background image

Doc. PS1292

Zone Selection Panel

®

REDBACK

A 2080 PA Speaker Zone Selection Panel

Proudly Assembled in Australia

O

PERATING

 I

NSTRUCTIONS

Distributed by Altronic Distributors Pty. Ltd. Perth. Western Australia.

The 

REDBACK

A 2080 Public Address Speaker Zone

Selection Panel allows you to select either;

1.

One speaker zone only.

2.

A combination of speaker zones.

3.

All speaker zones

This allows great flexibility when paging.

By connecting together one or more Zone Selection
Panels in a ‘Daisy Chain’ fashion, any number of speaker
zones are available (eg Three Zone Selection Panels will
give you a total of 30 speaker zones).

I

NSTALLATION

We recommend the Zone Selection Panels for use only
with 70 Volt or 100 Volt line amplifiers with a maximum
load of 50 watts per zone (at 100V).  Connecting these
units to a 4

or 8

amplifier system may damage your

amplifier.

We have supplied an identification strip (with double
sided tape) which can be attached to the front panel of
the unit.  The identification strip can be engraved to help
identify your speaker zones.

PA Amplifier

100V

Output

Amp Input

Zone Selector

All Call

Zone 1 to 10 Outputs

to Speakers

Speakers

Max Load

50W Per

Zone

Connecting one zone

selection panel.

PA Amplifier

100V

Output

}

To Next Slave
Zone Selector

Amp Input

Master Zone

Selector

All Call

Zone 1 to 10 Outputs

to Speakers

Speakers

Max Load

50W Per

Zone

Amp Input

All Call

Zone 1 to 10 Outputs

to Speakers

Slave Zone

Selector 1

Speakers

Max Load

50W Per

Zone

Connecting two
or  more zone
selection panels.

Reviews: