manualshive.com logo in svg
background image

Compact scanning device 

Photonic Satellite

Operation manual

Содержание Photonic Satellite

Страница 1: ...Compact scanning device Photonic Satellite Operation manual...

Страница 2: ...ng concept universal versatility with ease of operation Whether you are using surface probes single probes or laser needles with the efficient Phy siolaser you will always have the newest therapy prog...

Страница 3: ...re the line moves up and down on an rectangle Once you tip to the form you will reach the screen Adjust Photonic where you can change the basic form and speed of the movement On the screen Select Form...

Страница 4: ...e of all forms ex cept the point Witht he arrow buttosn you can change the size of the form for horizontal orvertical dimension For example you may change the circle to an ellypse The pilot beam 5mW c...

Страница 5: ...active the knobs offer the same function as above Left turn slows down and right turn increa ses the speed Photonic 500 Photonic 500 Stand by Ready Service Aux Power Laser Test Memory card Movable fo...

Страница 6: ...ton refers to right knob Amplitude Upper vertical stretch Lower vertical upsetting Turn right Trun left Left horizontal upsetting Right horizontal stretch Turn left Turn right Position Upper move up L...

Страница 7: ...se You can Stop the start e g in case if some one forgot to waer goggles Reset individual settings With Reset you can get back to the origi nal settings With Reset circle all individual settings will...

Страница 8: ...fifteen seconds The timer will count down to zero and the administe red amount of energy increases A long beep will be announced once the therapy time is reached The current treat ment can be aborted...

Страница 9: ...erapeutic effect If you want a more point orientated therapy slow down the speed this will bring more heat to the body in case you want less heat simply reduce the speed The supplied energy remains th...

Страница 10: ...device Do not use a solvent If you work with an applicator sterilise the applicator after each use in order to avoid transmitting infection to the patient Calibration and safety check Your Satellite d...

Страница 11: ...hPa Laser Diodes Quantity Wavelength Power Laser typ NOHD Beam diver gence 1x red 638 nm max 150 mW Continuous beam CW 10 m 3 mrad 1x infra red 810 nm max 500 mW Continuous beam CW 10 m 3 mrad LED Dio...

Страница 12: ...be performed by the retailer otherwise the guarantee expires Any alterations or interventions on the device by an unauthorized third party void the guarantee The manufacturer guarantees replacement pa...

Страница 13: ...stributor REIMERS JANSSEN GmbH Photomedicine Laser Therapy Fabrikstr 22 79183 Waldkirch Germany Tel 49 7681 4934149 Fax 49 7681 4934149 service rj laser com www rj laser com Quality Management ISO 134...

Отзывы: