background image

OPERATING AND INSTALLATION INSTRUCTIONS

QK-FTP40

INFRARED BARRIER

INFRARED BARRIER

DESCRIPTION:

The infrared barrier is made up by a projector and a receiver which are stored in a sealing aluminium enclosure. The lens is horizontally 

.

n

o

i

t

c

e

t

o

r

p

 

6

6

P

I

 

g

n

i

r

u

t

a

e

F

 .

°

0

9

 

o

t

 

e

l

b

a

t

s

u

j

d

a

  

APPLICATIONS:

The infrared barrier system is suitable for the protection of automatic opening systems. It can be used for security or as an opening
 consensus device. Thanks to its sturdy enclosure, it is ideal for industrial use.

MODEL:

 

QK-FTP40 

Max range 40 mt 

TECHNICAL DATA:

Emission:

infrared with GA AS diode

Wavelength :

950  nM

Continuous modulation: 

1.33 KHz

Power requirements: 

12/24 VAC/VDC (depending on jumper insertion)

Absorptions:

110 mA to 24 VAC (tx+rx)

Operating temperature:

-10°C+60°C

Contact: 

NA and NC with double relay in series

Max relay contact power:

1A to 24VAC (resistive load)

Led transmitter: 

Power signal

Led receiver: 

Signal for alignment with transmitter 

Horizontal adjustment:

Through a rotation support with screw block

PACKAGING:
The package includes 

n. 1 Transmitter in a metal container and n. 1 Receiver in a metal container.

INSTALLATION:

The transmitter and the receiver must be attached on to the same geometric axis at the same height from the ground.
When installing multiple units, keep in mind that the two receivers positioned on the same side can receive the beam from the same transmitter,
mounted on the opposite side. To avoid this from happening, it is important to find the proper distance between the transmitters and receivers,
while remembering that the infrared beam has an opening of 15° at 1 meter.

INSTALLATION PROCEDURE:

•  the infrared barrier can be installed on any type of level structure and flat surface 
•   after separating the cover from the support base and removing the electronic circuit to avoid damaging it, attach the base to the wall 
•   run the cables through using the special holes being sure to insert the cable glands for a proper hold
•   proceed with making the connections as shown in the attached figure
•   turn on the projector and the receiver and centre them; their alignment will be confirmed when the led on the receiver turns on 
•  attach the cover onto the base, being sure that the hexagon socket head screws are firmly fixed so that the seals around are perimeter are 

under pressure. 

This equipment must be used and installed in full compliance with the manufacturer's instructions and 
current safety standards. The manufacturer cannot be held liable for eventual damages that may result from improper or unreasonable use. 

The Manufacturer declares that the product is in conformity with EN12453 - EN 954-1

ENGLISH

www.quikoitaly.com

Summary of Contents for QK-FTP40

Page 1: ...s at the same height from the ground When installing multiple units keep in mind that the two receivers positioned on the same side can receive the beam from the same transmitter mounted on the opposite side To avoid this from happening it is important to find the proper distance between the transmitters and receivers while remembering that the infrared beam has an opening of 15 at 1 meter INSTALL...

Page 2: ...rapport au terrain Dans le cas d une installation de plusieurs unités il est important de savoir que deux récepteurs positionnés du même côté peuvent recevoir le faisceau de l émetteur habituel monté sur le côté opposé Pour remédier à ce phénomène il est indispensable de trouver la distance correcte entre les émetteurs et les récepteurs sachant que le faisceau infrarouge a une ouverture de 15 à 1 ...

Page 3: ...etrico ed alla stessa altezza dal terreno In caso di installazione di più unità occorre tener presente che due ricevitori posizionati sullo stesso lato possono ricevere il fascio dal solito trasmittente montato sul lato opposto Per ovviare a questo fenomeno è importante trovare la giusta distanza tra i trasmettitori e ricevitori tenendo conto che il fascio all infrarosso ha un apertura di 15 a mt ...

Page 4: ...tivé 24V Montaggio Installation Montage Foro ø 4 Hole Ø 4 Trou ø 4 Orientamento Orientation Orientation Chiusura contenitore Closing the enclosure Fermeture boitier Dimensioni d ingombro Dimensions Dimensions d encombrement Connessioni Connections Connexions Led Segnalazione Alimentazione Led Power Signal Voyant lumineux de Signalisation Alimentation 1 2 5 3 4 www quikoitaly com ...

Reviews: