Summary of Contents for KPC-1920

Page 1: ...I KPC 1920 User s Manual KPC 1920 19 Widescreen Fanless Panel PC with Intel Celeron M 1 5GHz User s Guide ...

Page 2: ...s of others Quanmax is a registered trademark of Quanmax All trademarks registered trademarks and trade names used in this user s guide are the property of their respective owners All rights reserved This user s guide contains information proprietary to Quanmax Customers may reprint and use this user s guide in other publications Customers may alter this user s guide and publish it only after they...

Page 3: ...ory Compliance Statements 8 Warranty Policy 9 Maintaining Your Computer 10 Chapter 1 Introduction 13 Overview 13 Product Specifications 15 Mechanical Layout 16 Chapter 2 Assembly Disassembly 18 Mounting 18 Desktop Mounting 18 Wi FI Antenna Installation optional VESA 19 Chapter 3 Getting Started 20 Power Connection 20 Operating System and Drivers 21 Chapter 4 Maintenance and Prevention 22 Chapter 5...

Page 4: ... 16 Figure 3 Mechanical Dimensions 17 Figure 4 Mounting hole locations on the KPC 1920 18 Figure 5 Attach the base to the desktop mounting bracket 19 Figure 6 Attach the base to the desktop mounting bracket 19 Figure 7 Installing the antenna for the optional Wi Fi card on the KPC 1920 19 Figure 8 DC power inlet location 20 ...

Page 5: ...n definition 23 Table 4 COM1 RS 232 Serial Port Connector pin definition 23 Table 5 COM2 RS232 422 485 Serial Port Connector pin definition 24 Table 6 Parallel Port Connector pin definition 24 Table 7 VGA Display Connector pin definition 24 Table 8 Fast Ethernet 2 USB 2 0 Connector pin definition 25 Table 9 Audio Jack Connector pin definition 25 ...

Page 6: ...tallation instructions in this user s guide for precautions and procedures If you have any questions please contact Quanmax Post Sales Technical Support WARNING High voltages are present inside the chassis when the unit s power cord is plugged into an electrical outlet Turn off system power turn off the power supply and then disconnect the power cord from its source before removing the chassis cov...

Page 7: ...ystem boards Perform service at an ESD workstation and follow proper ESD procedure to reduce the risk of damage to components Quanmax strongly encourages you to follow proper ESD procedure which can include wrist straps and smocks when servicing equipment You can also take the following steps to prevent damage from electrostatic discharge ESD When unpacking a static sensitive component from its sh...

Page 8: ...mediately 3 Inspect the product for damage If there is damage notify Quanmax customer service immediately Refer to Warranty Policy for the return procedure Regulatory Compliance Statements This section provides the FCC compliance statement for Class A devices FCC Compliance Statement for Class A Devices The product s described in this user s guide has been tested and found to comply with the limit...

Page 9: ... to alteration neglect misuse or abuse if any repairs have been attempted by anyone other than Quanmax or its authorized agent or if the failure is caused by accident acts of God or other causes beyond the control of Quanmax or the manufacturer Neglect misuse and abuse shall include any installation operation or maintenance of the product other than in accordance with the user s guide No agent dea...

Page 10: ...ising out of the performance or use of any product furnished hereunder Quanmax s liability shall in no event exceed the purchase price of the product purchased hereunder The foregoing limitation of liability shall be equally applicable to any service provided by Quanmax or its authorized agent Maintaining Your Computer Cleaning Components Internal fans cool the computer by drawing in air through a...

Page 11: ...nductivity Extreme moisture buildup inside the system can result in electrical shorts which can cause serious damage to the system Buildings in which climate is controlled usually maintain an acceptable level of humidity for system equipment However if a system is located in an unusually humid location a dehumidifier can be used to maintain the humidity within an acceptable range Refer to the Spec...

Page 12: ...e conditioners cannot protect against a complete loss of power Uninterruptible Power Supply Uninterruptible power supply UPS systems offer the most complete protection against variations on power because they use battery power to keep the server running when AC power is lost The battery is charged by the AC power while it is available so when AC power is lost the battery can provide power to the s...

Page 13: ...tive applications in retail and educational environments as an information kiosk POS gaming digital signage and thin client Checklist 1 Take out the KPC 1920 from the carton box check if the unit is properly secure in the plastic bag 2 Check the contents of the carton box Panel PC AC power adapter incl wall socket cord Desktop stand arm base Optional Screw bag Wi Fi antenna optional Features Displ...

Page 14: ... following I O interfaces 2x Fast Ethernet RJ45 on panel 5x Serial Port COM2 supports RS 232 422 485 4x USB 2 0 on panel Mic in Line in Line out on panel PS 2 Keyboard Mouse on panel Parallel Port on panel Power Button Storage The KPC 1920 has a 2 5 Hard Disk and a CompactFlash Type II Expansion The KPC 1920 has a Mini PCI slot Power Supply The KPC 1920 is powered by an external 100V 240V AC power...

Page 15: ...n Line in Line out Reset button LCD Display Display type TFT WXGA widescreen LCD Size Diagonal 19 Brightness 300cd m2 Resolution 1440x900 Network Wireless LAN 802 11b g ON board LAN 2xFast Ethernet controller Intel 82551ER Power Supply Output Rating 80W Input Voltage 100 240V Output Voltage 12V Environmental Specification Temperature Operating 0 40 C 5 80 non condensing Storage 20 60 C 5 80 non co...

Page 16: ...Chapter 1 16 KPC 1920 User s Manual Mechanical Layout Front and Side Panel Figure 1 Mechanical Layout Front and Side I O Panel Figure 2 Mechanical Layout I O Panel ...

Page 17: ...Chapter 1 17 KPC 1920 User s Manual Mechanical Dimensions Figure 3 Mechanical Dimensions ...

Page 18: ...th VESA FDMI 100 standard mounting holes as shown below Use M4x0 7 metric machine screws with the appropriate length for your mounting bracket The available internal clearance for the mounting screws is 8mm Figure 4 Mounting hole locations on the KPC 1920 Desktop Mounting The KPC 1920 comes with a desktop mounting bracket Attach the base to the bracket spine using the single large screw provided a...

Page 19: ...ded and a Phillips screwdriver as shown Figure 6 Attach the base to the desktop mounting bracket Wi FI Antenna Installation optional VESA To install the antenna for the optional Wi Fi card on the KPC 1920 remove the cap covering the antenna mount as indicated below and screw the supplied antenna into the mount Figure 7 Installing the antenna for the optional Wi Fi card on the KPC 1920 Antenna ...

Page 20: ...he power cord In situations where a two slot receptacle is present have it replaced with a properly grounded three prong grounding type receptacle Connect the supplied the AC DC adapter to the system by inserting the DC connector of the adapter into DC power inlet on the I O panel of the system as shown Secure the connector by tightening the knurled screw on the DC connector Figure 8 DC power inle...

Page 21: ...ee prong grounding type receptacle Operating System and Drivers If your product does not come with an operating system pre installed you will need to install an operating system and the necessary drivers to operate it After you have finished assembling your system and connected the appropriate power source power it up using the power supply and install the desired operating system You can download...

Page 22: ...920 system requires minimal maintenance and care to keep it operating correctly Occasionally wipe the system with a soft dry cloth You should only remove persistent dirt by use of a soft slightly damp cloth use only a mild detergent Make sure the ventilation holes are clear of debris ...

Page 23: ...6 pin purple Mini DIN Table 3 PS 2 Keyboard Connector pin definition COM1 COM3 5 RS 232 Serial Port Connector D Sub 9 pin male PIN SIGNAL PIN SIGNAL 1 DCD Data Carrier Detect 6 DSR Data Set Ready 2 RXD Receive Data 7 RTS Request to Send 3 TXD Transmit Data 8 CTS Clear to Send 4 DTR Data Terminal Ready 9 RI Ring Indicator 5 Ground Table 4 COM1 RS 232 Serial Port Connector pin definition ...

Page 24: ...allel Data 0 15 Error 3 PD 1 Parallel Data 1 16 Initialize 4 PD 2 Parallel Data 2 17 Select 5 PD 3 Parallel Data 3 18 Ground 6 PD 4 Parallel Data 4 19 Ground 7 PD 5 Parallel Data 5 20 Ground 8 PD 6 Parallel Data 6 21 Ground 9 PD 7 Parallel Data 7 22 Ground 10 ACK Acknowledge 23 Ground 11 Busy 24 Ground 12 Paper Empty 25 Ground 13 Select Table 6 Parallel Port Connector pin definition VGA Display Co...

Page 25: ... 45 USB type A PIN SIGNAL PIN SIGNAL 1 Transmit output 5 NC 2 Transmit output 6 Receive input 3 Receive input 7 NC 4 NC 8 NC Table 8 Fast Ethernet 2 USB 2 0 Connector pin definition Audio Jack Connector 3 port audio jack connector Table 9 Audio Jack Connector pin definition ...