background image

DIGITAL CLOCK 

Part 41357G & 61357G 

 

 

 

 

TIME SIGNAL 

TIME FORMAT SETTNGS 

INSTALLATION 

 

The 41357G/61357G requires time signal from a Master Clock.  The clock may be connected to any of the following 

Pyramid Time System devices to receive time signal: 

 

9T1W1 

 

TimeTrax Sync 902-928 MHz RF Wireless Shelf Transmitter 

 

S9DSXOLAUB 

TimeTrax Sync 902-928 MHz Secondary Shelf Transmitter 

S9DWXSLAUB 

TimeTrax Sync 902-928 MHz RF Wireless Wall Transmitter 

42337 

 

TimeTrax Sync 902-928 MHz Secondary Wall Transmitter   

 

TTELITEEK   

TimeTrax Elite Biometric Time & Attendance System 

 

TTPROXEK   

Time Trax Elite Proximity Time & Attendance System 

 

7000 

 

7000 Master Clock Controller

1

 

 

 

1

The 7000 Master Clock Controller is able to time correct up to 100 clocks. The  Pyramid Master Clock Controller Booster (#7050) in conjunction with the  Master Clock Controller is able to control up 

to 100 additional clocks.  

 

NOTE: 

The 41357G/61357G may receive its time source from any Master Clock System that supplies BCD, 58

th

 minute (synchronous wired) correction, or 59

th

 minute correction. Pyramid Time 

Systems strongly recommends using the Pyramid 7000 Master Controller, which sends an update correction signal every minute utilizing a BCD correction method.  Most other Master Clock Systems 

which utilize a 58

th

 or 59

th

 minute correction, will update the clock once or twice daily.  Clocks using a 58

th

 or 59

th

 minute correction may be out of synchronization for up to 24 hours verses the 

Pyramid Time System, which may only be out of synchronization for up to one minute following a power interruption. 

 

 

To change time format setting, locate rectangular hole in back of clock that contains 6 pins with a black jumper 

installed. Reposition the jumper according to desired time format settings as shown in Figure 1-3.   

 

 

 

 

 

 

 

 

FIG 1 

FIG 2 

FIG 3 

LOCAL 

12-HR 

Use with Master Clocks 

other than Pyramid or if a 

clock is desired to be a 

different time than 

Pyramid Master 

 

LOCAL 

24-HR 

Use with Master Clocks 

other than Pyramid or if a 

clock is desired to be a 

different time than 

Pyramid Master 

 

PYRAMID 

MASTER CLOCK 

CONTROLLER 

indicates 

jumper 

location 

 

USING PYRAMID TIME SYSTEM DEVICE 

 

Connect Correction/Power Harness to 6 pin Molex on back of  clock.  The clock is powered through 6 pin Molex 

connector. Hardwire black & white wires to 120VAC source, and green wire to ground. 

 

Insert RJ45 BCD signal cable from Pyramid TimeTrax Time & Attendance System, Pyramid 7000 Master Control 

System, or TimeTrax Sync 902-928MHz RF Wireless Transmitter (AUX out from TTSync only) into RJ45 

connector. 

  

Mount clock on wall using mounting holes located on back of clock.  Attach security mounting bracket to single 

or double electrical work box, then attach clock to  bracket using the four hooks.  

 

 

NOTE:  After system is set up and power is applied, the  41357G/61357G clock will take up to 2 minutes to display correct time.  If there 

is not a correction, check that all connections are secure. 

 

 

 

 

 

 

 

 

 

I2048 REV H 

 

 

 

 

4000/4000HD  

Auto Totaling Time Clocks 

 

5000/5000HD 

Auto Totaling Time Clocks 

 

 

Reviews: