background image

SMC-GM-CWSG-M5-2019.11v1_2019-11-24

Connected Wireless System Guide

Module 5 – Connected Fan Coil Controls

Summary of Contents for ST100ZB

Page 1: ...SMC GM CWSG M5 2019 11v1_2019 11 24 Connected Wireless System Guide Module 5 Connected Fan Coil Controls...

Page 2: ...l Controller Installation 5 3 Optional External Antenna Sold Separately 5 5 ST103ZB Wireless Fan Coil Remote Installation 5 6 6 Pairing Instructions Fan Coil Controls Pairing Instructions 6 1 Joining...

Page 3: ...This page intentionally left blank...

Page 4: ...ols Below is a description of several icons used to direct the reader s attention Special Attention Boxes This manual uses special attention icons to alert the reader of important safety concerns info...

Page 5: ...internet connection Module 4 Wireless HVAC Thermostats Introduction Section 1 By connecting the SG888ZB Gateway to your home network the system is connected to the worldwide web Monitor or adjust you...

Page 6: ...Fan Coil Controls Section 2 Table 2 1 Keypad Functions MODE Heat Cool Auto Off selection Increase Value Fan On Auto Low Speed Medium Speed or High Speed Decrease Value Enter Exit Settings mode SELECT...

Page 7: ...Test Mode Special Code 22 Keys Locked Mode Battery Low ST103 Wireless Remote Only Change Filter Timer expired Accessory Output On Humidifier Dehumidifier ERV or HRV Internal External Temperature Sens...

Page 8: ...r optional for existing thermostat terminals Wiring Labels Mounting Screws Thermostat with Wiring Mount Installation Quick Start Guide English French Tools Required Module 5 Connected Fan Coil Control...

Page 9: ...Fan Signal Low Speed Fan Signal Low Speed Gm Orange Fan Signal Medium Speed Fan Signal Medium Speed Gh Yellow Fan Signal High Speed Fan Signal High Speed Ac Accessory Contact Accessory Contact Ac Acc...

Page 10: ...Power Fan Coil Thermostat Section 3 Thermostat Installation Table 3 2 Wiring Configuration Checklist Configuration L N WY YA Gl Gm Gh Ac Ac Tp Tx Ts Tc 2 Pipe Heat Only W o o o o o o 2 Pipe Cool Only...

Page 11: ...le 5 Connected Fan Coil Controls ST100ZB Line Power Fan Coil Thermostat Section 3 ST100ZB 2 Pipe Application ST100ZB 2 Pipe Auxiliary Heat Application ST100ZB 4 Pipe Application ST100ZB Internal Block...

Page 12: ...h Thermostat to the Wiring Mount by aligning the connector pins Make sure the connector pins are not bent and that the Thermostat is fully seated on the wiring mount Remove any unused pre wired leads...

Page 13: ...ional Power Drill optional Wiring Labels Mounting Screws Thermostat with Wiring Mount Installation Quick Start Guide English French Tools Required Be sure that all parts listed are included and availa...

Page 14: ...g Cooling Valve Actuator YA Cooling Valve Actuator Auxiliary Heat Gl Fan Signal Low Speed Fan Signal Low Speed Gm Fan Signal Medium Speed Fan Signal Medium Speed Gh Fan Signal High Speed Fan Signal Hi...

Page 15: ...provided on the following page Thermostat Installation Table 3 2 Wiring Configuration Checklist Configuration R C WY YA Gl Gm Gh Ac Ac Tp Tx Ts Tc 2 Pipe Heat Only W o o o o o o 2 Pipe Cool Only Y o...

Page 16: ...e 5 Connected Fan Coil Controls ST101ZB Low Voltage Fan Coil Thermostat Section 4 ST101ZB 2 Pipe Application ST101ZB 2 Pipe Auxiliary Heat Application ST101ZB Internal Block Diagram ST101ZB 4 Pipe App...

Page 17: ...Coil Thermostat Section 4 Step 3 Attach Thermostat to the Wiring Mount by aligning the connector pins Make sure the connector pins are not bent and that the Thermostat is fully seated on the wiring m...

Page 18: ...ZB Wireless Fan Coil Controller with Wiring Mount Installation Quick Start Guide English French Tools Required Be sure that all parts listed are included and available before starting installation Sma...

Page 19: ...ling Valve Actuator YA Cooling Valve Actuator Auxiliary Heat Gl Fan Signal Low Speed Fan Signal Low Speed Gm Fan Signal Medium Speed Fan Signal Medium Speed Gh Fan Signal High Speed Fan Signal High Sp...

Page 20: ...ns are provided on the following page SC102ZB Fan Coil Controller Installation Table 5 2 Wiring Configuration Checklist Configuration R C WY YA Gl Gm Gh Ac Ac Tp Tx Ts Tc 2 Pipe Heat Only W o o o o o...

Page 21: ...an Coil Controls SC102ZB Wireless Fan Coil Controller ST103ZB Wireless Fan Coil Remote Section 5 SC102ZB 2 Pipe Application SC102ZB 2 Pipe Auxiliary Heat Application SC102ZB Internal Block Diagram SC1...

Page 22: ...e attach the antenna as follows before attaching the controller to the wiring mount Step 1 Remove the antenna connector cover located on the bottom of the SC102ZB Fan Coil Controller Avoid locations t...

Page 23: ...e Section 6 Pairing Instructions for details For desk top operation the ST103ZB can be moved to a different location at any time Wall Mounting Desk or Cabinet Top Mounting Step 1 Remove the Wall Mount...

Page 24: ...an Coil Thermostat Joining the SG888ZB Gateway Network When the Fan Coil Thermostat Controller or Remote is first powered all segements will be briefly displayed The boot sequence described previously...

Page 25: ...as displayed Step 3 Choose the check box that corresponds to the device to connect Note that multiple devices can be connected at the same time Step 4 Enter a unique descriptive name to identify each...

Page 26: ...C102ZB tile to make it flip on the screen Step 9 Click 1 Available remotes Step 10 Choose Link next to the desired remote Step 7 Press Finish to complete connection The devices will appear on the SALU...

Page 27: ...iguring Fan Coil Controls with SALUS Smart Home Application To change configuration settings choose the setup icon from the SC102ZB menu For more configuration settings enter 49 for the device passwor...

Page 28: ...T and EXT Press SELECT to choose the flashing value and move to the next setting If INT is chosen INT will not be displayed on the home screen Setback Use this setting to choose a setback temperature...

Page 29: ...andalone or local mode only Year To set the year use the or keys to change the flashing year value Press SELECT to choose the value displayed and move to the next setting Note This setting is availabl...

Page 30: ...ECT to accept the set point and move on to the next interval Set points for remaining time intervals Set the start time and heating and or cooling temperature for the remaining interval for a total of...

Page 31: ...con will flash The internet will be visible if a connection is established Test Mode Press SELECT to initiate Test Mode Parameter Setup Mode Press SELECT to initiate Parameter Setup Mode Use the and k...

Page 32: ...ction 3 If the thermostat is paired with a network UnPAir is displayed with flashing Press the or key to change the flashing letter to Press SELECT to remove the thermo stat from the network Factory R...

Page 33: ...B ST103ZB Network State None Thermostat is not part of a network SC102ZB acts as a Zigbee coordinator Thermostat is part of a network disconnected from SG888ZB Thermostat is connected to SG888ZB Unive...

Page 34: ...ermostat is following the schedule Permanent Hold Once in Temporary Hold press SELECT to toggle between temporary and permanent override When in permanent override the LCD display on the Fan Coil Ther...

Page 35: ...he TPI Span algorithm selected in Parameter 23 See Appendix A High Gh Medium Gm Low Gl ON Fan output is constant at the selected speed The fan will remain running when a thermostat call is not present...

Page 36: ...ain the specified value The following table shows the function of the accessory output depending on which accessory is selected under parameter 22 See Appendix A Parameter P22 Setting Operation of Ac1...

Page 37: ...ctive Inactive 1 Normally Closed Open Setback Off Close Inactive Inactive 2 Normally Open Open Inactive Inactive Close Setback Off A contact state change detected between the two terminals will initia...

Page 38: ...ircuit If sensor is set to Internal default replace thermostat or use external sensor Error 04 Room temperature sensor circuit is open If sensor is set to Internal Default replace thermostat or use ex...

Page 39: ...0 P04 Max heating setpoint 41 to 92 F 5 to 33 5 C 92 F 33 5 C Not displayed if P02 1 P05 P04 P04 P06 1 5 C P05 Min heating setpoint 41 to 92 F 5 to 33 5 C 41 F 5 C Not displayed if P02 1 P05 P04 P05 P...

Page 40: ...o 68 F increment 1 F 10 to 20 C increment 0 5 C 15 C 59 F Display only if P16 1 2 P18 Setback cooling setpoint 23 to 32 C increment 0 5 C 73 to 90 F increment 1 F 86 F 30 C Display only if P16 1 2 P19...

Page 41: ...ote In Auto mode keys will lock after 5 minutes of keypad inactivity 1 Auto lock keys after 5 minutes 2 Unlock P37 Enable Disable User Unlock in Simple mode and Local mode 0 user can unlock by and v 0...

Reviews: