background image

MDP 50  OPERATING INSTRUCTIONS

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 

 

PUMP 

 

MDP 50 

 

OPERATING INSTRUCTIONS 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

SAINT-GOBAIN PERFORMANCE 

 

 SAINT-GOBAIN PERFORMANCE PLASTICS 

PLASTICS  FRANCE 

 

 

 

EADAC DES BERTHILLIERS 

7301 Orangewood Avenue 

F-71850 CHARNAY LES MACON 

Garden Grove, CA 92841 

Tel:  33. (0) 3 85 20 27 00 

Tel: 1(714) 630 5818 

Fax: 33. (0) 3 85 29 18 48 

Fax: 1 (714) 688 2614 

 

www.microelectronics.saint-gobain.com

 

 

Summary of Contents for MDP 50

Page 1: ...INPERFORMANCE SAINT GOBAINPERFORMANCEPLASTICS PLASTICS FRANCE EADAC DES BERTHILLIERS 7301 Orangewood Avenue F 71850 CHARNAY LES MACON Garden Grove CA 92841 Tel 33 0 3 85 20 27 00 Tel 1 714 630 5818 Fax 33 0 3 85 29 18 48 Fax 1 714 688 2614 www microelectronics saint gobain com ...

Page 2: ...III 1 Testing III 2 Set up III 3 Connections III 3 1 Air nitrogen connections III 3 2 Fluid connections III 4 Initial tests and adjustments IV Applications 3 IV 1 Chemical compatibility IV 2 Temperature range IV 3 Cleaning IV 4 Single stroke adjustment IV 5 Limitations of use V Trouble shooting 5 VI Warranty safety 5 Appendix 7 Section view Dimensions Pneumatic wiring diagram ...

Page 3: ...he top of the pump The pump speed varies with operating conditions air pressure viscosity density I 4 Pump data The main characteristics of the MPD 50 pump are Repeatability 1 Dispense volume per shot 0 to 0 5 mL Dispense speed 0 to 0 5 mL s max Delivery pressure 4 3 psig 0 3 bar max at 70 psig 4 8 bar air actuation Air nitrogen pressure 50 70 psig 3 4 4 8 bar Suction height 2 feet 0 6m based on w...

Page 4: ...l valve is to control the speed of the suction cycle The integrated check valve is for a quick release of the pressure during the discharge cycle 3 2 way valve is necessary for the on off cycle of the pump When the 3 2 valve is actuated it is the suction cycle When the 3 2 valve is not actuated it is the discharge cycle Pressure regulator is to setup the right pressure Filter If the air nitrogen o...

Page 5: ...ge line It is recommended to adjust the stem to the maximum stroke 3 Check the delivered volume of liquid with a calibrated beaker test tube or a precision balance to calculate the single stroke 4 If unit stroke is not as required screw on the adjustable stem to reduce the stroke or unscrew it to increase the volume 5 Repeat the stroke until you get the required volume of liquid per shot 6 When th...

Page 6: ...e year from delivery date SGPPL is not responsible for damage to its products through improper installation maintenance use or attempts to operate them beyond their mechanical capability intentionally or otherwise or for unauthorized repair SGPPL shall not be liable for any indirect special incidental or consequential damages resulting from the use failure or malfunction of any product Safety hint...

Page 7: ...ted When the pump is handling liquids higher than 122 F 50 C avoid direct contact with the pump or piping system Use appropriate hand protection if handling of the pump or piping is necessary Always wear protective gear goggles face shield acid resistant gloves etc when removing or servicing the pump In addition flush the pump completely with di water prior to any service or maintenance Ensure suc...

Page 8: ...7 7 ...

Reviews: