background image

Pure Sine Wave Inverters

R-12-350S/R-24-350S

R-12-700S/R-24-700S

R-12-1000S/R-24-1000S
R-12-1500S/R-24-1500S

R-12-2000S/R-24-2000S
R-12-3000S/R-24-3000S

Summary of Contents for R-12-1000S

Page 1: ...Pure Sine Wave Inverters R 12 350S R 24 350S R 12 700S R 24 700S R 12 1000S R 24 1000S R 12 1500S R 24 1500S R 12 2000S R 24 2000S R 12 3000S R 24 3000S ...

Page 2: ...o clearance compartment Overheating may result To avoid a risk of fire and or electronic shock make sure that existing wiring is in good condition and not undersized Do not operate the inverter with damaged or substandard wiring Some components in the inverter can cause arcs and sparks To prevent fire or explosion do not put batteries flammable materials or anything that should be ignition protect...

Page 3: ...de Settings 700W 3000W 08 7 AC Frequency Setting All Models 09 2 Rear Panel Operations 09 1 Rear Panel View 09 2 On Off Remote Switch 350W Only 10 3 Remote Port 700W 3000W 10 4 Ventilation Fan 10 5 DC Input Terminal All Models 11 6 Chassis Ground 11 3 INSTALLATION Guide 12 1 Mounting 12 2 DC Wiring Connections 700W 3000W 12 1 DC Cable Size 13 3 Wiring Diagrams 14 4 DC Cable Connection 700W 3000W 1...

Page 4: ...rrent Draw 0 25A 0 25A 0 28A 0 60A 0 55A Input Voltage Regulation 10 5V 15 0V Input Level Indicator N A Red Orange Green LEDs Load Level Indicator N A Red Orange Green LEDs Failure Indicator Red LED Protection Overload Short Circuit Reverse Polarity Fuse Over Under Voltage Over Temp Remote Control Unit Hardwire CR 6 12 CR 8 Safety Certificate EN60950 1 EMC EN55022 1997 EN55024 1997 EN61000 3 2 199...

Page 5: ...rrent Draw 0 15A 0 15A 0 15A 0 25A 0 35A Input Voltage Regulation 21 0 30 0V Input Level Indicator N A Red Orange Green LEDs Load Level Indicator N A Red Orange Green LEDs Failure Indicator Red LED Protection Overload Short Circuit Reverse Polarity Fuse Over Under Voltage Over Temp Remote Control Unit Hardwire CR 6 24 CR 8 Safety Certificate EN60950 1 EMC EN55022 1997 EN55024 1997 EN61000 3 2 1998...

Page 6: ... 3000S A 180mm 270mm 340mm 370mm 370mm 400mm B 125mm 150mm 150mm 160mm 180mm 180mm C 60mm 70mm 85mm 85mm 165mm 165mm D 145mm 175mm 180mm 190mm 210mm 210mm E 132mm 195mm 195mm 195mm 245mm 245mm F 135mm 160mm 165mm 175mm 195mm 195mm G 6mm 8mm 8mm 8mm 9mm 9mm A B C D F E G ...

Page 7: ...talled and used properly Please read this instruction manual before you install and operate your inverter 2 1 Front Panel Operation 2 1 1 Front Panel View 350W 1000W 1500W 700W 2000W 3000W On Off Rem Switch AC Output Input Level Load Level Status Frequency Power Saving AC Output Power Status Frequency On Off Rem Switch Input Level Load Level Status Frequency Power Saving AC Output ...

Page 8: ... Level using this sequence of flashes and colours on the LED LED Status 12V Inverters 24V Inverters RED Slow Blink 10 3 10 6 20 5 21 2 RED 10 6 11 0 21 2 21 8 ORANGE 11 0 12 1 21 8 24 1 GREEN 12 1 14 2 24 1 28 6 ORANGE Blink 14 2 15 0 28 6 30 0 RED Blink 15 0 30 3 2 1 4 Load Level Display 700W 3000W The Load Level LED Display is designed to advise the user of the currently supplied AC Wattage The ...

Page 9: ...etails on status indication Note Power Saving Mode not available for 350W model 2 1 6 Power Saving Mode Settings 700W 3000W Power saving mode will trigger when the AC Loaded Wattage Power Consumption falls below the set threshold The threshold can be set using S1 S2 and S3 on the DIP switch Panel in the sequences shown on this table 700W 1000W 1500W 2000W 3000W S1 S2 S3 DISABLE DISABLE DISABLE Off...

Page 10: ... DIP switch is the AC Frequency setting Frequency Switch 50Hz Off 60Hz On 2 2 Rear Panel Operations 2 2 1 Rear Panel View 350W 1000W 1500W 700W 2000W 3000W Chassis Ground Remote Port On Off Rem Switch DC Input Terminal Ventilation Fan DC Input Terminal Ventilation Fan Chassis Ground Remote Port DC Input Terminal Ventilation Fan Chassis Ground Remote Port ...

Page 11: ...h Examples 2 2 3 Remote Port 700W 3000W Redarc 700W to 3000W inverters are compatible with the CR 6 CR 8 remote controls Before using the remote unit you need to ensure the main switch is in the REMOTE position and the input voltage of the power inverter is the same as the remote unit 2 2 4 Ventilation Fan The fan is load controlled and will engage when the AC Power Consumption reaches a certain l...

Page 12: ...The Inverter is protected against reverse polarity connection using an internal fuse Model DC Input Voltage Minimum Maximum 12V 10 5 15 0 24V 21 0 30 0 2 2 6 Chassis Ground The Chassis Ground terminal should be connected to the vehicle Chassis using 7 5mm cable as a minimum WARNING Operating the inverter without a proper ground connection may cause an electrical hazard 11 ...

Page 13: ...atteries 8 Use the recommended wire lengths and sizes see section 3 2 9 Do not mount the Inverter where it will be exposed to the gasses produced by the battery These gasses are very corrosive and prolonged exposure will damage the Inverter WARNING SHOCK HAZARD Before proceeding further carefully check that the Inverter is NOT connected to any batteries and that all wiring is disconnected from any...

Page 14: ...mps A 5 10 20 30 40 50 60 70 80 90 100 Distance m 1 1 2 3 5 5 5 5 7 5 10 10 16 16 2 1 2 3 5 5 5 7 5 10 10 16 16 16 3 1 2 5 5 5 7 5 7 5 10 16 16 17 25 4 1 2 5 5 7 5 7 5 10 10 16 16 25 25 5 1 2 5 5 7 5 10 10 16 16 25 25 25 6 2 2 5 5 7 5 10 10 16 25 25 25 25 7 2 2 5 5 7 5 10 10 16 25 25 23 25 8 2 3 5 7 5 10 10 16 16 25 25 25 25 9 2 3 5 7 5 10 16 16 25 25 25 25 35 10 2 3 5 7 5 10 16 16 25 25 25 35 35 ...

Page 15: ...14 3 INSTALLATION 3 3 Wiring Diagrams Battery 2000W 3000W Models Fuse or Circuit Breaker Fuse or Circuit Breaker Battery 350W Models Battery 700W 1000W 1500W Models Fuse or Circuit Breaker ...

Page 16: ...le Connection 700W 3000W 3 4 1 700W 1500W DC Connection method 3 4 2 2000W 3000W DC Connection method 15 M8 Screw Ring Terminal PVC Wire M8 Nut Spring Washer Washer Ring Terminal PVC Wire Plastic Cover Black Plastic Cover Black ...

Page 17: ...wer switch to the ON position the buzzer will send out Beep sounds at this point The inverter will now perform self diagnosis and the LED indicators will also appear various colors Finally the buzzer will Beep again and the Input Level and Status LED indicators will turn Green in color then the inverter starts to work successfully 2 Set the power switch to the OFF position the inverter will stop a...

Page 18: ... is RED and Blinking Slowly Low input voltage UVP Check input voltage ensure that input is above 12 7V 25 2V on 24V NO AC power output Status LED is RED and Blinking Intermittently Thermal Shutdown OTP Ensure that nothing is blocking the ventilation fan at that the ventilation fan is still operational NO AC power output Status LED is RED and is ON Solid Short circuit or wiring error Overload OLP C...

Page 19: ...ollowing 6 1 details of the alleged defect or fault and the circumstances surrounding the defect or fault 6 2 evidence of the claim including photographs of the Product where the subject of the claim is capable of being photographed 6 3 the serial number of the Product specified on the label affixed to the Product and 6 4 proof of purchase documentation for the Product from an authorised distribut...

Page 20: ...istance please contact Redarc Electronics 23 Brodie Road North Lonsdale SA 08 8322 4848 power redarc com au www redarc com au Copyright 2012 Redarc Electronics Pty Ltd All rights reserved www redarc com au WARPSINV REV1 ...