WIRELESS FLOOD DETECTOR

«

CN-Flood-Mini

»

 

1 Product Overview

1.1 Wireless flood detector «CN-Flood-Mini» (hereinafter, the 

Detector) is intended for detecting leaks of water from water-supply 
pipelines or heating facilities and generating an alarm message via 
a two-way communication by the «CN-Contact-R» protocol. The 
Detector is intended to operate as a component of any control 
panel (hereinafter, CP) supporting the wireless exchange protocol 

 

«CN-Contact-R».

1.2 Water leaks control is ensured by measurement of an external 

resistance between sensor terminals of the Detector.

1.3 Radio signals are exchanged within the 433.05 to 434.79 MHz 

frequency range. The transmitter output power does not exceed 

 

10 mW.

1.4 Two operating frequencies: main and reserve are used for the 

wireless data exchange. The Detector switches over reserve operating 
frequency automatically. 

1.5 Radio exchange sessions are initiated by the Detector at a 

preset frequency. The frequency settings are 10, 15, 30 sec, 1, 5,  
10 min, chosen in the process of the binding procedure. The Detector 
transmits alarm messages to the CP immediately.

1.6 The Detector power supply is provided by power supply batteries 

placed inside it’s case: the main one and the backup one (CR2450).

1.7 The Detector state is displayed by two-color LED indicator.
1.8 The Detector generates and transmits the following messages 

via a two-way communication:

- «Norm» – if the external resistance between sensor terminals value 

is 200 k

Ω

 or more;

- «Alarm» – if the external resistance between sensor terminals 

value is 100 k

Ω

 or less;

- «Tamper» – in the event of case tampering or the Detector removal 

from the mounting surface;

- «Main Power Supply Low Battery» – under the main power supply 

battery voltage drop below 2.8

-0.4

 V;

- «Backup Power Supply Low Battery» – under the backup power 

supply battery voltage drop below 2.8

-0.4

 V.

1.9 The Detector is designed to operate continuously, around the 

clock. 

2 Features

Table 1

Parameter

Value

Operating temperature, °C

minus 20 … +50

Permissible relative humidity at +25 °С without 

moisture condensation up to, %

95 

Ambient class

Boreal Climate * 

IP rating

IP65

Dimensions, maximum, mm

65 x 55 x 20 

Weight, maximum, kg

0,05 

Average service life, not less, years

Operation time upon normal climate conditions* and 

preset wireless signal exchange rate 30 sec and 

more, months:

- from the main battery, not less:

- from the reserve battery, not less:

36 

* background temperature 15 – 35 °C, relative air humidity 

 

25 – 75 %, air pressure 86 – 106 kPa.

3 Scope of Delivery

Each Detector unit package contains the items listed in Table 2.
Table 2

Name

QNT.

Wireless flood detector «CN-Flood-Mini»
Screw 3-3х30.016 
CR2450 lithium power supply battery
Wireless flood detector «CN-Flood-Mini». Installation Guide 

1 pc.
1 pc.

2 pcs.

1 copy

4 The Detector Design

The Detector comprises the base with the openable mounting 

 

hole (7) printed circuit board (1) (PCB) installed on the cover. The PCB 
comprises the following elements: main power supply battery holder 
plate (2), «RESET» contacts (3), backup power supply battery holder 
plate (4), sensor terminals (5), tamper contacts (6).

Figure 1 – The Detector Design 

5 Indication

The Detector has the following indication modes:
- «Binding» procedure LED indication (procedure of logging in the CP);
- «Identification» indication mode – lights up by the relevant command 

from CP and remains active during 15 min or until the case is opened;

- LED indication of the Detector state is activated after the Detector 

cover is closed and remains active during 15 min under conditions:

- other LED indication types absence; 
- alarm «Tamper» message is not generated during this time;
- absence of command from the CP disabling the Detector state 

indication. 

LED indicator modes are listed in the Table 3.
Table 3

The Detector State

LED Indication

Note

Binding procedure 

finished

LED lighting red for  

2 – 3 sec

«Binding» mode

LED blinking green

The Detector logging in 

the CP

«Identification»

Alternate LED red and 

green alternate  blinking

on command from the 

CP

«Alarm»

Single-shot LED lights up 

red for 4 sec

State indication is on 

and «Identification» 

indication is off

Radio communication 

quality appraising

See sect. «Radio communication quality appraising»

«Normal»

Indication is off

6 Binding with the CP

«Binding» mode is used for logging the Detector in the CP and service 

information exchange.

6.1 Prepare the CP in accordance with CP reference guide.
6.2 Initially install the backup power supply battery to the holder  

plate (4) on the PCB, thereupon install the main power supply battery to 
the holder plate (2)  (or remove the insulators with installed batteries). 

6.3 Periodical LED indicator blinking green is evidence of binding 

process.

6.4 In case of mentioned above LED indication absence, short-circuit 

«RESET» terminals for 2 – 3 sec. 

6.5 The time limit for the binding process of the Detector is 100 sec. 

To restart the binding procedure, short-circuit «RESET» terminals for 
2 – 3 sec. 

7 Communication Quality Appraising

7.1 To apprise the radio communication quality it is necessary to 

act as follows:

- place initially backup and then main power supply batteries to the 

correspondent holder plates (or remove the insulators with installed 
batteries);

- set the Detector on the assumed place of installation;
- push and then release case tamper.
7.2 After case tamper releasing the Detector generates case 

tamper alarm message, transmits it via radio communication channel 
and represents communication quality with CP by LED indication in 
accordance with the Table 4.

Table 4

LED Indication

Radio 

communication 

quality appraisal

Recommendations

Color

Mode

Green

Three blinks

Excellent

Install the Detector on this 

place

Green

Two blinks

Good

Green

One blink

Communication 

established

Choose another place 

for installation or use a 

repeater*)

Red

Four blinks

No 

communication

*) –

 

CN-Repeater

Installation Guide

а) Base

b) PCB installed on the cover

1

7

2

3

4

6

5

5

RESET

the main

the backup