background image

FStart

 

Pressure / Suction

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

135756312 Gun FStart P Compliant HVLP-12-XLva 

135756315 Gun FStart P Compliant HVLP-15-XLva 

135756318 Gun FStart P Compliant HVLP-18-XLva 

135756412 Gun FStart P CONV-12-XLva 

135756415 Gun FStart P CONV-15-XLva 

135756418 Gun FStart P CONV-18-XLva 

135756515 Gun FStart S CONV-15-Mva 

135756518

 

Gun FStart S CONV-18-Mva

 

135756712 Gun FStart P Compliant LVLP-12-XLva 

135756713 Gun FStart P Compliant LVLP-13-XLva 

135756715 Gun FStart P Compliant LVLP-15-XLva 

135756718 Gun FStart P Compliant LVLP-18-XLva

 

 II 2G Ex h IIB T6 Gb X 

 

Translation from the original manual - Index C 

582120110-US 

 

 

SAMES KREMLIN SAS 

 

13 Chemin de Malacher 

38240 Meylan 

 

Tél.: 33 (0)4 76 41 60 60 

www.sames-kremlin.com 

 

Summary of Contents for FStart P HVLP-12-XLva

Page 1: ...art P CONV 18 XLva 135756515 Gun FStart S CONV 15 Mva 135756518 Gun FStart S CONV 18 Mva 135756712 Gun FStart P Compliant LVLP 12 XLva 135756713 Gun FStart P Compliant LVLP 13 XLva 135756715 Gun FStar...

Page 2: ...sembly Disassembly 15 13 Assembly errors 16 14 Troubleshooting 16 15 FStart Pressure Suction commercial references 18 15 1 Available projectors references P Ns 20 15 2 Available accessory references P...

Page 3: ...r balance at all times to better control the equipment in the event of an unexpected event Make sure that the workstation is neat and clean Scattered or piled up parts and tools are a source of an acc...

Page 4: ...ause a risk of fire poisoning or irritation Toxicity Depending on the fluid used toxic and or flammable vapors may form There is a danger of intoxication and burning due to the concentration of these...

Page 5: ...ire brushes files or pliers for disassembly Before cleaning or disassembling any component of the equipment it is imperative to stop the pump by cutting off the compressed air supply to decompress the...

Page 6: ...ification of equipment made by the user and not authorized by SAMES KREMLIN will result in loss of certification Environment Environmental risks must be controlled as follows Respect an average temper...

Page 7: ...varnishes lacquers shades polyurethanes 4 2 Description of the ATEX UKCA marking Each device is marked with the name of the manufacturer the reference of the device and important information for the u...

Page 8: ...device IIB Reference gas for equipment qualification T6 Temperature class Maximum surface temperature 85 C 185 F Gb Gb Equipment protection level Gas zone 1 X X Special conditions that apply for a sa...

Page 9: ...ork 6 bar 87 psi Maximum fluid supply pressure 6 bar 87 psi Product supply M 3 8 NPS Air flow rate 22 1m3 h 19 4m3 h 23m3 h 21 3m3 h Air pressure at the gun handle 3 bar 43 5 psi 2 2 bar 31 9 psi 2 5...

Page 10: ...odel Air and fluid supply Air Male 1 4 NPS Air hose anti static quality HVLP LVLP minimum 8 mm ID for a 7 5 m 24 6 ft length CONV minimum 7 mm ID for a 7 5 m 24 6 ft length Fluid Male 3 8 NPS For pres...

Page 11: ...Pump 2 Airspray gun 3 Fluid hose 4 Antistatic air hose 5 Air regulator The 1 m 39 37 distance indicated in the diagram is given for information purposes only and hold harmless to SAMES KREMLIN The us...

Page 12: ...id fitting to the pump Tighten the fittings firmly Note In some particulars cases if the air hose 4 is not conductive the fluid hose 3 must be conductive One of the 2 gun hoses air or fluid must be co...

Page 13: ...e Pull the trigger and check that the air is circulating normally 9 Adjustments This professional spray gun features 3 controls Spraying fineness Air is fed by the central air The air is adjusted by m...

Page 14: ...n perpendicular to the surface to be painted Avoid working with the wrist Do not forget that crossed sweeps cannot correct irregularities Spraying from a stationary gun will not give you even coverage...

Page 15: ...m before assembling refer to seal and servicing kits Note Frequencies are given as an estimate They must be adapted by the maintenance service of the user for every installation depending on the fluid...

Page 16: ...eedle almost closed the spray pattern is not even in all directions Fragmented pattern The fan air pressure is too high at the holes in the air cap horns turn the fan air control clockwise to reduce t...

Page 17: ...seeping from the air holes of the aircap Defective nozzle seal Replace it Nozzle loose Tighten it Fluid leak at the packing Packing is worn Tighten up the packing holder without blocking the needle If...

Page 18: ...rialAircap material P Pressure S Suction HVLP High volume Low pressure CONV Conventional LVLP Low volume Low pressure Nozzle size 12 1 2 mm 13 1 3 mm 15 1 5 mm 18 1 8 mm XLva or Mva Maximum fan width...

Page 19: ...Gun FStart P CONV 12 XLva 135756415 Gun FStart P CONV 15 XLva 135756418 Gun FStart P CONV 18 XLva 135756712 Gun FStart P Compliant LVLP 12 XLva 135756713 Gun FStart P Compliant LVLP 13 XLva 135756715...

Page 20: ...31756312 Nozzle Needle FStart LVLP 12 131756313 Nozzle Needle FStart LVLP 13 131756315 Nozzle Needle FStart LVLP 15 131756318 Nozzle Needle FStart LVLP 18 132756310 Aircap FStart P HVLP 12 18 XLva 132...

Page 21: ...s and 10 cover seals for suction cup 15 3 Available packages references P Ns Packages 152756420 Pack Airspray Lucky 2 FStart P HVLP Tank 2L 152756550 Pack Airspray Lucky 2 FStart P CONV Tank 2L 152756...

Page 22: ...22 16 Maintenance kit 129 756 902 16 1 Visual diagrams B B B A C C...

Page 23: ...packing A 5 Packing gasket 2 6 Needle packing screw 1 7 Pattern adjustment valve set 1 129 756 905 Trigger set air adjusters B 21 E ring 1 22 Trigger 1 23 Trigger stud 1 25 Air adjustment valve set 1...

Page 24: ...24 Accessory required for assembly disassembly Designation Visual Wrench delivered with the FStart Pressure Suction guns 17 Dimensions FStart Pressure Suction Pressure Suction...

Page 25: ...artial replacement of the defective component SAMES KREMLIN only bears the cost of the parts needed to replace the defective material No guarantee will be granted by SAMES KREMLIN for the following Fo...

Page 26: ...glementeringen zeker te stellen dat de gebruikers v an dit apparaat zijn opgeleid de v eiligheidsregels perf ect hebben begrepen en dat zij die ook toepassen F r en s ker anv ndning av utrustningen an...

Page 27: ...ce document Declaration s of conf ormity at the back of this document Konf ormit tserkl rung en auf der R ckseite dieser Unterlage Declaraci n es de conf ormidad en el rev erso de este documento Dichi...

Page 28: ...yhlasuje e zariadenie uveden ni ie Kijelenti hogy a megjel lt anyag a tov bbiakban Declar c echipamentul precizat mai jos D i y tuy n b r ng thi t b A a da belirtilen ekipman n PISTOLETS MANUELS DE PU...

Page 29: ...clara o de conformidade emitida sob a exclusiva responsabilidade do fabricante Deze conformiteitsverklaring w ordt verstrekt onder volledige verantw oordelijkheid van de fabrikant Denna f rs kran om v...

Page 30: ...tov bbiakban Declar c echipamentul precizat mai jos D i y tuy n b r ng thi t b A a da belirtilen ekipman n PISTOLETS MANUELS DE PULVERISATION PNEUMATIQUES AIRSPRAY MANUAL SPRAYING GUNS LUFTZERST UBEND...

Page 31: ...del fabbricante A presente declara o de conformidade emitida sob a exclusiva responsabilidade do fabricante Deze conformiteitsverklaring w ordt verstrekt onder volledige verantw oordelijkheid van de f...

Reviews: