manualshive.com logo in svg
background image

 1 

 

 

 

 

                         7060-227D 

 

 

 

         February 25, 2016

NOTICE: DO NOT DISCARD THIS MANUAL

O-T L

Tested and 

Listed by

Portland

Oregon USA

OMNI-Test Laboratories, Inc.

C

US

Explorer III Large Wood Stove

Model(s):

EXPLR-III-PBK

EXPLR-III-PDB

EXPLR-III-PFT

EXPLR-III-PMH

EXPLR-III-MBK

Owner’s Manual

Operation & Care

INSTALLER: Leave this manual with party responsible for use and operation. 
OWNER: Retain this manual for future reference. 

Contact your dealer with questions on installation, operation, or service.

 HOT 

SURFACES!

 

Glass and other surfaces are hot  

 

during operation AND cool down. 

Hot glass will cause burns.

• 

Do not touch glass until it is cooled

• 

NEVER allow children to touch glass

• 

Keep children away

• 

CAREFULLY SUPERVISE children in same room as 
fi replace.

• 

Alert children and adults to hazards of high temperatures

• 

High temperatures may ignite clothing or other 
fl ammable materials.

• 

Keep clothing, furniture, draperies and other fl ammable 
materials away.

 WARNING

If the information in these instruc-
tions is not followed exactly, a 
fi re may result causing property 
damage, personal injury, or death.

 

•  Do not store or use gasoline or other fl am-

mable vapors and liquids in the vicinity of 
this or any other appliance.

•  Do not overfi re - If heater or chimney con-

nector glows, you are overfi ring. Overfi ring 
will void your warranty.

•  Comply with all minimum clearances to 

combustibles as specifi ed.  Failure to 
comply may cause house fi re.

WARNING

Fire Risk

For use with solid wood fuel only.
Other fuels may overfi re and generate 
poisonous gases (i.e. carbon monoxide).

WARNING

NOTE

To obtain a French translation of this manual, please contact 
your dealer or visit www.quadrafi re.com

Pour obtenir une traduction française de ce manuel, s’il vous 
plaît contacter votre revendeur ou visitez www.quadrafi re.com

Installation and service of this 
appliance should be performed 
by qualifi ed personnel.  Hearth & 
Home Technologies recommends 
NFI certifi ed professionals, or tech-
nicians supervised by an NFI certi-
fi ed professional.

Содержание EXPLR-III-PBK

Страница 1: ...es and other flammable materials away WARNING If the information in these instruc tions is not followed exactly a fire may result causing property damage personal injury or death Do not store or use g...

Страница 2: ...AS TOUCHER GARDEZ LES ENFANTS ET LES V TEMENTS LOIN DE L ESPACE D SIGN DE L INSTALLATION LE CONTACT PEUT CAUSER DES BR LURES LAPEAU GARDEZ LES MEUBLES ET LES MAT RIAUX COMBUSTIBLES LOIN DE L ESPACE D...

Страница 3: ...TU Efficiency Specifications 7 C Mobile Home Approved USA ONLY 7 D Glass Specifications 7 2 Operating Instructions 8 A Over Firing Your Appliance 8 B Wood Selection Storage 8 C Burning Process 8 D Aut...

Страница 4: ...nstruction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distributor whichever occurs earl...

Страница 5: ...xplorer III Wood Stove WARRANTY CONDITIONS This warranty is void if LIMITATIONS OF LIABILITY 8 K N N OQ R U Z 8 88 U 8 U Q 8 N N Q Z R N U Q 8 R Z N N 88 N U Q 8 N O K WARRANTY EXCLUSIONS N Z N _ q _...

Страница 6: ...D 4 ADD KINDLING LIGHT THE PAPER 5 WARNING Risk of Fire Close and securely latch the door after the fire has started and after refueling to prevent Spillage of smoke flame and carbon monoxide Spillage...

Страница 7: ...approved for mobile home installa tions in the USA when not installed in a sleeping room and when an outside combustion air inlet is provided The structural integrity of the mobile home floor ceil in...

Страница 8: ...ocess C Burning Process In recent years there has been an increasing concern about air quality Much of the blame for poor air quality has been placed on the burning of wood for home heating In order t...

Страница 9: ...learn how to operate your stove with ease E Air Controls 1 Burn Rate Air Control This air supply enters at the upper front of the firebox near the top of the glass door This preheated air supplies th...

Страница 10: ...intain a continuous fire throughout the season F Burn Rates and Operating Efficiency This wood heater has a manufacturer set minimum low burn rate that must not be altered It is against federal reg ul...

Страница 11: ...reaking or damaging the baffle boards DO NOT operate the stove without baffle boards Fire Risk Firebox damage due to improper baffle place ment is not covered by warranty Operate the wood burning appl...

Страница 12: ...hat no smoke column can be seen As you become familiar with your appliance you should periodically check the opacity This will allow you to know how to burn as nearly smoke free as possible goal of 0...

Страница 13: ...of the appliance Avoid installing the appliance near doors walkways or small isolated spaces Recessed lighting should be a sealed can design Attic hatches weather stripped or sealed Attic mounted duct...

Страница 14: ...Wood WEEKLY or After Every 25 Loads of Wood Keep door and glass gasket in good shape to maintain good burn times on a low burn setting To test place a dollar bill between the stove and door and then...

Страница 15: ...creosote or soot has accumulated it should be removed to reduce the risk of a chimney fire B General Maintenance Fire Risk Do not use chimney cleaners or flame colorants in your appliance Will corrod...

Страница 16: ...ill be flowing over the glass and the smokey relatively cool condition of a low fire will cause the glass to become coated Operating the appliance with the Burn Rate Air Control and Start UpAir Contro...

Страница 17: ...t height refer to Chimney Height Section Refer to Negative Pressure section Wood condition is too wet too large Use dry seasoned wood refer to Seasoned Wood Section Bed of coals not established before...

Страница 18: ...retainer alternately a few turns at a time until the glass is secure DO NOT OVERTIGHTEN 9 Replace the door on the appliance Quadra Fire stoves are equipped with ceramic super heat resistant glass whi...

Страница 19: ...disc and spade connectors back inside bracket Reassemble in reverse order E Secondary Tube Baffle Board Removal Be sure to soak with penetrating oil for 15 to 20 minutes before trying to remove the b...

Страница 20: ...20 7060 227D February 25 2016 Explorer III Wood Stove...

Страница 21: ...February 25 2016 7060 227D 21 Explorer III Wood Stove Date of Service Performed By Description of Service A Service Maintenance Log 6 Reference Materials...

Страница 22: ...or SKU Mfg Dates Matte Black EXPLR III MBK 02 15 Porcelain Black EXPLR III PBK 02 15 Porcelain Dark Blue EXPLR III PDB 02 15 Porcelain Frost EXPLR III PFT 02 15 Porcelain Mahogany EXPLR III PMH 02 15...

Страница 23: ...Porcelain Dark Blue 7060 101PDB Porcelain Black 7060 101PBK Porcelain Frost 7060 101PFT 9 Side Left Matte Black 7060 034MBK Porcelain Mahogany 7060 034PMH Porcelain Dark Blue 7060 034PDB Porcelain Bl...

Страница 24: ...141 14 9 Nut 2Wy Side Lock Jam 3 Pkg of 24 226 0100 24 Y 14 10 Key Cam Latch 430 1151 15 Front Matte Black 7060 103MBK Porcelain Mahogany 7060 103PMH Porcelain Dark Blue 7060 103PDB Porcelain Black 70...

Страница 25: ...36 Timer Only Replacement Assembly SRV480 1940 Y 29 Secondary Channels Qty 2 req SRV7060 208 30 Baf e Assembly SRV7060 025 30 1 Baf e Cover Top Includes Insulation Blanket SRV7060 238 30 2 Baf e Blank...

Страница 26: ...Touch Up Matte Black 812 0910 Porcelain Mahogany 855 1450 Porcelain Dark Blue 1 00 0020 Porcelain Black 1 00 0022 Porcelain Frost 1 00 0021 ACCESSORIES Blower Assembly BK ACC Blower Control Box W Swi...

Страница 27: ...February 25 2016 7060 227D 27 Explorer III Wood Stove...

Страница 28: ...eration DO NOT DISCARD Please contact your Quadra Fire dealer with any questions or concerns For the number of your nearest Quadra Fire dealer log onto www quadrafire com CONTACT INFORMATION This prod...