background image

User Manual 

IoT 4~20mA Signal Data Logger

RN400-T2CS

Keep this document nearby so that it may be referred to when needed.

2021 | Rev. 1

Summary of Contents for RN400-T2CS

Page 1: ...User Manual IoT 4 20mA Signal Data Logger RN400 T2CS Keep this document nearby so that it may be referred to when needed 2021 Rev 1...

Page 2: ...duction 05 Key Features 05 Exterior 06 Accessories 07 Specifications 08 Installation 09 Terminal Block 10 Data Logger Installation 11 Connecting Terminal Block 13 4 20mA Signal Sensor 14 Operation 19...

Page 3: ...rver 35 RS 485 Modbus Communication 35 Tapaculo 365 36 Adding Devices from Your Smartphone 37 Adding Devices from Your Computer 40 Maintenance 43 Cleaning 43 Batteries 43 Firmware Update 44 Customer S...

Page 4: ...r from your system depending on installation conditions Software screenshots may change after software updates Intellectual Property Rights 2021 DEKIST Co Ltd All contents and figures herein are prope...

Page 5: ...ensor Channel 2 External 4 20mA Analog Sensor Channel 3 External 4 20mA Analog Sensor Channel 4 External 4 20mA Analog Sensor Key Features Key features of the RN400 T2PS include S W POWER ON OF F 5BQB...

Page 6: ...List About this Manual Exterior S W POWER ON OFF 2 3 4 1 5 Display Power button Menu button Cable gland Display button Power cables and cables of other devices such as external sensors are connected v...

Page 7: ...Adapter 12 V 500 mA In the event of power failure two C type 1 5 V batteries or one 3 6 V battery must be placed in the Data Logger RADIONODE Data Logger is designed to not operate without a battery...

Page 8: ...Data Logger External Sensor Ch1 4 20mA Analog accuracy 0 8 F S Ch2 4 20mA Analog accuracy 0 8 F S Ch3 4 20mA Analog accuracy 0 8 F S Ch4 4 20mA Analog accuracy 0 8 F S Communication 2 4 GHz IEEE 802 1...

Page 9: ...configure the Data Logger See Configuration on page 24 4 Now that the Data Logger has been installed it must be registered to Tapaculo 365 See Tapaculo 365 on page 36 Depending on your installation c...

Page 10: ...t FPC FFC Connection RS485 Output Battery Holder USB for Calibration DC Power 5 30V OLEDConnection 4 20mA Input Select Battery Type Micro SD card is used to log measurement data See Memory Card for Da...

Page 11: ...nstalling a Data Logger is as follows 1 Loosen the screw on the right side of the front panel and open the front panel S W PO WER ON O FF 2 Loosen the cable gland 3 Route the cables of the device that...

Page 12: ...Order List About this Manual Installation 4 Tighten the gland firmly 5 Cover the front panel and tighten the screws S W PO WER ON O FF 6 There Data Logger is equipped with a magnet at the rear Place...

Page 13: ...ing cables to the terminal block ensure that the flat cable does not get disconnected from the front connector Cable Gland If Data Logger cable gland cannot sufficiently receive all cables install add...

Page 14: ...rminals as shown above No additional resistor connection is required at this time If a transmitter with a separate output signal then connect directly to the same polarity After connecting external se...

Page 15: ...ion Refer to the figure above when you connect to your PC for calibration 4 20mA INPUT 2CH 4 20mA INPUT 3CH 4 20mA INPUT 4CH 4 20mA INPUT 1CH A B RS485 POWER 5 30V Setting Scaler from UA CALIBRATOR 1...

Page 16: ...given calibration software called UA CALIBRATOR With the software user can easily read the values and set the configuration parameters How to set up the scale 1 Select a sensor Each RN400 T2CS can ac...

Page 17: ...urate 4 20mA output device for adjustment Calibration Setting Calibration Setting Description Description Min Max value of sensor range Error Correction show the present error values of the channel Wh...

Page 18: ...this Manual Installation Batteries Insert two C type 1 5 V batteries into the battery holder or one 3 6 V battery into the left hand battery holder Be careful not to connect batteries with opposite p...

Page 19: ...ep mode S W POWER ON OFF Viewing Channel Information To view channel information including measurements on sleep mode press the button Press the button repeatedly to display different status informati...

Page 20: ...o the server number of datasets to transfer in the next cycle WIFI SSID dB S menu WIFI SSID dB S menu xxxxxxxx 50dB xxxxxxxx 50dB Wi Fi network name and signal strength LOCAL TIME S menu LOCAL TIME S...

Page 21: ...r fails datasets accumulate until successful INFO S next P exit INFO S next P exit 2 POWER External DC 2 POWER External DC If no external power is connected or power failure occurs Bat Bat will appear...

Page 22: ...6FA1B3 Data Logger MAC address INFO S next P exit INFO S next P exit 11 SW BUILD 20200720 11 SW BUILD 20200720 Firmware version INFO S next P exit INFO S next P exit 12 MODEL RN400T2PS 12 MODEL RN400T...

Page 23: ...rement date timestamp Mac address value for Channel 1 value for Channel 4 In the temp channel Ch 1 or Ch 2 n a means no external temp sensor is connected In the door channel Ch 3 0 means the door cont...

Page 24: ...tion 1 Select 2 CONFIG MODE AP Select 2 CONFIG MODE AP to enable the virtual router The following will appear in the display SOFTAP _RN400 A1B3 SOFTAP _RN400 A1B3 ACCESS 192 168 1 1 ACCESS 192 168 1 1...

Page 25: ...ormation HTTP Radionode Protocol V2 Order List About this Manual Configuration 3 Open your smartphone s web browser and type 192 168 1 1 192 168 1 1 in the address bar The Settings page wiill appear 4...

Page 26: ...365 Owner Tapaculo 365 account ID Mac ADDRESS Data Logger MAC address Model Name Data Logger model number Firmware version Firmware version OTA Release Version OTA Release Version SDCARD Inserted If a...

Page 27: ...ger to operate Data Logger independently without a server Host Server IP address Port Server port number Checkin URL URL of the server program that processes check in requests Datain URL URL of the se...

Page 28: ...Min Sending 5Min is selected sensor measures every 1 minute and measurement data is sent to the server every 5 minutes or written on a memory card Temperature Scale Select the unit of measurement to u...

Page 29: ...he lower the sensitivity CH info Displays a list of I O channels Target Channel Select the input channel that will trigger the alarm relay and specify the normal range For example if you select CH1 Te...

Page 30: ...loser the signal strength is to 0 dBM the stronger the connection If possible use a Wi Fi network with a signal strength of 70 dBm or higher SSID The selected SSD will appear Security Type Select the...

Page 31: ...vice Information HTTP Radionode Protocol V2 Order List About this Manual Configuration If a static IP address is needed select Static and configure additional settings as follows IP Data Logger IP Add...

Page 32: ...e RADIUS server access to the network is granted To connect to a network that uses enterprise security adhere to the following procedure 1 Copy the RADIUS server certificate to a micro SD card with th...

Page 33: ...n Timezone Select which timezone to use Copy Now See Memory Card Usage Configuration on page 34 Debug Code Enter a command to perform a specific function See the following section for a detailed expla...

Page 34: ...into the Data Logger b On the DISPLAY OTHERS page tap Copy to SD Card Copy Now c Remove the SD card 2 Copy the setup data from the SD card to another Data Logger a Insert the SD card into the Data Log...

Page 35: ...he web page verify that the displayed values match the ones shown Press the button to finish RS 485 Modbus Communication The UA Calibarator program is required to change settings of Modbus RTU communi...

Page 36: ...nes how to add new devices and channels to Tapaculo 365 For more information on Tapaculo 365 see the information provided on the web page below https help radionode365 com article categories https hel...

Page 37: ...R code allows you to easily add devices and channels to your smartphone Scan the QR code with your smartphone Alternatively copy the link address from the QR code image and send it to your smartphone...

Page 38: ...P Radionode Protocol V2 Order List About this Manual Tapaculo 365 2 Enter the i code on the device display If you do not see an i code on the display tap Search by MAC address and enter your MAC addre...

Page 39: ...aintenance Customer Service Information HTTP Radionode Protocol V2 Order List About this Manual Tapaculo 365 4 Enter your device name check the box of the channel that will be used then enter the chan...

Page 40: ...e If you do not see your device in the list you can add it using its i code When RN400 Series first connects to Tapaculo 365 its i code is displayed as follows Enter iCode on TP365 Enter iCode on TP36...

Page 41: ...tup New Data Channel All added device channels will be listed This list also includes channels not associated with external sensors or other devices Adding a channel essentially means selecting a chan...

Page 42: ...Information HTTP Radionode Protocol V2 Order List About this Manual Tapaculo 365 Adding Widgets A widget contains one or several channels You can add a widget to the dashboard by clicking Dashboard th...

Page 43: ...r abrasives Not only do these substances damage the surface of the Data Logger but they may also affect sensor performance Batteries Replace the battery when the battery status on the Tapaculo 365 web...

Page 44: ...re file to a micro SD card to the following path and insert it into Data Logger The file name is the same as the model number img T2PS bin img T2PS bin 2 Insert a micro SD card into the Data Logger 3...

Page 45: ...onditions within one year of the product installation date Limit of Liability Warranty repairs are not provided in the event of Failure caused by unapproved installation methods Failure caused by user...

Page 46: ...frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is li...

Page 47: ...ts The radionode device requests transmission of device information from the server at the start of operation and every six hours thereafter This request is called check in The device requests transmi...

Page 48: ...o This parameter is separated by vertical lines and indicates the nature of each channel tags TEMP RH NTC_TEMP NULL NULL NULL tags TEMP RH NTC_TEMP NULL NULL NULL In this example there are a total of...

Page 49: ...h1 Calibration Value of Channel 1 offset ch2 offset ch2 Calibration Value of Channel 2 sample mode sample mode Measurement and Transfer Intervals If this tag s value is 3 the measurement interval chan...

Page 50: ...542 23 19 12 40 121 96 123 P001 1505910942 23 18 12 52 122 04 123 P001 1505910942 23 18 12 52 122 04 123 mac mac MAC address of the device sig sig Strength of wireless signal bat bat Battery status Th...

Page 51: ...ible External Sensors Temp RH RN400 H2PS PR P1 3 PR P1 15 PR K1 3 PR K1 15 Temp RH Door RN400 H2EX PR P1 3 PR P1 15 PR K1 3 PR K1 15 AP D1 AP W1 Temp RN400 T2PS PR N1 20 PR N1 150 RG20 Temp Door RN400...

Page 52: ...100 PR P1 3 3 m PT100 PR P1 15 15 m Type K Thermocouple TC K PR K1 3 3 m Type K Thermocouple TC K PR K1 15 15 m Type T Thermocouple TC T PR T1 3 3 m Type T Thermocouple TC T PR T1 15 15 m NTC PR N1 20...

Page 53: ...Telephone 1566 4359 Fax 82 31 8039 4400 Email master dekist com A1801 13 Heungdeok 1 ro Giheung gu Yongin si Gyeonggi do Korea 16954 2021 DEKIST Co Ltd...

Reviews: