Operating Instructions 

REOTRON SMP 

Power Supply

 

ELEKTRONIK

 

Electronic Power Controller 

REO (UK) LTD 

Units 2-4 Callow Hill Road, Craven Arms Business Park, 
Craven Arms, Shropshire SY7 8NT 
Tel. 01588 673411 
Fax 01588 672718 
www.reo.co.uk 
eMail: [email protected]

 

 

Summary of Contents for REOTRON SMP

Page 1: ...Instructions REOTRON SMP Power Supply ELEKTRONIK Electronic Power Controller REO UK LTD Units 2 4 Callow Hill Road Craven Arms Business Park Craven Arms Shropshire SY7 8NT Tel 01588 673411 Fax 01588 672718 www reo co uk eMail sales reo co uk ...

Page 2: ...ns are provided for the personal safety of operators and also for the protection of the described product and connected equipment Warning Hazardous Voltage Failure to observe can kill cause serious injury or damage Isolate from mains before installation or dismantling work as well as for fuse changes or post installation modifications Observe the prescribed accident prevention and safety rules for...

Page 3: ...ntrols 5 6 1 Description of controls 5 6 2 How to use the controls 5 6 3 Setting procedure 5 6 4 Displays 6 6 4 1 Operating modes 6 6 4 2 Fault displays 6 6 5 Parameter settings and ranges 7 7 0 Settings 8 7 1 Configure 8 7 2 Minimum and maximum values 8 7 4 Reset error messages 9 7 5 Save user settings 9 7 6 Recall saved settings 9 7 7 Hide display menus 9 8 0 Connections 10 9 0 Dimensions 11 10 ...

Page 4: ...r 0 20 mA Set point 2 Current set point 0 10 V DC 0 4 20 mA or Potentiometer 10 k 5 7 8 10V 6 for 0 20 mA Enable Contact or 24 V DC signal voltage 31 32 33 24V Enable 24 V DC signal on enable input 24V ON External contact on terminals 32 and 33 or external 24 V signal on terminals 31 and 32 Voltage regulation Set point 1 Set point 2 Current at 10V Ref Link between terminals 7 and 8 Connect voltage...

Page 5: ...nection the units can be linked together In all cases the set points are connected in parallel When a 0 4 20 mA control signal is used a 500 ohm resistor must be connected across terminals 1 3 and 5 7 respectively The current source must be capable of delivering at least 10V 5 0 Technical Data Unit type REOTRON SMP 24 100 REOTRON SMP 24 200 REOTRON SMP 15 220 Input voltage V 3 x 400 10 Input frequ...

Page 6: ...unauthorised changes to the settings these are protected under operating menus A user code must be entered to open the menus There are different menus for the various functions New values are saved upon leaving the programming mode or when a key is not pressed for 100 seconds 6 3 Setting procedure Every adjustment is made by firstly pressing the programming key P The following flow diagram should ...

Page 7: ... leaving the programming mode or if no keys are pressed for 30 seconds delay then the settings will be saved 6 4 1 Operating modes Normal operation No unit enable Unit stopped by using the O Key Illuminated left hand decimal point in the display Current regulation maximum current for the unit or the selected current limit has been reached 6 4 2 Fault displays Over temperature Input voltage too hig...

Page 8: ...0 020 Maximum current 50 100 i 100 020 Maximum power 50 100 o 100 020 Soft start 0 60 sec 0 1 020 Soft stop 0 60 sec 0 1 020 Internal set point voltage display 0 100 U 0 002 Internal set point current display 0 100 I 0 002 Internal set point power display 0 100 P 0 002 Error reset Clr Er 009 Save settings PUSH 143 Return to factory settings FAC 210 Return to user settings US PA 210 Disable program...

Page 9: ...eys 4 20 0 External Set point 0 20 mA 0 10V 4 20 I External Set point 4 20 mA E F P 0 Voltage Current regulation E F P I Power regulation Power set point 0 Enable I Enable invert Code 003 Run mode Min ouptput voltage without external set point Min output current without external set point Output voltage limit Umax Start ramp time sec Run mode Output current limit Imax Stop ramp time sec P P P P P ...

Page 10: ...s 7 6 Recall saved settings 7 7 Hide display menus P P Code 009 Error reset Error and all set points reset Check set point P P P P P Code 143 Save new parameters Run mode P P P P P P Code 210 Return to factory settings Return to user settings Run mode P P P P Code 117 Hd C 1 Hide menus Run mode ...

Page 11: ...uctions REOTRON SMP 10 ELEKTRONIK 8 0 Connections Control terminals Power terminals A2 A1 0 10 V 0 4 20 mA Set point voltage Set point current Pot 10 K 41 42 43 1 2 3 4 5 6 7 8 10V 10V Internal relais Enable 31 32 33 ...

Page 12: ...ctions REOTRON SMP 11 ELEKTRONIK 9 0 Dimensions 433 177 428 F1 F2 F3 L1 L2 L3 N PE INPUT 3x 400V 50 60Hz A2 A1 REOTRON SMP 24 200 1 2 3 4 5 6 7 8 9 10 L1 L2 L3 N PE F I 0 P A B Dims A B SMP 100 405 365 SMO 200 505 465 ...

Page 13: ...Operating Instructions REOTRON SMP 12 ELEKTRONIK 10 0 Connection example Parallel connection Common terminals Load Load Output terminals Output terminals ...