background image

DRIVER MAINTENANCE KIT 

 

R175RNF Roofing Coil Nailer 

THIS KIT INCLUDES:

Cylinder Cap Seal (15) 

Bumper (24)

 Fixed Pin (75) 

Piston Ring (17)

Nail Straightener Spring (67) 

O-Rings (76)

 Driver Unit (18) 

Nail Straightener (74)

 Cushion  (120) 

Grease

Driver Maintenance Kit Instruction Sheet

Tools needed (but not included): 2 flat head screwdrivers and 4 mm hex key

DRIVER MAINTENANCE

See Figures 1 - 2.

  1.  Disconnect the tool from the air supply and remove any fasteners that 

remain in the tool.

 2. Using a 4 mm hex key, remove the four 

screws (5)

 from the  

cap (8)

 of the tool.

  3.  Remove the two 

brackets (6)

 and 

cap (8).

 Set aside.

  4.  Remove the 

cylinder cap seal (15)

.

  5.  Remove the 

press ring (16) 

from the top of the 

cylinder (19)

. Set aside.

  6.  With two flat head screwdrivers, gently pry the 

cylinder (19) 

from the 

tool body as shown in Figure 1. 

  7.  Remove old 

driver unit (18

) from the 

cylinder (19)

.

 8. Remove 

bumper (24)

 and replace with new 

bumper (24)

.

  9.  Clean all parts with a dry, clean cloth.
 10.  Install the new 

piston ring (17)

 on the new 

driver unit (18)

.

 11.  Reinsert  the 

driver unit (18) 

and 

cylinder (19

) into the tool body. 

Be sure the driver shaft is inserted in the proper direction and the  

cylinder (19) 

is completely seated in the tool body.

12.   Reinstall 

press ring (16) 

on top of 

cylinder (19)

 with flat surface of 

ring facing upwards.

 13.  Install  new 

cylinder cap seal (15)

.

 14.  Reinstall and secure the

 cap (8)

brackets (6)

 and 

screws (5

).

   NOTE:

  To properly seat cap, tighten the screws at alternate corners 

a few turns at a time until all screws are secure.

DANGER:

Do not use oxygen, combustible gases, or bottled gases as a power source for this tool. The tool will explode and 

cause death or serious injury.

WARNING: 

To reduce the risk of injury, the user must read and understand the operator’s manual before using this product. If the 

operator’s manual which originally accompanied this tool is missing, visit us at www.RIDGID.com or call 1-866-539-1710.

WARNING:

Disconnect the tool from the air supply before performing maintenance on this tool. Failure to do so could result in 

serious personal injury.

WARNING:

The operation of any power tool can result in foreign objects being thrown into your eyes, which can result in severe 

eye damage. Before beginning power tool operation, always wear safety goggles or safety glasses with side shields, 

or a full face shield when needed. We recommend Wide Vision Safety Mask for use over eyeglasses or standard safety 

glasses with side shields. Always use eye protection which is marked to comply with ANSI Z87.1.

Fig. 1

24

19

17

18

15

5

6

8

6

16

Fig. 2

19

Summary of Contents for R175RNF

Page 1: ... seated in the tool body 12 Reinstall press ring 16 on top of cylinder 19 with flat surface of ring facing upwards 13 Install new cylinder cap seal 15 14 Reinstall and secure the cap 8 brackets 6 and screws 5 NOTE To properly seat cap tighten the screws at alternate corners a few turns at a time until all screws are secure DANGER Do not use oxygen combustible gases or bottled gases as a power sour...

Page 2: ... straightener 74 nail straightener spring 67 and cushion 120 4 Install new cushion 120 so that its flat side rests inside recessed hole in the nailer 5 Install new nail straightener spring 67 over tapered end of cushion 120 6 Install new nail straightener 74 making sure the nail straightener spring 67 rests inside recessed hole on the nail straightener 74 7 Install new fixed pin 75 8 Apply a light...

Page 3: ...ustré et que le cylindre est complètement inséré dans le corps de l outil 12 Réinstaller le segment de piston 16 sur le cylindre 19 en plaçant le côté plat vers le haut 13 Installer le nouveau joint du couvercle de cylindre 15 14 Réinstaller et fixer le couvercle 8 les supports 6 et les vis 5 NOTE Pour positionner correctement le capuchon serrer les vis de chaque coin de quelques tours à tour de r...

Page 4: ...eau ressort de redressement de clou 67 sur l extrémité conique du coussinet 120 6 Installer le nouveau redresseur de clou 74 s assurant que le ressort de redressement de clou 67 reste à l intérieur du trou fraisé du redresseur de clou 74 7 Installer la nouveau axe fixé 75 8 Appliquer une légère couche de graisse sur les nouveaux joints toriques 76 en mettre en place un de chaque côté de l axe fixé...

Page 5: ...el cilindro 19 se inserte completamente en el armazón de la herramienta 12 Vuelva a instalar el anillo de presión 16 en el cilindro 19 con el lado plano hacia arriba 13 Coloque el nuevo sello de la tapa del cilindro 15 14 Vuelva a instalar y fijar la tapa 8 soportes 6 y los tornillos 5 NOTA Para asentar correctamente la tapa apriete con unas pocas vueltas a la vez los tornillos de esquinas alterna...

Page 6: ...clavos 67 sobre el extremo cónico del cojín 120 6 Instale el enderezador de clavos 74 nuevo asegurándose de que el resorte para enderezador de clavos 67 quede dentro del agujero retraído del enderezador de clavos 74 7 Instale el pasador fijo 75 nuevo 8 Aplique una capa delgada de grasa a las nuevas juntas tóricas 76 instale una en cada lado del pasador fijo 75 75 67 74 76 76 120 Fig 3 ONE WORLD TE...

Reviews: