IMPORTANT

 

Read and understand instruction booklet before using scanner.

Always test scanner for proper operation before each use.

Owner’s Manual

TM

Body Scanner/Metal Detector

hh_2007356.indd   1

1/29/2007   1:38:41 PM

Summary of Contents for Body Scanner/ Metal Detector

Page 1: ...TANT Read and understand instruction booklet before using scanner Always test scanner for proper operation before each use Owner s Manual TM Body Scanner Metal Detector hh_2007356 indd 1 1 29 2007 1 38 41 PM ...

Page 2: ...r sounds a high pitched tone whenever it detects metal a longer tone for larger objects and a shorter one for smaller objects You can use a rechargeable nickel cadmium battery for power and recharge it in the Body Scanner Its features include Red LED Indicator lights when the Body Scanner detects metal De Sense Button reduces the Body Scanner s sensitivity to metal by about 50 percent so you can s...

Page 3: ...R 6 Installing the Battery 6 Charging a Nickel Cadmium Battery 8 OPERATION 10 Turning the Body Scanner On and Off 10 Testing the Body Scanner 10 Body Scanning 11 Adjusting the Body Scanner s Sensitivity 12 Using an Earphone 13 MAINTENANCE 14 SPECIFICATIONS 15 hh_2007356 indd 3 1 29 2007 1 38 42 PM ...

Page 4: ...4 A LOOK AT YOUR BODY SCANNER Scan Area hh_2007356 indd 4 1 29 2007 1 38 42 PM ...

Page 5: ...5 Visual LED Alert Power Switch De Sense Button Snap On Battery Cover Audio Alert Battery Recharger Earphone Jack Sensitivity Adjust hh_2007356 indd 5 1 29 2007 1 38 42 PM ...

Page 6: ...echargeable nickel cadmium battery you must charge it before operating the security wand See Charging a Nickel Cadmium Battery If your Body Scanner requires continuous use you might consider keeping a spare nickel cadmium battery charged Use only a fresh battery of the required size and type Never leave a dead or weak battery in the Body Scanner If you do not plan to use the Body Scanner for sever...

Page 7: ...ive and negative polarity battery positioning Polarity marks are located inside the battery compartment 1 2 3 4 When the battery starts to get low the Body Scanner makes a chirping sound instead of a smooth steady sound and the indicator blinks on and off rapidly when it detects metal Replace the battery or recharge it if you inserted a rechargeable nickel cadmium battery see Charging a Nickel Cad...

Page 8: ...rity wand s recharger earphone jack The recommended Radio Shack AC adapter meets these requirements Using an AC adapter that does not meet these requirements could damage the security wand or the AC adapter Important Your Body Scanner is capable of using a rechargeable nickel cadmium battery At the end of the battery s useful life it must be recycled or disposed of properly Contact your local coun...

Page 9: ...n the side of the wand Plug the AC adapter s other end into a standard AC outlet Charge the battery for 14 to 16 hours Unplug the AC adapter from the AC outlet first Then unplug it from the charging jack Note Let the nickel cadmium battery fully discharge once in a while before you recharge it 1 2 3 4 5 hh_2007356 indd 9 1 29 2007 1 38 49 PM ...

Page 10: ...nd a shorter one for smaller objects Before using the Body Scanner always test it by turning it on and scanning a small metal object such as a quarter to make sure the tone sounds and the indicator lights Silent Alarm Vibration Mode is a feature exclusive to Model 1500 please note that Model 1000 does not have Silent Alarm Vibration Mode ON OFF Rocker Switch ON OFF is located on the top side of th...

Page 11: ...underneath the arm c Down the full body length to the feet d Up the inner leg from the ankle Note If large amounts of metal reinforcement in the floor cause interference at ankle level push and hold De Sense while scanning the ankles e Back down the inner leg to the opposite ankle f Up the other side of the body and over the arm 4 Scan the front torso including the shoulder area 5 Scan the back to...

Page 12: ...dle until it touches the adjustment control inside 2 Turn the screwdriver slowly until its tip fits in the control s slot 3 Using a test object adjust the control for the desired sensitivity clockwise to increase or counterclockwise to decrease sensitivity Note The further you move the control the greater the change in sensitivity The sensitivity control trimpot is located on the scanner s handle ...

Page 13: ...alarm through the earphones Insert the earphone s plug into the Body Scanner s recharger earphone jack on the bottom of the wand The external sound cuts off automatically The headphone jack is located on the underside of the body scanner directly opposite the ON OFF switch hh_2007356 indd 13 1 29 2007 1 38 56 PM ...

Page 14: ... Temperature extremes can shorten the life of electronic devices and distort or melt plastic parts Keep the Body Scanner away from dust and dirt which can cause premature wear of parts Wipe the Body Scanner with a damp cloth occasionally to keep it looking new Do not use harsh chemicals cleaning solvents or strong detergents to clean the security wand Modifying or tampering with the Body Scanner s...

Page 15: ...Weight 14 oz Dimensions 3 x 15 x 1 Inches HWD Tuning Automatic Alert Audio LED Light Specifications are typical individual units might vary Specifications are subject to change and improvement without notice hh_2007356 indd 15 1 29 2007 1 38 56 PM ...

Page 16: ...lity in all events is limited to the purchase price paid Liability under the aforesaid warranty is limited to replacing or repairing at our option any RANGER Hand Held Body Scanner returned shipping cost prepaid to Ranger Security Detectors Inc Limited 2 Year Warranty 11900 MONTANA AVENUE EL PASO TEXAS 79936 TEL 915 590 4441 RANGER SECURITY DETECTORS Inc hh_2007356 indd 16 1 29 2007 1 38 56 PM ...