background image

1

10 GALLON 

Box Extractor 

SC6085 Series

Part No. SC6085 Rev 2 (3/14)

Owner’s Guide

PLEASE RETAIN

We suggest you record the model, type, and serial numbers 

below.  They are located on the silver rating plate on your 

unit.  For prompt and complete service information, always 

refer to these numbers when inquiring about service.

 

Model & Type____________________________

Serial No._______________________________

It is also important to keep your receipt as proof of date of 

purchase.

©2014 Electrolux Home Care Products Ltd.

IMPORTANT

Do not return this product to the store.  

Call 1-800-800-8975* 

Monday - Friday 8:00 AM to 7:30 PM 

and Saturday 10 AM to 6:30 PM 

Central time or visit our web site, 

www.sanitairevac.com for any of the 

following:

• 

assembly problems

• 

replacement of broken or missing 

items

• 

to review repair parts list

• 

to order replacement parts and   

accessories

• 

to locate the nearest sanitaire 

warranty station

*En Mexico llame al 5670-6169

www.sanitairevac.com

Sanitaire

®

X1008

Summary of Contents for SC6085 Series

Page 1: ..._______________ It is also important to keep your receipt as proof of date of purchase 2014 Electrolux Home Care Products Ltd IMPORTANT Do not return this product to the store Call 1 800 800 8975 Monday Friday 8 00 AM to 7 30 PM and Saturday 10 AM to 6 30 PM Central time or visit our web site www sanitairevac com for any of the following assembly problems replacement of broken or missing items to ...

Page 2: ...hts which vary from state to state There are no warranties express or implied written or verbal which extend beyond the description found in this manual GROUNDING INSTRUCTIONS This appliance must be grounded If it should malfunction or breakdown grounding provides a path of least resistance for electric current to reduce the risk of electric shock This appliance is equipped with a cord having an e...

Page 3: ...rking as it should has been dropped damaged left outdoors or dropped into water return it to a service center Do not pull or carry by the cord use the cord as a handle close a door on a cord or pull cord around sharp edges or corners Do not run the unit over the cord Do not handle the plug or the unit with wet hands To reduce the risk of health hazards from vapors or dusts do not vacuum toxic mate...

Page 4: ...nsequently it is important to protect your interest by carefully complying with the following instructions Please inspect your cartons for any damage including concealed damage that might have occurred during shipment Any damage is the responsibility of the freight carrier and should be reported to the freight carrier immediately It is your responsibility to issue a claim and to receive compensati...

Page 5: ...ert it into the solution tank Turn the vacuum switch to on position and transfer solution to recovery tank Fig 8 8 Empty the recovery tank by using the drain hose on the front of the machine Do not use the same pail to fill the solution tank as this can result in putting dirt and grit into the solution line that can plug filters orifices and degrade system do not reuse solution Fig 7 Fig 3 4 Assem...

Page 6: ...r and alkaline deposits and aid in keeping orifices clean 4 Do not allow fluid either in solution or waste tank to sit overnight The unit should be emp tied and cleaned daily 5 Clean the strainer in the solution tank the filters on the vacuum stack in vacuum tank and all lint filters in the inlet or vacuum tanks daily Fig 10 6 When the unit is not in use leave the vacuum tank lid open Fig 11 7 At ...

Page 7: ... not store in freezing temperature 5 A small amount of windshield washer fluid may be left in the pump and internal solution line for protection against freezing TROUBLESHOOTING NO ELECTRICAL POWER CAUSE 1 Defective power cord 2 Circuit breaker off or blown fuse SOLUTION 1 Replace 2 Turn circuit breaker on or replace fuse Unplug any equipment using the same circuit INTERMITTENT POWER TO MOTORS SOL...

Page 8: ...EVEN SPRAY FROM JETS NO SPRAY FROM JETS CAUSE 1 Clogged or faulty solution control valve 2 Clogged or faulty quick disconnect 3 Punctured pump diaphragm 4 Clogged jets SOLUTION 1 Check valve for debris 2 Depress plunger on solution hose quick disconnect on against inside wall of solution tank housing If solution is flowing at this point the system is O K If no solution flows check the quick discon...

Page 9: ...SE 1 Defective pump SOLUTION 1 Replace pressure control switch LOW PUMP PRESSURE CAUSE 1 Clogged strained in solution tank 2 Punctured pump diaphram 3 Defective rectifier or motor SOLUTION 1 Clean and replace 2 Replace 3 Replace ...

Reviews: