Summary of Contents for DAS-10

Page 1: ...ed 28 october 2014 Z10 3 edition 1 Code 002 205 ENGLISH Sams elektronik d o o 48 Zivka Davidovica st 11050 Belgrade Serbia Tel Fax 381 11 3806 253 381 11 2402 212 sams sams rs www sams rs USER MANUAL FOR USE AND MAINTENANCE Read the instructions before using the device Keep this manual for periodic usage ...

Page 2: ...er servicer has not completed repair or replacement within a reasonable time or if the manufacturer servicer did not perform repair or replacement without significant inconvenience to the consumer 5 The consumer may not terminate the contract if the lack of conformity of the product is negligible 6 The product will function properly when used in accordance with the user manual 7 Period of servicin...

Page 3: ...h voltage In poor conditions the user may be exposed to shock The symbol exclamation mark in a triangle is to alert the user to comply by the terms of use in user s manual which is supplied with the device SAFETY WARNINGS ELECTRICAL SHOCK HAZARD DO N OT O PEN CAUTION RIZIK OD S TRUJNOG UDARA NE O TVARATI DOK JE P OD N APONOM UPOZORENJE CLASS I DEVICE Grounding is connected to the chassis of the de...

Page 4: ...e is equipped with a protective fuse in the power outlet Do not bypass fuse 12 Do not replace the fuse Replacement can be made by a person authorized by the manufacturer 13 Do not bend the power cord so that it can be damaged 14 Connect connectors as in the enclosed instructions Deviations from the allowed values predicted for the inputs and outputs of the device can cause severe damage and warran...

Page 5: ...CABLE CONNECTION BETWEEN SWITCHER AND REMOTE 8 REMOTE CONTROL NSCU 10 9 REMOTE CONTROL SCU 10 10 IMPEDANCE ADJUSTMENT 11 SETTING THE DEVICE GROUNDING 12 CONFIGURATION AND CONNECTION GRAPHIC EXAMPLE 12 NETWORK SETUP 13 NETWORK ACCESS AND DEVICE CONTROL 13 PROBLEMS AND SOLUTIONS IN A NETWORK ENVIRONMENT 15 SOFTWARE SUPPORT 17 NOTES 18 Page Description TABLE OF CONTENTS ...

Page 6: ...device must be stored in a room without moisture The system maintains only person authorized by Sams elektronik doo Any voluntarily opening device upgrading or servicing is strictly prohibited and is subject to warranty void and the possibility of injury Places for fastening PROCEDURES FOR SAFE USE OF THE DEVICE 1 Remove the protective wrap from the chassis For devices that are AC 230V 50Hz powere...

Page 7: ...ECHNICAL SPECIFICATIONS GENERAL INFORMATION Code 002 205 Weight 1 5 Kg Type 1RU rack frame Dimensions 1RU x 19 x 100mm Required remote control SCU 10 Delivery includes device power corde user manual AES3 110Ω INPUT Connector 3 pin terminal switch Impedance 110Ω Max level 7V p p Min level 0 2V p p AES3 110Ω OUTPUT Connector 3 pin terminal switch Impedance 110Ω Nominal level 3 1V p p 10 Rising time ...

Page 8: ... 2 3 4 5 6 7 8 9 10 PAN LOCK Remote panel 10x1 with GPI AES EBU Digital audio switcher 10x1 110Ω 75Ω DAS 10 www sams rs REMOTE WORD CLOCK STATUS GREEN remote on word clock on RED remote off word clock on GREEN BLINK remote on word clock off RED BLINK remote off word clock off Connect the power cord The device works only on AC 230 V 50 Hz external reference TCP IP DAS 10 rear side DAS 10 front side...

Page 9: ...made in this way are detected by remote control GPI Ethernet GPI connector GPI 1 GPI 1 2 GPI 2 3 GPI 3 4 GPI 4 5 GPI 5 6 GPI 6 7 GPI 7 8 GPI 8 9 GPI 9 10 GPI 10 11 25 GND GPI PINOUT www sams rs SN MODEL REMOTE NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED PERSONNEL NETWORK TCP IP MAC ADDRESS To find this device through network use Sams NETFINDER software Download software only from...

Page 10: ...DAS Switchers elektronik Sams elektronik d o o sams sams rs www sams rs 10 REMOTE CONTROL SCU 10 The connection to the switcher ...

Page 11: ...ange the input impedance to 75Ω set jumper Each input can be independently configured Jumpers are marked with the name IJMP1 Place the jumper at the input Place the jumper on the output 110Ω 75Ω The factory setting 110Ω 75Ω 75Ω 110Ω JMP1 JMP1 110R 110R 75R 75R The output is factory set to 110Ω To change to 75Ω switch jumper as shown below Wiring inputs Wiring output G G G G ...

Page 12: ...ams rs www sams rs 12 CONFIGURATION AND CONNECTION GRAPHIC EXAMPLE SETTING THE DEVICE GROUNDING PC Remote control AES EBU switcher SDI switcher In systems where it is required GROUND LIFT this option is enabled by setting jumper OJ1 The factory is not set ...

Page 13: ...e desired device and press the Web Browser located on the left side of the software Browser will display the configuration options NOTE The device will be found from across the network only if the device was connected to a network cable before turning on If the program NETFINDER does not find the device on the network try the following Connect the inserter directly to the computer The computer set...

Page 14: ... rs 14 After a few seconds the page will open Web browser WORD CLOCK status f it is green everything is OK If it is red check cable or source of reference Each number represents the buttons of incoming signal Pressing the button connects the selected input to the output ...

Page 15: ...NDER is not able to locate the device in the network try the following 1 Right click on Local Area Connection 2 Select option Change Windows Firewall settings 3 When a window Windows Firewall opens select tab Exceptions 4 Click on button Add program PROBLEMS AND SOLUTIONS IN A NETWORK ENVIRONMENT ...

Page 16: ...255 0 default gateway and DNS leave blank 5 Turn off all kinds of firewalls completely 6 Install Tiny DHCP server 7 In Tray icon will appear in the form of two shaking hands 8 Click on that icon 9 In the opened window click the button Add new 10 Enter the MAC address of the device MAC address is entered without dashes dots and spaces and press OK 11 If the field is not marked with the MAC address ...

Page 17: ...10 ref send feedback about status of word clock Enter in form ref Feedback is 0 no reference 1 reference present EXAMPLE http ip_adresa get_data src 0 This means first input selected NOTE If you use a web browser for programming we recommend that it be Mozilla Firefox with desabled options to cache the page 17 If the tray icon of DHCP server has not changed its color when you turn the device turn ...

Page 18: ...DAS Switchers elektronik Sams elektronik d o o sams sams rs www sams rs 18 NOTES ...