background image

©

 1995-2001 Sabine, Inc.

CONGRATULATIONS!  You now have the state-of-the-art in feedback control. Your Sabine FBX-2020 Feedback Exterminator

® 

— a single channel,

20-bit digital filtering device

 

— gives you automatic real-time feedback control and increases the clarity and volume of your system.

The FBX-2020 incorporates the latest in digital signal processing technology. It automatically senses feedback in a sound system and determines
its pitch. It then places one of 10 Constant  Q micro-filters on the resonating frequency and eliminates the feedback in typically less than one second.

Special features of the FBX-2020:

 An improved algorithm that allows the FBX-2020 to better distinguish the difference between feedback and music

Improved 20-bit digital resolution, providing superior dynamic range and signal-to-noise ratio

10 feedback filters, giving the unit more feedback elimination power for the toughest venues.

ClipGuard™ adaptive clip level control, with TURBO setup mode, increases the effective dynamic range by more than 10dB
and makes setup faster and easier.

Standard FBX features such as lockable fixed filters and switchable 1/10- and 1/5-octave Constant Q filters are also included
and now have convenient front panel switches.

QUICK-START OPERATION

For best results, read all operating instructions before using the FBX-2020.  If you're already
familiar with the FBX or just want a basic overview of FBX operation, this simple quick-start
procedure is for you. More detailed instructions are on page 7 inside this operating guide.

1.

Place the FBX between the output of your mixer and the input of your power amp.

2.

With the master volume down, put the FBX-2020 in active mode (red BYPASS LED off), then
slowly raise the mixer master volume to the point of feedback.

3.

Keep raising the master volume until all of your fixed filters and one dynamic filter are set, then
lower the volume slightly.  (Factory default is nine fixed and three dynamic filters.)  The rest of
the filters continually catch and update new feedback frequencies throughout the program.
You're ready to go.

        

READ THE ENTIRE OPERATING GUIDE FOR COMPLETE INSTRUCTIONS.

V2

OPERATING GUIDE

QUICK-START OPERATION

1

DECLARATION OF CONFORMITY

2

APPLICATION OF COUNCIL DIRECTIVE 2

ABOUT THE FBX-2020

3

F

REQUENCY

 R

ESPONSE

3

W

ORLD

'

S

 B

EST

 F

EEDBACK

 C

ONTROLLER

3

W

HO

 N

EEDS

 FBX?

3

W

HY

 

THE

 FBX?

3

D

IRECT

 H

IT

 

ON

 F

EEDBACK

!

3

A

CTIVE

/B

YPASS

 S

WITCH

4

S

IGNAL

 L

EVEL

4

R

ESET

4

S

ET

 T

OTAL

 N

UMBER

 

OF

 F

ILTERS

4

S

ET

 F

IXED

4

L

OCK

 F

IXED

 F

ILTERS

4

A/C P

OWER

 I

NPUT

4

A

UDIO

 I

NPUTS

 & O

UTPUTS

4

FBX-2020 CONTROLS

4

F

IFTH

 O

CTAVE

4

F

ILTER

 S

TAGE

 A

CTIVITY

4

P

OWER

 S

WITCH

4

F

USE

4

APPLICATION DIAGRAMS

5

FBX S

ETUP

 

FOR

 M

ONITORS

5

FBX S

ETUP

 

FOR

 E

NTIRE

 M

IX

5

FBX S

ETUP

 

FOR

 S

INGLE

 I

NSERT

 P

OINT

6

FBX S

ETUP

 

FOR

 I

NSERT

 S

END

 & R

ETURN

6

FBX-2020

6

OPERATING

6

INSTRUCTIONS

6

W

HERE

 

THE

 FBX 

FITS

 

IN

 

YOUR

 

SOUND

 

SYSTEM

6

NOTE

 

ABOUT

 

GRAPHIC

 

EQUALIZERS

6

U

NDERSTANDING

 FIXED & DYNAMIC 

FILTERS

6

C

LIP

G

UARD

™ A

DAPTIVE

 C

LIP

 L

EVEL

 C

ONTROL

6

C

LIP

G

UARD

TM TURBO M

ODE

 G

UIDE

6

H

OW

 T

O

 O

PERATE

 T

HE

 FBX-2020

7

H

OW

 T

O

 U

SE

 T

HE

 FBX-2020 F

EATURES

8

  U

SING

 

THE

 LOCK FIXED 

FEATURE

8

  S

ELECTING

 

FILTER

 

WIDTH

8

I

MPORTANT

 O

PERATING

 C

ONSIDERATIONS

8

  M

EMORY

8

  B

YPASS

 M

ODE

8

  R

ESETTING

 

THE

 

FILTERS

8

  TURBO M

ODE

 S

ETUP

8

  D

EFEATING

 T

URBO

 M

ODE

8

  M

OBILE

 

VS

. S

TATIONARY

 M

ICROPHONES

8

FREQUENTLY ASKED QUESTIONS

9

INDEX

9

FBX-2020 ENGINEERING SPECIFICATIONS

10

CAUTIONS & WARNINGS

11

LIMITED WARRANTY

12

Summary of Contents for FBX-2020

Page 1: ...input of your power amp 2 With the master volume down put the FBX 2020 in active mode red BYPASS LED off then slowly raise the mixer master volume to the point of feedback 3 Keep raising the master vo...

Page 2: ...rer s Name Sabine Inc Manufacturer s Address 13301 Highway 441 Alachua FL 32615 8544 USA Type of Equipment Equalizer Model No FBX 2020 Serial No Year of Manufacture 1997 and on I the undersigned herby...

Page 3: ...nce FBX filters do not have to be as deep so there is more system gain The most important advantage is that FBX micro filters are ten times narrower than 31 band EQ filters FBX micro filters return up...

Page 4: ...g to the desired number of fixed filters lights press the button to register your selection Factory default is nine fixed and three dynamic filters Lock Fixed Filters When the LOCK FIXED button is pre...

Page 5: ...5 APPLICATION DIAGRAMS FBX Setup for Entire Mix FBX OUT Main OUT FBX IN Amp IN Amplifier All other Signal Processing Equipment FBX Setup for Monitors Monitor OUT FBX IN FBX Out Amp In Amplifier...

Page 6: ...y to differ ent frequencies as new feedback occurs during the program For most applications the optimal setting is nine FIXED and three DYNAMIC FILTERS This is the factory default ClipGuard Adaptive C...

Page 7: ...volume level of the feedback duringsetup TheFBX 2020issetinTURBOmodeatthefactory andautomaticallyengageseverytimeyoupressRESETorSET TOTAL NO to reset filters or set total number of filters The FBX 202...

Page 8: ...e cuts the time for FBX filter initialization to just a few seconds and it reduces the volume level of the feedback during setup The 2020 is set in TURBO mode at the factory and automatically engages...

Page 9: ...ps significantly below 10 of the specified voltage Check the A C power mains Q Why does my system sound thin and muffled A Place the FBX in BYPASS MODE If the system still sounds thin your problem is...

Page 10: ...al Variation 25 dB 20Hz to 20 KHz SNR 100 dB typical A weighted NOTES 1 Below approximately 200 Hz the feedback filters become slightly wider to increase the feedback and rumble capture speed at these...

Page 11: ...the dealer or an experienced radio TV technician for help Canadian Compliance Statement This digital apparatus does not exceed the Class B limits for radio noise emissionsfromdigitalapparatussetoutint...

Page 12: ...onal injury or damage to real property or tangible personal property allegedly caused by Sabine s negli gence Sabine does not assume liability for personal injury or property damage arising out of or...

Reviews: