background image

2-Sagemcom Internal Information - No outside communication without authorization from appropriate Management  

This document and the information contained are th e property of Sagemcom 

3000499645-01 

Page 4 

WM Installation Manual (EN) 1.0 

 

  NETWORK INSTALLATION 

In order to attach the Water Meter on a network / pairing device: 

Activate the network or the companion device to accept the pairing 

1. 

On the water meter : 

a. 

 

b. 

 

c. 

 

 

d. 

Press twice rapidly on the button to accept the installation process 

e. 

The Water Meter will send an installation request message for pairing. 

f. 

The Water Meter LCD will display a blinking antenna symbol. 

2. 

On the network or the companion device : 

a. 

Check that the pairing info are received and that it corresponds to the Water meter, and accept the pairing 

request. In a network registration, this is automatic if provisionning of the Water meter was  already done into 

the system. 

b. 

On the next installation request message send by the water meter, the network or companion device should 

respond with an installation success message to confirm installation. 

3. 

The Water meter antenna symbol stops blinking. 

 

Safety instructions 

All installations of product must be done according to safety 

regulations and rules. The instructions detailed in this guide 

must be carefully followed in order to prevent from any form 

of danger for the installation, for the installer or for the end 

user. 

 

The following safety instructions must be observed at all 

time: 

 

The installation and commissioning must only be per-

formed by a qualified and trained installer, authorized 

to work on domestic water installations. This Installer 

must carefully read and scrupulously follow this meter 

user manual. 

 

The installation must be conform to the standard for 

drinking water installation. 

 

Local safety regulations must be observed. 

 

The installation altitude wrt to the sea level must be 

lower than 2000m. 

 

The product must be protected from shock and vibra-

tion. 

 

Any inappropriate behaviour not described in this doc-

ument can lead to injuries or damage of the meter.  

 

No part inside this product is intended to be replacea-

ble. 

 

If an installed product is removed from installation and 

intended to shipped through air transportation, the ra-

dio function must be disabled using NFC or other in-

terface. 

 

According to AWWA, even if section 250.53(D) of the 

of the grounding path or bonding connection to interior 

pip

should be installed with permanently ground-strapped 

strap-ping. 

 

Installation instructions 

The installation instructions are the following: 

 

The product must not be exposed to mechanical stress 

during installation. The intake and outcome piping 

must be aligned and match the product pipe dimen-

sion. 

 

The meter can be installed on plastic or metallic pipe, 

after a general closing tap.  

 

During installation of the meter, the water supply must 

be cut and the remaining water flush out. 

 

Do not hold the product casing but the pipe during the 

installation screwing. 

 

Always used new gaskets for mounting the product 

onto the piping. 

 

The torque applied to screw of the product must be 

higher than 15 N.m and not overpass 30 N.m whatever 

the thread and pipe material. 

 

The water supply must be re-opened smoothly, ena-

bling air bubble to be removed without mechanical im-

pact. 

 

The provisioning onto the facility radio network can be 

done using the QR code information written on the 

product. Be aware that this provisioning over the net-

work could required some time to be effective . The 

product cannot register on the network until this provi-

sioning is over. 

 

Once water flows, the radio attachment process starts; 

and it indicates the radio link quality to the network. 

When the antenna icon stops blicking, it shows that the 

network attachment succeed 

 

If radio link after installation is too poor (no bar next to 

the antenna symbol) and if product is so-equipped, an 

external antenna must be installed in a higher place, 

more likely to receive radio signals and then connected 

to the product. It should be activated using the optical 

flag interface or BLE. 

 

2-Sagemcom Internal Information - No outside communication without authorization from appropriate Management  

This document and the information contained are th e property of Sagemcom 

3000499645-01 

Page 1 

WM Installation Manual (EN) 1.0 

 

Installation Manual 

UM20 

SICONIA WATER  

Smart METERs 

 

With LTE LPWAN radio  

 

Optical Port (optional) &  

BLE interface (optional) 

 

 

 

Sagemcom Broadband SAS 

www.sagemcom.com 

 

 

Reviews: