background image

Description:

 

 

Robinhood Gas Cooktop 60cm and 90cm 

Model Numbers: 

HGA604FKSS, HGA905FKSS 

Issue 8
 

 

TO BE INSTALLED BY AN AUTHROISED PERSON 

 

THESE INSTRUCTIONS CONTAIN IMPORTANT 

INFORMATION ABOUT INSTALLATION AND USE 

Summary of Contents for HGA604FKSS

Page 1: ...cription Robinhood Gas Cooktop 60cm and 90cm Model Numbers HGA604FKSS HGA905FKSS Issue 8 TO BE INSTALLED BY AN AUTHROISED PERSON THESE INSTRUCTIONS CONTAIN IMPORTANT INFORMATION ABOUT INSTALLATION AND USE ...

Page 2: ...touching the burners To avoid burns and scalds keep children away The cooktop is intended for installation into a benchtop above a kitchen cabinet of min 600mm width or more Incorporation of a oven under the cooktop is permissible for ovens equipped with a cooling fan If the power supply cable is damaged it must be replaced by the manufacturer or its service agent or similarly qualified person to ...

Page 3: ...eps 1 to 3 if the flame does not ignite 1 The OFF position is identified by a black dot To shut off a burner depress the control knob and turn the knob clockwise to the OFF position Using the Burners For greater efficiency and less gas consumption use pots and pans with the right diameters for the burners Avoid having flames extending out from underneath the pans see table Automatic Safety Valves ...

Page 4: ...Operating Instructions ...

Page 5: ...nge and soapy water or non abrasive products Burners and Grids These parts can be removed and cleaned with appropriate products After cleaning the burners and their flame distributors must be well dried and correctly replaced It is very important to check that the burner flame distributor F and the cap C has been correctly positioned fig 6 failure to do so can cause serious problems Check that the...

Page 6: ...ctly positioned and must be engaged in the lodgement as shown by the arrow fig 7 In the correct position the burner must not rotate fig 8 Position the cap A and the ring B as shown in fig 8 Cleaning the Triple Ring Burner Pay special attention to this burner as the four holes around the outside of the crown must always be kept clean When cleaning remove the flame divider fig 9 and use a cotton bud...

Page 7: ...Installation Cutout Dimensions 650mm 30mm 50mm ...

Page 8: ...extractor hood positioned immediately above It is essential to install a heat baffle between the bottom of the cooktop and the underlying unit Installation in Kitchen Cabinet with Door fig 13 The fixture has to be made according to specific requirements in order to prevent the gas burners from going out even when the flame is turned down to minimum due to pressure changes caused by opening or clos...

Page 9: ...a Commissioning test point pressure is with all burners on large flame Gas Connection The appliance is predisposed and adjusted to operate with the gas indicated on the gas type label applied to the underside of the appliance This appliance is pre set at the factory for Natural Gas If the appliance must be operated with a gas different than that indicated on the gas type label it is necessary to e...

Page 10: ...rmanent deformation and should be able to be inspected along its entire length The supply connection point shall be accessible with the appliance installed After connecting to the mains check that the couplings are tight Never use a naked flame to check for gas leaks The connection with rigid pipes should not cause stresses to the appliance inlet and manifold Before Leaving Check all connections f...

Page 11: ...wer supply must be carried out by a qualified technician following the appropriate safety regulations Before carrying out the connection to the power supply the voltage rating of the appliance must be checked for correspondence to the available mains supply voltage the mains electric wiring should also be capable of handling the hob s power rating The power point must be connected to suitable eart...

Page 12: ...he cross section of the electric cables on the power point match the appliances power rating Replacing the Power Supply Cable Use the same type of power supply cable The cable must be connected to the terminal block following the diagram fig 23 Supply cables Type H05V2V2 F resistance to temperatures of 90 C Connection to good earth wiring system is absolutely essential The manufacturer accepts no ...

Page 13: ... from or are due to Exposing the product to acidic or corrosive materials or chemicals such as dyes solvents denture cleaner or acetone Using inappropriate household cleaning products such as abrasive cream or powder cleansers furniture polish bleach mentholated spirits drain cleaners sugar soap metal pads and strongly alkaline or acidic cleaners Heat damage including from washing the product at h...

Page 14: ...mited 76 Postle Street Coopers Plains QLD 4108 within 7 days of any alleged defect or failure of the product first becoming apparent you are responsible for the expense of making a claim under this warranty This warranty is given by Robinhood Australia Pty Ltd ABN 83 004 568 138 Telephone 1800 648 556 Facsimile 1800 628 577 Email enquiries robinhood com au www robinhood com au Attention Customer S...