(EMC, LVD)

NT55

Instruction Manual

www.rodemic.com

Summary of Contents for NT55

Page 1: ... EMC LVD NT55 Instruction Manual www rodemic com ...

Page 2: ...ne exhibiting a wide dynamic range and full frequency response The NT55 circuit incorporates a three position variable PADwith0 10or20dBattenuation andathreeposition variable high pass filter that enables you to step from a flat response to 75 or 150 Hz high pass filter The NT55 is intended for film television broadcast live performance theatre surround and environmental recording applications or ...

Page 3: ...vity 38dB re 1V Pa 1kHz 12 6mV Pa 94dB SPL 2dB 1kHz Equivalent Noise 15dBA SPL per IEC651 Maximum Output 8dBu 1kHz 1 THD into 1kΩ Dynamic Range 121dB per IEC651 Maximum SPL 136dB 146 156dB using PAD 1kHz 1 THD into 1kΩ Signal Noise 79dB SPL 1kHz rel 1Pa per IEC651 Power Requirement Phantom P48 Output Connection 3 pin XLR Net Weight 100g Dimensions 145 x 20 x 20mm ...

Page 4: ...tave HPF 150Hz 12dB Octave ä ä ÓÇä näÂ Ó ä Óä ä Ê ä äÊÊ ä ä Ó ä ä È ä n ä ä ä Ó ä ä È ä n ä Óä ä ÓÓ ä Ó ä Óx ä ÊÀi Ê 6É x ä ÀiµÕi VÞ Ê xääÊ â äääÊ â äääÊ â 0 90 270 180 2 0 20 0 10 0 0 0 2 0 4 0 6 0 8 0 10 0 12 0 14 0 16 0 18 0 20 0 22 0 24 0 25 0 dB rel 1V Pa 5 0 Frequency 500 Hz 1000 Hz 4000 Hz ...

Page 5: ...n High Pass Filter 0 75 150Hz Cardioid or Omni polar pattern using interchangeable capsule Full frequency response Designed manufactured in Australia Full 10 year guarantee Accessories Online product registration required Single Matched Pair RM5 stand mount 2 x RM5 stand mount NT45 O Omni capsule 2 x NT45 O Omni capsule Custom case RC5 Hard case ...

Page 6: ...e easily unscrewed from the NT55 body Take extra care with the body and capsule when they are apart and avoid exposure to any moisture and dust Always store all components in the case provided Replace the desired capsule onto the body by screwing it into position Changing the capsules Cardioid NT45 C and Omni NT45 O capsules are also available separately and are compatible with RØDE NT4 NT5 NT55 a...

Page 7: ...n colour They can easily be re used by placing them in an oven at 100 150 degrees celsius for approximately ten minutes The crystals will operate effectively again once they have turned blue Storage Powering the NT55 For optimum performance the NT55 requires a P48 phantom power supply 48 Volt DC Most professional mixing consoles have an internal 48 V supply alternatively you can purchase a separat...

Page 8: ...actory authorised service return will be organised by that dealer We have an extensive distributor dealer network but if you have difficulty getting the advice or assistance you require do not hesitate to contact us directly Microphones International 107 Carnarvon Street Silverwater NSW 2128 Australia Ph 61 2 9648 5855 Fax 61 2 9648 2455 USA P O Box 4189 Santa Barbara CA 93140 4189 Ph 805 566 7777...