background image

 

           

 

   

 
 

Warning………………………………………………. 

    Parts Name…………………………………………… 

    Installation……………………………………………. 

    Installation Instruction………………………………. 

    Caution………………………………………………... 

    Operation Instruction………………………………… 

    Maintenance & Cleaning…………………………….. 

    Trouble Shooting……………………………………… 

    Warranty & Wiring Diagram………………………. 

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

           

   

  COOKER HOOD 

 

 

INSTRUCTION MANUAL 

 

NAME 

  PAGE 

Products and accessory …..………1   

Dimensions………………………...2 

Caution…………………………….4

 

Operating Instruction……….…...5 

Maintenance 

  Cleaning…........6   

Trouble Shooting…………………7 

Wiring Diagram………………..…8 

Specification………………………9 

Model:RH-9021A 

Instruction…………………….…...3

 

Summary of Contents for RH-9021A

Page 1: ...tion Maintenance Cleaning Trouble Shooting Warranty Wiring Diagram COOKER HOOD INSTRUCTION MANUAL NAME PAGE Products and accessory 1 Dimensions 2 Caution 4 Operating Instruction 5 Maintenance Cleaning 6 Trouble Shooting 7 Wiring Diagram 8 Specification 9 Model RH 9021A Instruction 3 ...

Page 2: ...S Aluminium pipe 1 PCS For Fixing Assy screw 2 PCS For Aluminium Tube screw 3 PCS 1 Electric Box Cover Power cable Tube top cover Fan Blade Left Ventilator seal Glass Body Oil Cup Body Mesh Filter Capacitor Control Board Fan Blade Right Motor Ventilator Body Oil Plate Main Tube Unit LED Light Switch cover Press Button Control Panel Switch Base Electric Box ...

Page 3: ...Dimensions 2 MODEL A B C RH 9021A 210mm 896mm 510mm 153 6 C B Hook Location A 210 896 510 896mm 510mm 60mm min 460 max 900 mm Excluding with height of main unit 300mm 298mm ...

Page 4: ...it horizontal level 75 90CM 896mm 510mm 60mm min 460 max 900 mm Excluding with height of main unit 300mm 298mm Aluminium tube bracket install Install aluminium tube bracket according to the kitchen cabinet design Find the suitable location and install it on the wall fig 1 Fig 1 Aluminium tube install 1 Adjust aluminium tube height according to the kitchen cabinet design Insert the aluminium tube i...

Page 5: ...efore uninstall 1 Please keep a minimum 75 90 cm distance between cooker hood and cooker Different types of cooker might require a bigger space fig2 fig2 2 Do not flame under the cooker hood fig3 fig3 3 Adjust the aluminium tube to make sure all the exhaust air has blown out successful 4 There shall be adequate ventilation of the room when the cooker hood is used at the same time as appliances bur...

Page 6: ...tton to turn on middle speed ventilation and middle speed indicator light will be on Push again will turn to low speed delay function low speed indicator light will be blink and shut down automatically after 90 seconds 3 Push low speed button to turn on low speed ventilation and low speed indicator light will be on Push again will turn to low speed delay function and low speed indicator light will...

Page 7: ...ray water directly on the cooker hood to avoid electric shock or damage to it 6 Use mild detergent to clean the impeller Pull out the oil cup and wash it 7 Always wash or change the filter and clean up the cooker hood regularly 8 Minimum clean up the cooker hood once a week 9 Kindly follow this cleaning instruction to avoid dangerous 10 If the supply cord is damaged it must be replaced by the manu...

Page 8: ...mpeller deformed 3 Weak Suction Far distance between cooker hood and glass hob Check if aluminum pipe is too long or curve Change to 7 inch diameter if necessary Check if there is excess ventilation Check the aluminum pipe make sure exhaust air and flame blow out smoothly Window should be closed while operating cooker hood 4 Oil Plate Broke Please get the original parts from any authorize dealers ...

Page 9: ...Wiring Diagram RH 9021A 8 GRAY BLUE WHITE ELECTRIC BOARD LAMP LAMP BLACK POWER CONDENSER MOTOR YELLOW WHITE BLUE GRAY WHITE YELLOW BROWN WHITE BROWN WHITE BLACK BLACK BLACK BLUE FUSE Control Board ...

Page 10: ...0 960mm Height From button of main unit OUTLET DIA 153mm FAN SIZE 14CMx2 MOTOR S 1 INSULATION E VOLTTAGE FREQUENCY 240V 50Hz AMP 1 5A LIGHT 2W SPEED Ⅰ Ⅱ Ⅲ MOTOR SPEED 1200rpm 1800rpm 2400rpm CONSUMPTION POWER 180W 220W 270W AIR FLOW MAX 600m hr 900m hr 1200m hr C O O TAIWAN 9 ...

Reviews: