background image

 

 

 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 

 
 
 
 
 
 

 
 

RAVAS-1 

 

OPERATIONAL MANUAL  

Summary of Contents for RAVAS-1

Page 1: ...RAVAS 1 OPERATIONAL MANUAL ...

Page 2: ...f switch 8 4 5 Zero check before weighing correction 9 4 6 Gross weighing 10 4 7 Totalling 12 4 8 Total and reset 13 5 Changing the batteries 14 We would like to inform you about the fact that this RAVAS product is 100 recyclable on the basis that the parts are processed and disposed off in the right manner More information can be found on our website www ravas com Rev 20160420 Printing typographi...

Page 3: ...f maximum capacity Power Source 2 AA penlight batteries 1 2 1 5Vdc Environment General purpose dry little rain Operating temperature 10 o C to 40 o C 14 o F to 104 o F with 10 to 95 relative humidity 3 Warnings Safety measures When using the hand pallet truck with weight indication please observe carefully the instructions and guidelines contained in this manual Always perform each step in sequenc...

Page 4: ...USER MANUAL RAVAS 1 4 Don t lift too slow smooth Don t lift too fast heavy 2 4 Use of weighing pallet truck 4 1 Use accurate weighing ...

Page 5: ...e height has been reached the reference level stripe will be encircled The refence height is almost reached lift very slowly 1 arrow is ON Lift slowly 2 arrows are ON Lift fast 3 arrows are ON The weight shown is negative M The weight has been stored in the memory LB Display shows weight in pounds to be set by parameter settings menu KG Display shows weight in kilogram standard setting Low bat ind...

Page 6: ...n indicator Add weight to total function 2 Recall subtotal function 1 Zero correction function 2 Zero calibration Reset recalled subtotal function Switch off by pressing both keys ZERO OFF TOTAL ON ZERO TOTAL ON ZERO OFF TOTAL ON Key functions ...

Page 7: ...sensor connection Span calibration data lost Recalibrate the system Calibration point must be higher than previous one and higher than value of 25 Or enterered value calibration point value is equal to 0000 symbol is blinking The battery voltage level is running low and has to be changed See page 14 Flashing M memory is full 99 999 kg cannot be shown by using 5 digits no weights can be accepted to...

Page 8: ...4 4 On Off switch Switching on the indicator Switching off the indicator Start up the indicator Shortly press the ON key Switch off the indicator by keeping both keys simultaneously pressed for 2 seconds The indicator will switch off automatically after 2 minutes if no key press and no motion ...

Page 9: ...y 2 3 4 1 5 Be sure the forks of the hand pallet truck are empty The forks are at the reference height Check the zero value in the display When the deviation is more than 5 kg the zero value can be corrected by pressing the Zero key shortly The indicator will directly go back to the normal weighing mode 6 Lift the forks to the reference height and check the zero value in the display ...

Page 10: ...ift 1 2 3 4 2 3 4 1 5 Start up the indicator Shortly press the ON key When the pallet truck is not on the reference height the digits will be flashing Display shows the actual weight on the forks When the pallet truck is empty this value will be within 40 kg Lower the pallet truck into its lowest fork position In lowest position the 3 arrows up are ON Pick up a load and lift it to the reference he...

Page 11: ...USER MANUAL RAVAS 1 11 250kg 7 When the load has been lifted too high the arrow down is ON The pallet truck must be lowered completely to the ground first to allow a new weighing ...

Page 12: ...7 Totalling Press the TOTAL key to add the weighed load to the total weight 2 3 1 4 5 Start up the indicator Shortly press the ON key The value is stored in the memory The M sign is shown in the display Press the TOTAL key to add the 2 nd weighed load to the total weight The value is stored and added in the memory ...

Page 13: ...ing the ZERO key shortly The system will automatically return to the standard weighing mode The M sign is deactivated again The memory can be recalled by pressing the TOTAL key for 3 seconds In turn the indicator shows the last sequence number and the sub total that is currently stored in the memory ...

Page 14: ... system takes place through 2 AA batteries When used normally the batteries will last for about 1 year When the voltage level of the batteries is running low the low bat symbol will be blinking When the batteries are completely empty the weighing system switches off 2 3 4 1 5 6 ...

Reviews: