background image

S050 S

GEAR DRIVEN SPRINKLER SETTING INSTRUCTIONS

CHANGING A NOZZLE

1

REMOVING THE NOZZLE RETENTION SCREW

Use your K-Key or a small flat blade screwdriver to remove the nozzle

retention screw by turning counter-clockwise to remove and clockwise 

to re-install.

2

PULL UP THE RISER

Insert the K-Key in the keyhole on the top of the nozzle turret and turn 

the key 1/4 turn to insure that the key does not slip out of the keyhole 

when you pull it up. Firmly pull up the entire spring-loaded riser to

access the nozzle socket. Hold the riser assembly up with one hand.

3

REMOVING THE NOZZLE

Insert the end of the K-Key, hook side up, into the tall slot along the right

side of the nozzle and pull up to pop out nozzle.

NOTE:

Do not

put the K-Key or any instrument into the nozzle opening.

4

INSTALLING A NOZZLE

Press the desired nozzle into the nozzle socket. Make sure the nozzle

number is visible and the nozzle “Wing” is up. Then, re-install the

nozzle retention screw.

NOTE:

The nozzle retention screw is also a

break-up screw and used to adjust the distance of the spray.

SETTING THE ARC ADJUSTMENT

1

FINDING THE LEFT START POSITION

Place your finger on the top center of the nozzle turret. Rotate the turret

to the right until it stops and then back to the left until it stops. Notice 

the position of the nozzle arrow. This is the “Left Start” position. The

sprinkler will begin spraying from this position and rotate clockwise until

it reaches the right “Arc Stop”.

2

ORIENTING THE LEFT START POSITION

Insert the K-Key in the keyhole on the top of the nozzle turret and turn

the key 1/4 turn to insure that the key does not slip out of the keyhole

when you pull it up. Being careful not to allow the nozzle turret to turn,

firmly pull up the entire spring-loaded riser. Hold the lower riser assembly

up with one hand. Now turn only the lower riser clockwise or counter-

clockwise until the nozzle arrow is pointing where you want the sprinkler

to begin spraying.

3

CHANGING THE ARC

Insert the K-Key or a small flat blade screwdriver into the Arc Set

Adjustment slot. Turn clockwise to increase the arc or counter-clockwise

to decrease the arc.

NOTE:

The arc set arrow in the center of the nozzle turret rotates

to show the current setting.

NOTE:

The

S050S

is factory preset with a 40° arc setting, and includes a pre-installed #1.5 nozzle.