background image

SUBJECT:

  Coin Changer Fit and Coin Chute Adjustment in GIII CDC

MODELS:

  GIII CDC

TOOLS REQUIRED:

  N/A

ESTIMATED TIME:

  N/A

ANY QUESTIONS?  

CONTACT ROYAL VENDORS’ CUSTOMER SERVICE DEPARTMENT

IN NORTH AMERICA, CALL TOLL FREE 1 800 931 9214

F0019077.FRM      

                                                                                        REV.:  A

ISSUE DATE:  23 MAR 2000 

REV. DATE:  23 MAR 2000

075

INFORMATION:

  

This document describes the procedure for properly fitting 

the changer in GIII CDC venders, as well as proper coin chute adjustment.

Wide Port Venders 

(serial numbers 200015AA00421 and after)

:

R

Page:

 1 of 2

Date:

 23 Mar 2015

Revision:

 00

Number of 

People 

Required

R

426 Industrial Boulevard • Kearneysville WV  25430-2776 • USA

Telephone:

 +1 304 728 7056 • [email protected]

Toll-free in North America:

 1 800 931 9214 • 

Fax:

 +1 304 725 4016

Canada:

  +1 905 738 5777 • 

Mexico:

  +52 55 5203 6887

Europe:

  +49 2158 95 1000 • 

Australia:

  +61 2 9890 5433

The  following  areas  of  this  vender  contain  voltage  which  can 

cause  serious  injury  or  even  death:    the  main  power  cord, 

supplying  115-230  VAC  to  the  evaporator,  EMI  filter, 

refrigeration  system,  monitor,  and  computer;  the  power  line 

from  the  EMI  filter  to  the  ballast  and  transformer;  and  the 

ballast,  which  can  produce  upwards  of  600  volts.    Remove  all 

power  from  the  vender  before  working  in  any  of  these  areas.

1.  Ensure the coin chute is clean, with no dirty or sticky debris 

present.

2.  Ensure the coin deflector ("race car") is correctly installed 

(pointed out in yellow in Figure 1).  Also ensure the wire tie 

(red arrow) is present to secure the coin deflector.

Figure 1.

  The coin deflector should be properly installed with its 

tabs (pointed out with yellow arrows) inserted in the holes at the 

end of the coin chute assembly.

3.  Adjust the coin chute in and out using the adjustment screw 

pointed out in yellow in Figure 2.  The coin chute should be 

centered above the changer hopper.

Figure 2.

  In and out adjustment screw.

4.  Adjust the coin chute up and down using the vertical adjustment bracket, pointed out in yellow in Figure 3.  The gap between the 

end of the coin chute and the changer hopper should be no more than 

3

/

16

" (5 mm), as shown in Figure 4.

Figure 3.

  Vertical adjustment bracket.

Figure 4.

  The gap should be no more than the one shown here.

Reviews: