command Command CR_BACKGND CR Details Get setting status of Screen for no signal Response Acceptable 000_ 1 CR 1 BLUE Blue Back is selected USER User is selected BLACK Black Back is selected Unacceptable Error Code CR 9 11 2 CR_DISP Command Command CR_DISP CR Details Get setting status of Display Response Acceptable 000_ 1 CR 1 ON Display is ON CNTDWNOFF Count down is O...

Page 55: ...n Response Acceptable 000_ 1 CR 1 ON Rear projection is enabled OFF Rear projection is disabled Unacceptable Error Code CR 9 11 7 CR_RCODE Command Command CR_RCODE CR Details Get selected Remote Control Code Response Acceptable 000_ 1 CR 1 001 Code 1 is selected 002 Code 2 is selected 003 Code 3 is seleccted 004 Code 4 is selected 005 Code 5 is selected 006 Code 6 is selected 007 Code 7 is selecte...

Page 56: ...lian is selected ESP Spanish is selected POR Portuguese is selected NED Dutch is selected SVE Swedish is selected JPN Japanese is selected CHI Chinese is selected KOR Korean is selected RUS Russian is selected Unacceptable CR 9 11 11 CR_ON STA Command Command CR_ON STA CR Details Get setting status of Power ON Start Response Acceptable 000_ 1 CR 1 ON Power ON Start is ON OFF Power ON Start is OFF ...

Page 57: ...t selected Highland mode Response Acceptable 000_ 1 CR 1 ON Highland mode is ON OFF Highland mode is OFF Unacceptable CR 9 11 16 CR_SLANT Command Command CR_SLANT CR Details Get setting status of Slant setting Response Acceptable 000_ 1 CR 1 OFF Projector is installed without slant L1 Projector is slanted at degree angle L2 Projector is slanted at degree angle Unacceptable CR 9 11 17 CR_KEYDIS Com...

Page 58: ... ON2 on the menu but PIN code Lock mode is canceled because PJ PIN code is entered Unacceptable Error Code CR 9 11 20 CR_PJLOCKMENU Command Command CR_PJLOCKMENU CR Details Get ON OFF setting status of PIN code lock on menu Response Acceptable 000_ 1 CR 1 ON1 PIN code lock ON 1 is set on the menu ON2 PIN code lock ON 2 is set on the menu OFF PIN code lock OFF is set on the menu Unacceptable Error ...

Page 59: ...er cleaning replacement time Response Acceptable 000_ 1 CR 1 1Y Filter Exchange time is over value of Filter Message 1N Filter Exchange time is not over value of Filter Message Unacceptable Error Code CR 9 11 25 CR_FILTIMER Command Command CR_FILTIMER CR Details Get Filter used time Response Acceptable 000_ 1 CR 1 100 100 hours 200 200 hours 300 300 hours OFF Warning OSD is not displayed Unaccepta...

Page 60: ...ing Down in process 04 Power Save 21 Cooling Down in process after turened Off due to lamp failure 81 Standby after Cooling Down due to lamp failure Unacceptable Error Code CR 9 12 2 CR_SIGNAL Command Command CR_SIGNAL CR Details Get status whether there is any signal or not Response Acceptable 000_ 1 CR 1 ON There is signal OFF There is no signal Unacceptable CR 9 12 3 CR_VMUTE Command Command CR...

Page 61: ...es sensor 1 data then one space and sensor 2 data Last character in each data indicates the sensor s status F Exceeding critical temp abnormal temp W Approaching critical temp Warning temp S Sensor temp is safe Safe temp N Sensor detects no critical temp E Unable to return the temp data The example 1 shows that sensor 1 indicates 31 5 degrees and the temperature is abnormal sensor 2 indicates 35 2...

Page 62: ...emp is safe Safe temp N Sensor detects no critical temp E Unable to return the temp data With more than one temperature sensors installed projector returns responses in a row e g _31 5F _ _35 2S _ _38 0W CR The first data indicates sensor 1 data then one space and sensor 2 data The example 1 shows that sensor 1 indicates 31 5 degrees and the temperature is abnormal sensor 2 indicates 35 2 degrees ...