manualshive.com logo in svg
background image

V+ Series

 OPERATING INSTRUCTIONS

Before using this , be sure to read this OPERATING
INSTRUCTIONS  thoroughly  to  ensure  proper  operation.
Make sure that the delivered unit conforms to your requirement,
and also check for any missing or damaged parts.
Instruction manuals as below are available upon request from your
nearest  sales  office.

Accessories  furnished  with  this  unit:
[Accessories]

  OPERATING  INSTRUCTIONS 1  copy

*

e

c

p

 

1

p

m

a

l

C

 

e

l

b

a

C
Neck  Strap

1  pce*

 

2

s

w

e

r

c

S

pcs (M3 x 10) *

* About mounting procedure, refer to "Specifications for ."

Models

Comply with CE/UL/cUL

106

POWER

SW1

SW4

SW3

SW2

F3

F2

F1

F7

F6

F5

F4

SYSTEM

ENB

47

24

259

232

Top View

Front View

Side View

Bottom View

Rear View

unit : mm

Names  of  Components

Front Side

1. Deadman switch / 3-position switch
2. Emergency Stop switch
3. ENB lamp
4. Function keys
5. Output (to outside) switches
6. Display
7. Power lamp
8. Key switch (option)

TB1

MJ1

SW1

POWER

SW1

SW4

SW3

SW2

F3

F2

F1

F7

F6

F5

F4

SYSTEM

ENB

9. Terminals for PLC communication, power

supply and output (to outside)

10. MJ1: for data transfer
11. SW1: Terminal resistance(upper:on)
12. Mounting holes for cable clamp and

neck strap

13. Mounting holes for wall-mounting fixture

(V6H-WF+:option)

14. Connector for battery (V6H-RB+:option)

maintaining the data of built-in clock

Specifications

P

ow

er Supply

P

hysical E

nvironment

Mechanical W

or

king

Conditions

Elect

rical

W

or

king

Conditions

Mounting Conditions

Item

Type

Rated Voltage

Permissible Range of Voltage

Permissible Momentary Power Failure

Demand

Rushed Electric Current

With-stand voltage

Insulation Resistance

Ambient Temperature

Storage Ambient Temperature

Ambient Humidity

Dust

Solvent Resistance

Corrosive Gas

Vibration Resistance

Shock Resistance

Noise Resistance

Static Electricity Discharge Resistance

Grounding

Structure

Protection structure: front panel complies with IP65
 

 

(except /)

Form: in a body
Mounting procedure: hand-held, wall-mounted, tabletop

500V DC, 10M    or more

0    ~+50

-10    ~+60

85% RH or less (without dew condensation)

No conductive dust

No cutting oil or no organic solvent to cling to the unit

No corrosive gas

Vibration frequency: 10~150Hz, Acceleration: 9.8m/s  (1.0G)

3 directions of X, Y and Z: one hour

Pulse shape: Sine half wave,

Peak acceleration: 147m/s  (15G), 3 directions of X, Y and Z: six times

Noise voltage: 1000Vp-p, noise width: 1   s

Contac: 6kV , Air: 8kV

Grounding resistance: less than 100

Cooling naturally

Approx. 1.2kg

259 X 232 X 47 (except the size of Emergency Stop switch)

the Munsell color system N-2.0 (BLACK)

PC/ABS

24V DC

24V   10% DC

within 10ms (24VDC)

20W or less  

13A, 2ms

DC external terminals to FG : 500V AC per min.      

(mm)

2

2

Cooling System

Weight

Dimensions W X H X D

Case Color

Material

Notes on Safe Usage

In this " OPERATING INSTRUCTIONS," you will find
various notes categorized under the following two levels with the
signal words "Danger" and "Caution."

Indicates an imminently hazardous situation which, if
not avoided, will result in death or serious injury.

Indicates a potentially hazardous situation which, if
not avoided, may result in minor or moderate injury
and  could  cause  property  damage.

DANGER

CAUTION

TB1

This terminal block is used for communication with PLC, power supply
and output to outside.
The pin arrangement is as follows:

Dimensions

Other  Specifications

Screw Size

M2

Torque

0.22 - 0.25N m

Solid wire

0.14 - 1.5mm

2

Stranded wire

0.14 - 1.0mm

2

Rear Side

wire,  inspect,  and  maintain  the  product.

Maintain  the  following  conditions  in  order  to  avoid  fire  or  trouble.

-Do  not  let  the  unit  come  in  contact  with  water,  corrosive  gas,  flammable  gas,

solvents,  grinding  fluids  or  cutting  oil.

-Never  let  the  unit  be  exposed  to  high  temperature,  high  humidity,  and  other

outside  weather  conditions.

-Do  not  allow  the  unit  to  be  exposed  to  excessive  dust,  salt,  and  metallic

particles.

-Do  not  allow  the  unit  to  be  shaken  or  hit  by  other  objects.

Connect  the  cables  correctly  to  the  terminals  of  AnyTouch  in  accordance  with

the  specified  voltage  and  wattage.  Over-voltage,  over-wattage  and  the  incorrect
cable  connection  could  cause  the  unit  to  be  damaged  physically  or  functionally
and  also  could  result  in  fire.

Equipment  must  be  correctly  mounted  so  that  the  main  terminal  will  not

inadvertently  be  touched  during  an  application.

Tighten  terminal  block  screws  with  the  following  torques.

Prevent  any  conductive  particles  from  entering  into  AnyTouch.    The  conductive

particles  could  cause  fire,  trouble,  or  malfunction  of  the  unit.

Never  bundle  input/output  cables  with  high-voltage  and  large-current  cables  such

as  power  supply  cables.    Keep  input/output  cables  at  least  200mm  away  from
power  supply  cables  in  order  to  avoid  malfunction  caused  by  noise.

This  equipment  must  be  earthed.    Ground  FG  terminal  which  must  be  for  the  unit.

The  level  of  grounding  resistance  is  less  than  100

.

Do  not  press  the  keypad  switches  with  sharp-pointed  tools.
Application  of  thinner  may  discolor  AnyTouch.    Use  alcohol  or  benzine  available

commercially  for  cleaning.

RS  Automation  Co.,  Ltd.  is  not  responsible  for  an  unauthorized  person  who  may

fix,  disassemble,  or  reconstruct  any  unit.

As  for  the  use  in  the  facilities  related  to  nuclear  energy  or  in  the  facilities  of

official  importance,  please  consult  with  our  distributer  about  it.

Follow  the  regulations  of  industrial  wastes  when  the  device  is  to  be  discarded.
Do  not  press  two  or  more  points  on  a  screen  at  the  same  time.    This  may  active

a  switch  located  between  the  points  pressed.

Avoid  display  the  same  patterns  for  hours.

It  may  cause  afterimages  due  to  the  property  of  LCD  display.    If  you  use  the
fixed  patterns  for  hours,  use  the  auto-OFF  function  of  the  backlight.

   

Deadman Switch 

Key Switch

  0 

Momentary 

None

  1 

Momentary 

Provided

  2 

3-position 

None

  3 

3-position 

Provided

Side

Bottom

15. CF card interface
16. Mounting holes for communication cable

TB1

MJ1

SW1

TxD

RxD +SD -SD +RTS -RTS D01 D03 COM- EMG1 EMG2 +24V

0V

RTS CTS

SG

+RD -RD +CTS -CTS D02

D04 E_COM KEY1 KEY2 FG

TB1

Signal

KEY2

TXD

RXD

SG

+24V

0V

+SD

-SD

+RTS

-RTS

Contents

Key switch 2

RS-232C send data

RS-232C recieve data

Signal ground

RS-485 send data (+)

RS-485 send data (-)

RS-485 control signal

RS-485 control signal

RTS

CTS

RS-232C control signal

RS-232C control signal

Power supply for 

0V

+CTS

-CTS

RS-485 control signal

RS-485 control signal

+RD

-RD

RS-485 recieve data (+)

RS-485 recieve data (-)

D01

D03

COM-

EMG1

EMG2

Output SW1

Output SW3

Output common

Emergency stop 1

Emergency stop 2

D02

D04

Output SW2

Output SW4

E_ COM

FG

Frame ground

KEY1

Key switch 1

Emergency stop 1, 2 common

Signal

Contents

Emergency Stop switch

Deadman switch

3-position switch
(option)
Key switch (option)

Item

Type

Push-lock type

Two B-contacts, single common

Momentary

Single A-contact

3-position

Single A-contact (double interrupting, slow action)

Single A-contact

Form

Contacts composition

Form

Contacts composition

Form

Contacts composition

Number of contacts

Even some items indicated "

CAUTION

" may also result in a serious

accident.

DANGER

Never  use  the  input  function  of  AnyTouch  such  as  the  touch  switch  (except

Emergency  Stop  switch)  for  an  emergency  switch  because  it  could  threaten  a
human  life  or  break  a  part  of  the  unit.
Please  design  the  system  of  the  unit  in  order  to  respond  to  a  malfunction  of  the
touch  switch.

Never  touch  the  terminals  while  the  power  supply  is  on,  otherwise  you  will  get  an

electric  shock.

Turn  off  the  power  supply  when  you  set  up  the  system,  connect  the  cables,

maintaining  or  checking,  otherwise  you  will  get  an  electric  shock  or  damage  the
unit.

The  liquid  (liquid  crystal)  on  the  liquid  crystal  display  is  harmful.    If  it  has  been

damaged,  it  must  not  get  into  the  mouth.    If  the  skin  or  clothes  are  stained  with
in,  rinse  them  with  soapy  water.

CAUTION

Operate  AnyTouch  under  the  conditions  indicated  by  OPERATING

INSTRUCTIONS  or  relevant  manual.
If  you  do  not  set  the  conditions  indicated  by  the  manual  for  the  unit,  it  could
cause  fire,  malfunction,  physical  damage  or  deterioration.

Do  not  use  the  one  found  damaged  or  deformed  when  unpacked.
AnyTouch  has  a  glass  screen.    Never  drop  or  subject  the  unit  to  strong  impacts.
Only  a  qualified  person  with  the  necessary  technical  knowledge  should  install,

Publication

RS Automation Co., Ltd.

3341NKO

Отзывы: