background image

Thank you very much for purchasing this product.

•  To ensure correct and safe usage with a full understanding of this product's performance, please be sure to read through 

this manual completely and store it in a safe location.

•  When purchasing, please ensure that the stamp and address of your authorized Roland DG Corp. dealer, as well as the 

date of purchase, are filled in on the Warranty and please store this Warranty in safe place.

•  Unauthorized copying or transferal, in whole or in part, of this manual is prohibited.
• 

The specifications of this product and the contents of this operation manual are subject to change without notice.

• 

The documentation and the product have been prepared and tested as much as possible. If you find any misprint or error, 

please inform us.

•  Roland DG Corp. assumes no responsibility for any direct or indirect loss or damage that may occur through use of this 

product, regardless of any failure to perform on the part of this product.

•  Roland DG Corp. assumes no responsibility for any direct or indirect loss or damage that may occur with respect to any 

article made using this product.

User's Manual

Auxiliary Drying Unit

R4-180111

Summary of Contents for DU2-54

Page 1: ...r in part of this manual is prohibited The specifications of this product and the contents of this operation manual are subject to change without notice The documentation and the product have been prepared and tested as much as possible If you find any misprint or error please inform us Roland DG Corp assumes no responsibility for any direct or indirect loss or damage that may occur through use of...

Page 2: ...MB 3 A For Canada The importer in the EU Roland DG Europe Holdings B V Prof J H Bavincklaan 2 1183 AT Amstelveen The Netherlands Manufacturer ROLAND DG CORPORATION 1 6 4 Shinmiyakoda Kita ku Hamamatsu shi Shizuoka ken 431 2103 JAPAN For EU Countries For California WARNING This product can expose you to chemicals including lead which is known to the State of California to cause cancer and birth def...

Page 3: ...e Arms for EJ 640 21 Step 2 Installing the Drying heater Unit Common for All Models 22 Step 3 Installing the Blower fan Unit for VG 640 540 EJ 640 23 Step 3 Installing the Blower fan Unit for XF 640 25 Connecting the Cables 28 When VG 640 540 is Used 28 When EJ 640 XF 640 is Used 29 Chapter 2 BasicOperation 31 Drying heater Unit Operation 32 What to Do First 32 Switching the Power On and Off 33 Se...

Page 4: ...d all its furnishings as well as to domestic animals or pets About the Symbols The symbol alerts the user to important instructions or warnings The specific meaning of the symbol is determined by the design contained within the symbol The symbol at left means danger of electrical shock The symbol alerts the user to items that must never be carried out are forbidden The specific meaning of the symb...

Page 5: ... like use only genuine articles compatible with this ma chine Incompatible articles may lead to an acci dent Before attempting cleaning maintenance or attachment or detachment of optional items disconnect the power cord Attempting such operations while the ma chine is connected to a power source may result in injury or electrical shock Never attempt to disassemble repair or modify the machine Doin...

Page 6: ...ed Using a damaged article may result in fire or electrical shock WARNING When using an extension cord or power strip use one that adequately satisfies the machine s ratings for voltage frequency and current Use of multiple electrical loads on a single electrical outlet or of a lengthy extension cord may cause fire Connect to ground This can prevent fire or electrical shock due to current leakage ...

Page 7: ...ject on top of or subject the power cord to damage Never allow the power cord to get wet Never bend or twist the power cord with excessive force Never subject the power cord to heat Never pull the power cord with excessive force Dust may cause fire Never bundle bind or roll up the power cord ...

Page 8: ...to the machine to make areas of danger immediately clear The meaning of this label is indicated below Be sure to heed this warning Also never remove the label or allow it to become dirty Caution High Temperature The dryer becomes hot Exercise caution to avoid fire or burns Keep the fingers and face away from the blower fan Fingers or hair may become entangled resulting in injury Warning label ...

Page 9: ...ous les meubles et même les animaux domestiques À propos des symboles Le symbole attire l attention de l utilisateur sur les instructions importantes ou les aver tissements Le sens précis du symbole est déterminé par le dessin à l intérieur du triangle Le symbole à gauche signifie danger d électrocution Le symbole avertit l utilisateur de ce qu il ne doit pas faire ce qui est interdit La chose spé...

Page 10: ... d alimentation et autres articles semblables compatibles avec l appareil Les articles incompatibles risquent de causer des accidents Débrancher le câble d alimentation avant de procéder au nettoyage ou à l entretien de l appareil et avant d y fixer ou d en retirer des accessoires en option Tenter ces opérations pendant que l appareil est branché à une source d alimentation peut causer des blessur...

Page 11: ... d alimentation la fiche et la prise électrique correctement et avec soin Ne jamais utiliser un article endommagé car cela pourrait causer un incendie ou un choc électrique ATTENTION Si une rallonge ou une bande d alimentation électrique sont utilisées s assurer qu elles correspondent aux caractéristiques de l appareil tension fréquence et courant Ne jamais utiliser un article endommagé car cela p...

Page 12: ...a risque de les endommager Ne jamais laisser l eau toucher le câble la fiche ou la prise Ne jamais plier ni tordre le câble avec une force excessive Ne jamais chauffer le câble la fiche ou la prise Ne jamais tirer sur le câble ou la fiche avec une force excessive La poussière peut causer un in cendie Ne jamais plier ni enrouler le câble Pour utiliser en toute sécurité 10 ...

Page 13: ...de repérer les zones dangereuses La signification des vignettes est donnée ci dessous Respecter les avertissements Ne jamais retirer les vignettes et ne pas les laisser s encrasser Tenir les doigts et la tête loin du ventila teur soufflant Les doigts ou les cheveux pourraient être coincés ou s emmêler ce qui causerait des blessures Attention Température élevée La platine et la surface de séchage c...

Page 14: ...12 ...

Page 15: ...Step 1 Attaching the Arms for VG 640 540 17 Step 1 Attaching the Arms for XF 640 19 Step 1 Attaching the Arms for EJ 640 21 Step 2 Installing the Drying heater Unit Common for All Models 22 Step 3 Installing the Blower fan Unit for VG 640 540 EJ 640 23 Step 3 Installing the Blower fan Unit for XF 640 25 Connecting the Cables 28 When VG 640 540 is Used 28 When EJ 640 XF 640 is Used 29 13 ...

Page 16: ...ng air against the surface of the media An electrical outlet separate from that for the printer is required in order to use the drying heater unit Compatible Models As of August 2017 VG 640 540 EJ 640 XF 640 The printer and the drying heater unit require separate high capacity electrical outlets Make sure to connect the two power cords to outlets on separate systems Also make sure that the electri...

Page 17: ...on panel are indicated as shown below Part Name Description Notation in this manual Cursor keys Use these to select settings for menu items to move the media and for other such operations SETUP SETUP light SETUP key The light turns on when media has been loaded correctly The key is used to load the media SETUP ENTER ENTER key Use this for such tasks as enabling setting val ues ENTER MENU MENU key ...

Page 18: ...right and left Arm B large 1 each for right and left Arm B small 1 each for right and left Stay 1 each for right and left Power cord 1 Power plug adapter 1 Washer 4 Bolt 14 Cable clamp 4 User s Manual this document 1 Bushing 1 Hexagonal wrench 1 Included Items ...

Page 19: ...tep 3 Installing the Blower fan Unit for XF 640 EJ 640 P 21 Step 1 Attaching the Arms for EJ 640 P 22 Step 2 Installing the Drying heater Unit Common for All Models P 23 Step 3 Installing the Blower fan Unit for VG 640 540 EJ 640 Step 1 Attaching the Arms for VG 640 540 Included Items Required Arm A Arm B large Procedure A Assemble the left and right arms by referring to the figures below After ti...

Page 20: ...e C Attach the arms with the bolts removed in step B Use the back screw holes as seen from the front Arm left Arm right D Attach the cable clamps to the arm right Cable clamp This completes the procedure for attaching the arms P 22 Step 2 Installing the Drying heater Unit Common for All Models ...

Page 21: ...s below After tightening the bolts temporarily tighten them completely two bolts for each arm MEMO There is no right left distinction in arm assembly parts However arms assembled for the right or left side are treated as right or left arms respectively Arm right Arm left Bolt Bolt Hexagonal wrench Hexagonal wrench B Remove two bolts from each of the positions shown in the figure ...

Page 22: ...s removed in step B Use the front screw holes as seen from the front Arm left Arm right D Attach the cable clamps to the arm right Cable clamp This completes the procedure for attaching the arms P 22 Step 2 Installing the Drying heater Unit Common for All Models ...

Page 23: ... use the items included with the EJ 640 not the items included with the DU2 64 Procedure A Attach the arms to the tabletop plates on the stand legs Arm Arm B Attach the cable clamps to the arm right Cable clamp This completes the procedure for attaching the arms P 22 Step 2 Installing the Drying heater Unit Common for All Models ...

Page 24: ... the drying heater unit on the arms Place it oriented as shown in the figure Rest on the hooks Drying heater unit cable Rest on the hooks Hook B Temporarily secure the drying heater unit Attach the drying heater unit to the arms and temporarily secure it using two bolts with at tached washers on both the right and left sides Drying heater unit Washer Bolt Arm ...

Page 25: ...ed to the next step according to the model you are using P 23 Step 3 Installing the Blower fan Unit for VG 640 540 EJ 640 P 25 Step 3 Installing the Blower fan Unit for XF 640 Step 3 Installing the Blower fan Unit for VG 640 540 EJ 640 The VG 640 is used for the figures of the printer Procedure A Attach the stays The stays for the left and right are different Attach them in the orientation shown i...

Page 26: ...Installing on the Printer 24 B Install the blower fan unit Remove the tape Attach the hooks to install Blower fan unit Blower fan unit Blower fan unit C Attach the bushing to the stay right Bushing ...

Page 27: ... unit are already at tached Bundle and secure with the auxiliary drying unit cable Cable clamp This completes the procedure for installing on the printer P 28 Connecting the Cables Step 3 Installing the Blower fan Unit for XF 640 Procedure A Remove the left and right covers Press the part in the following figure until it clicks Lightly pull the cover in the direction indi cated with 1 and then rem...

Page 28: ...r the left and right are different Attach them in the orientation shown in the figure Stay left Stay right There is a hole in the stay right C Install the blower fan unit Remove the tape Blower fan unit Blower fan unit Attach the hooks to install Blower fan unit ...

Page 29: ... locations of the frame right as the cable clamps for the auxiliary drying unit are already at tached Bundle and secure with the auxiliary drying unit cable Cable clamp Drain bottle F Attach the left and right covers 1 Hang the cover on the hook and pull down in the direction indicated by 2 Press the part in the following figure until it clicks Click This completes the procedure for installing on ...

Page 30: ...k with all power switches left switched off Failure to observe this instruction may cause the machine to move suddenly resulting in injury The printer and the drying heater unit require separate high capacity electrical outlets Make sure to connect the two power cords to outlets on separate systems Also make sure that the electrical outlets meet the machine s ratings When VG 640 540 is Used Connec...

Page 31: ... fan unit cable Blower fan unit Drying heater unit cable When EJ 640 XF 640 is Used Connect the drying heater unit and blower fan unit cables and the power cord Power cord Power cord connector Drying heater unit Blower fan unit cable Drying heater unit cable Electrical outlet Blower fan unit Blower fan unit connector Drying heater unit connector Drying heater unit cable Blower fan unit cable ...

Page 32: ...30 ...

Page 33: ...eration Drying heater Unit Operation 32 What to Do First 32 Switching the Power On and Off 33 Setting the Drying Heater Unit Temperature 33 Blower fan Unit Operation 34 Turning On the Power of the Blower fan Unit 34 31 ...

Page 34: ...urned on 手順 A Press MENU B Press several times to display the screen shown below Press MENU HEATER MENU C Press several times to display the screen shown below Press HEATER MENU OPTION DRYER D Use to select ENABLE Press ENTER OPTION DRYER DISABLE ENABLE E Press MENU then to go back to the original screen Removing This Machine Select DISABLE in the OPTION DRYER menu and switch off the power before ...

Page 35: ...it Temperature The drying heater unit temperature is normally set to the same temperature as the printer unit dryer To change the drying heater unit temperature please adjust the temperature of the printer unit dryer 手順 A Press FUNCTION B Press several times to display the screen shown below Press FUNCTION HEATER CONFIG C Press or to select DRYER Press HEATER CONFIG DRYER 38 C D Use to make the se...

Page 36: ...urning simultaneously when printing starts The blower fan unit automatically stops when printing ends 手順 A Press MENU B Press several times to display the screen shown below Press MENU HEATER MENU C Press several times to display the screen shown below Press HEATER MENU BLOWER FAN D Use to select ENABLE Press ENTER BLOWER FAN DISABLE DISABLE E Press MENU then to go back to the original screen Remo...

Page 37: ... 3 Appendix What to Do If 36 The Drying heater Unit Doesn t Get Hot 36 The Blower fan Unit Doesn t Run 36 If a Message Appears 36 Locations of the Power Rating and Serial Number Labels 37 Specifications 38 35 ...

Page 38: ... Off Is the temperature of the room too low Use the machine in an environment where the temperature is 20 to 32 C 68 to 90 F The Blower fan Unit Doesn t Run Is the blower fan unit cable connected Connect the blower fan unit cable to the printer unit P 28 Connecting the Cables Is BLOWER FAN on the printer set to ENABLE The blower fan unit doesn t operate unless this is set to ENABLE Check the setti...

Page 39: ...hen you seek maintenance servicing or support Never peel off the label Power Rating Use an electrical outlet that meets the requirements for voltage frequency and amperage given here Locations of the Power Rating and Serial Number Labels ...

Page 40: ...rms bushings cable clamps stays hexagonal wrench bolts washers User s Manual 1 Warm up is required after power up This may require 5 to 20 minutes depending on the operating environment Depending on the ambient temperature and media width the preset temperature may fail to be reached 2 Be sure to connect the machine to an unshared electrical circuit 3 Operating environment Use in an operating envi...

Page 41: ... la raccolta differenziata non buttare nel cestino dei rifiuti casalinghi Este producto debe devolverse al centro de reciclaje más cercano a su domicilio para su correcta eliminación No lo tire a la basura Deite fora separadamente este produto no seu centro de reciclagem local Não o deite fora no seu caixote do lixo Lever dit product in bij een lokaal afvalverzamelpunt NIET met normaal huishoudeli...

Page 42: ......

Reviews: