background image

1

Continuum

HV SERIES 1

Summary of Contents for Continuum CONHV 250 I

Page 1: ...1 Continuum HV SERIES 1 ...

Page 2: ...s be installed to the applicable codes and suggested siting positions can be found on the next page Temperature pressure relief valves The appliance is fitted with temperature and pressure relief valves that are rated for the Rinnai continuum external model only For remote usage the pressure and temperature relief valves should be sized and fitted according to the heat input of the Infinity water ...

Page 3: ...minimum below eaves balconies or other projections D 1500mm minimum vertically below an operable window non mechanical air inlet or any other opening into a building E 500mm minimum from a return or external corner F 150mm minimum from a drain or soil pipe G 500mm minimum from an electricity meter or fuse box H 1000mm minimum from a gas meter 1500mm from LPG gas bottles I 500mm minimum from a neig...

Page 4: ... Cylinder recovery time at 50 Degree rise 21 28 Pump supplied Yes Thermostat supplied Yes Thermostat range 60 85 degrees Water flow rates 1st Hour Continuous 1st Hour Continuous Water flow at 40 degree rise 1125 900 1197 900 Water flow at 45 degree rise 1025 800 1097 800 Water flow at 50 degree rise 945 720 1017 720 Water flow at 55 degree rise 880 655 952 655 Water flow at 60 degree rise 825 600 ...

Page 5: ...ndary Return Hot Water Outlet Rinnai Continuum Temperature Pressure Relief valve Secondary Flow Cold Water Inlet Infinity Flow Infinity Water Heater Gas Connection Pump Cylinder Thermostat Wiring Junction Box ...

Page 6: ...6 560 mm 250L 610 mm 330L 900 mm 900 mm 1405 mm 1510 mm 180 mm 270 mm 865 mm 180 mm 1715 mm 330 1540 mm 250 ...

Page 7: ...7 Pump L N E L N E L L N E Thermostat Pump Infinity Junction box Wiring diagram for Rinnai Schematic diagram for Rinnai Continuum N E N E Infinity Thermostat L Pump L ...

Page 8: ...econdary Return Hot Water Outlet Internal Rinnai Continuum Temperature Pressure Relief valve Secondary Flow Cold Water Inlet Cylinder Thermostat Flow from external Infinity Return pipe to external Infinity ...

Page 9: ...instructions Warranty Exclusions The warranty does not cover damages caused by excess water pressure or any water damages caused by water leaks in the installation Warranty covers only the direct replacement of the faulty parts and excludes any part of the installation not supplied by Rinnai New Zealand Water Quality Water that is outside the maximum recommended limits will void the warranty If yo...

Reviews: