background image

User and installation

manual

Complement to the "Manual of installation, maintenance and assistance"

Technical issue DQ004001

SERIAL INTERFACE RS 232C / RS 422 (OPTIONAL RS 485)

IQ004

This product is an electronic instrument and is thus not to be considered as a machine.

Consequently, it is not subject to the requirements stated in EEC Directive 89/392 (Machines

Directive). It is hereby specified that, if the QEM instrument is used as a component part of

a machine, it must not be switched on if the machine does not comply with the Machines

Directive.

The instrument mark does not absolve the Customer fromthe fulfilment of his or her

legal obligations regarding the finished product.

Summary of Contents for IQ004

Page 1: ... be considered as a machine Consequently it is not subject to the requirements stated in EEC Directive 89 392 Machines Directive It is hereby specified that if the QEM instrument is used as a component part of a machine it must not be switched on if the machine does not comply with the Machines Directive The instrument mark does not absolve the Customer fromthe fulfilment of his or her legal oblig...

Page 2: ...DESCRIPTION Instrument presentation 2 1 Technical electrical and mechanical features 2 2 CHAP 3 OPERATOR MACHINE INTERFACE Inputs and outpts description 3 1 CHAP 4 INSTALLATION Mechanical installation 4 1 Electrical installation 4 2 CHAP 5 ASSISTANCE Instructions on how to fill up the Technical Assistance Fax 5 1 Guarantee 5 2 Ordering code 5 3 ...

Page 3: ...Pag 2 di 15 IQ004 CHAPTER 1 Complementarity References Responsability and validity INTRODUCTION ...

Page 4: ...ase of misunderstandings please contact QEM for any further explanation by sending the Assistance Fax which you find enclosed to the manual 1 2 REFERENCES The documentation concerning the instruments which are designed and sold by QEM has been divided into various sheets in order to allow an effective and quick reading according to the information being seeked Inthismanualallbasicinstructionsforth...

Page 5: ... by QEM Any infraction shall provoke a request of indemnization for damages on behalf of QEM All rights generated by patents or models are reserved QEMreservestherighttopartiallyorintegrallymodifythecharacteristicsoftheinstrumentdescribedandtheenclosed documentation Purpose The purpose of this manual is to indicate the general rules to use the instrument described Indication Write down and careful...

Page 6: ...Pag 5 di 15 IQ004 CHAPTER 2 DESCRIPTION Instrument presentation Technical electrical and mechanical features ...

Page 7: ... receives in RS232C and transmits in RS485 it is necessary to introduce a delay time between one character and the following the delay being function of the transmission speed refer to table Option Speed baud Delay time MD1 4800 250 ms MD2 9600 100 ms MD3 19200 50 ms MD4 38400 30 ms For a correct functionality of the interface the equipments connected to serial port RS485 once received the data mu...

Page 8: ...f all the indications explained in the Manual of installation maintenance and assistance have been respected Ac power supply IQ004 Instrumentpowersupply 24 or 110 or 220 Vac 15 50 60 Hz Absorption in the maximum hardware configuration 3 VA Dc power supply IQ004 versione V Instrumentpowersupply 9 18 Vdc Maxcurrent 150 mA power supply 15 Vdc Serial ports Correspondingtoelectricalstandardsdefinedbyth...

Page 9: ...Pag 8 di 15 IQ004 CHAPTER 3 Inputs and outputs description OPERATOR MACHINE INTERFACE ...

Page 10: ...ative reception RS 422 Connections with DC power supply 1 2 3 4 5 10 6 8 11 7 9 N C Not connected TX Transmission RS 232C RX Reception RS 232C Positive power supply voltage Vdc 9 18 Vdc Negative power supply voltage Vdc 9 18 Vdc GND Ground connection GND Ground RS 232C TX A Transmission RS422 or channel A RS 485 DO RI TX B Negative transmission RS 422 or channel B RS 485 DO RI RX Reception RS 422 ...

Page 11: ...Pag 10 di 15 IQ004 CHAPTER 4 INSTALLATION Mechanical installation Electrical installation ...

Page 12: ...e with the appropriate anti static care Note for DC power supply connections Connect the power supply 0 V to the ground and to the metal mass Cable braiding must be connected to gorund Pleaserefertothe Manualofinstallation maintenance and assistance Do not use the ground connection for current return Instrument s terminals ATTENTION Before make any operation on connectors or instrument turn off th...

Page 13: ...Pag 12 di 15 IQ004 CHAPTER 5 ASSISTANCE InstructionsonhowtofilluptheTechnicalAssistanceFax Guarantee Ordering code ...

Page 14: ...on and here at QEM s we really wish you a good job REMARK If you must send an instrument to be repaired please strictly follow our instructions indicated here below If possible use the original packaging in any case the packaging must protect the instrument against shocks due to transport Insert into the package a detailed description of the malfunction you found and the part of wiring diagram whi...

Page 15: ... 110 Vac 220 220 Vac Interface RS232C RS485 MD1 Transmission speed 4800 baud MD2 Transmission speed 9600 baud MD3 Transmission speed 19200 baud MD4 Transmission speed 38400 baud The empty box indicates an option not required The bos with an abbreviation indicates options that are necessary in the ordering code XX X ...

Page 16: ...Pag 15 di 15 IQ004 REMARKS ...