Thank you for selecting Salsbury 90000 Series Plastic Lockers.  We are confident that the quality and construction of the lockers will prove to be a 
good investment.  These instructions are intended to assist you in the assembly of the lockers.  Individual job conditions will dictate whether the 
lockers must be anchored to the wall, the floor, or both.  

Please read the entire assembly instruction document before beginning assembly. 

 

Step 1.

  Insert the back panel  tabs into the pockets along  the rear 

edge of the side panel.  Tap with soft mallet to engage two (2) latch 
points.

 

 

Step 2

.  Press another side panel onto the tabs on the other side of 

the back panel.  Tap to engage as above. 

 

 

Step  3.   

Join  and  press  down  the  sides-and-back-panel  assembly 

from step 2 above into the base panel as shown below.  The base 

panel is  the thicker of  the six (6) horizontal panels provided.   Then 
thread  four  (4)  leveling  feet  provided  into  the  bottom  of  the  base 
panel. 

 

 
 

Step 4.

  Install a thinner top horizontal panel on top of the unit. 

 

 

Step  5.

    Assemble  four  (4)  identical  units  the  same  as  Steps  1 

through 4, except installing the thinner top panel on each instead of 
the thicker base panel.  These units will not have leveling feet. 

 

 

Step 6.

   If no optional sloping hood is ordered, install  the three (3) 

filler strips into the recesses in the top panel of one (1) of the upper 
units.  This will be the uppermost unit after the units are stacked. 

 

 

SIDE 

PANEL 

BACK 

PANEL 

OTHER 

SIDE PANEL 

BASE PANEL 

(THICKER) 

SIDE 

PANELS 

TOP 

PANEL 

BACK 

PANEL 

LOWER 

(FIRST) 

UNIT 

 

UPPER 

(2

nd

, 3

rd

, 4

th

, 5

th

UNITS 

 

LEVELING FEET 

(NOT SHOWN) 

TOP PANEL 

(THINNER) 

LOWER 

(FIRST) 

UNIT 

 

FILLER 

STRIPS 

FILLER STRIPS 

INSTALLED 