background image

VKS

EN      MOUNTING AND INSTALLATION INSTRUCTION

Summary of Contents for VKS 400-200-4 L1

Page 1: ...VKS EN MOUNTING AND INSTALLATION INSTRUCTION ...

Page 2: ...d regular conditions of transportation Upon unpacking check the unit for any damages caused during transportation It is forbidden to install damaged units The package is only a protection means At unloading and storing the units use suitable lifting equipment to avoid damages and injuries Do not lift units by holding on power supply ca bles connection boxes air intake or discharge flanges Avoid hi...

Page 3: ...ngth is se lected Do not connect the elbows in vicinity of the connection flanges of the unit The minimum distance of the straight air duct between the unit and the first branch of the air duct in the suction air duct must be 1xD in air exhaust duct 3xD where D is diameter of the air duct For rectangular air ducts where B width of the air duct and H height of the air duct When connecting air ducts...

Page 4: ...motor If fan motor speed controller is used ensure that it provides safe operation of the motor Ensure the minimum fan speed at which the back draft dampers open if installed WIRING DIAGRAM 1 1 230V U1 U2 Z1 Z2 TK brown blue black orange white 2 Δ 3 230V Y 3 400V U1 U2 V1 V2 W1 W2 TK brown red blue grey black orange white START UP Operation start up of the unit shall be performed only by trained a...

Page 5: ...l down Follow the above safety requirements The unit switches off Check if voltage and current of the mains correspond to the requirements indicated on the product label Check for power availability to the unit Upon elimination of power supply faults switch on the unit again The fan motor stops because of overheating and external protection is activated Allow the motor to cool down for 15 20 minut...

Page 6: ...t temperature Co 20 20 20 20 20 20 motor protection class IP54 IP54 IP54 IP54 IP54 IP54 wiring diagram 1 2 1 2 1 2 VKS 600 300 4 L1 600 300 4 L3 600 350 4 L1 600 350 4 L3 700 400 4 L3 800 500 4 L3 800 500 6 L3 1000 500 4 L3 phase voltage 50 Hz VAC 1 230 3 400 1 230 3 400 3 400 3 400 3 400 3 400 power kW 1 15 1 50 2 4 2 50 3 70 5 0 2 70 5 0 current A 5 1 2 60 11 0 4 10 6 00 8 1 4 90 8 1 speed min 1...

Page 7: ...te m3 s 0 41 0 49 0 59 0 9 Effective electric power input kW 0 53 0 76 1 05 1 01 SFPint W m3 s N A N A Face velocity m s 0 0 0 0 Normal external pressure Pa 490 642 781 490 Internal pressure drop of ventilation compo nents Pa N A N A N A N A Static efficiency of fans used in accordance with Regulation No 327 2011 38 1 40 4 44 1 43 8 Declared maximum external leakage 1 1 1 1 Casing sound power leve...

Page 8: ... risk reduction LST EN 60204 1 Safety of machinery Electrical equipment of machines Part 1 General requirements LST EN 60335 1 Household and similar electrical appliances Safety Part 1 General requirements LST EN 60529 Degrees of protection provided by enclosures IP code LST EN 60034 5 Rotating electrical machines Part 5 Degrees of protection provided by the integral design of rotating electrical ...

Page 9: ...uipment to manufacturer Delivery costs should be covered by customer Manufacturer reserves the right to change this technical passport any time without prior notice if some typographic errors or inaccurate information is found as well as after improving the apps and or the devices Such changes will be included in the new issues of the technical passport All illustrations are just for information a...

Page 10: ...10 VKS v2019 04 ...

Page 11: ... 11 VKS v2019 04 ...

Page 12: ...AN000148 UNIT S MAINTENANCE TABLE Product name lot number Instalation Interval Date Fan cleaning Once a year Heat exchanger cleaning Once a year Filter replacement Every 3 4 months Look at the product label At least NOTE The purchaser is required to fill in the Product maintenance table ...

Reviews: