background image

RO DRINKING SYSTEM

CT8

USER  MANUAL

Standard 5 Stage Version

Summary of Contents for CT8

Page 1: ...RO DRINKING SYSTEM CT8 USER MANUAL Standard 5 Stage Version ...

Page 2: ......

Page 3: ... QUICK CONNECTORS WORK 5 7 PRODUCT DESCRIPTION 6 8 FLOW CHART 7 9 ACCESSORIES 8 10 FILTER FUNCTION DESCRIPTION RECOMMENDED FILTER REPLACEMENT 9 11 INSTALLATION DIAGRAM 10 12 INSTALLATION 11 13 HOW TO MOUNT THE WATER PURIFIER ON WALL 14 14 FILTER REPLACEMENT for 1st 2nd 3rd and 5th stage 15 15 RO MEMBRANE REPLACEMENT 17 16 TROUBLESHOOTING 19 ...

Page 4: ...ality and other relevant technologies to develop series of versatile and economical RO water purifiers and thus able to provide pure and healthy water You will find Puricom CT8 R3 RO system very easy to maintain with its quick simple sanitary filter replacements The good tasty water flows directly a special is also perfect for beverages such as coffee tea and lemonade Please read this manual caref...

Page 5: ...es of the membrane while the rejected or concentrated is diverted to the drain When the diameter of the pores is less than 0 0001 microns only pure water and a balanced quantity of minerals sodium potassium calcium and magnesium etc can pass through while other substances such as bacteria viruses metals pesticides chemical products etc are eliminated during the process 0 0001μm 5μm 1μm 0 4 1μm 0 0...

Page 6: ...r product performance may be degraded 5 Do not use with hot water Optimal inlet water temperature is 5 45 6 Inlet water pressure is 15 45 PSI 7 Water analysis TDS should not exceed 1000 PPM Hardness should not exceed 250 PPM 8 Ensure the inlet outlet and drain connections are correct and that the drain point is not blocked 9 The filtration system installation shall comply with state and local laws...

Page 7: ...nce of filters is degraded 5 Use with Puricom filter products to maintain expected product lifespan and performance 6 After activated carbon filter replacement a certain amount of carbon fines may be introduced to the water It is food grade activated carbon particles and is harmless to the body 7 Before using the filter for the first time or after replacement of the carbon filter run water for a f...

Page 8: ...pm Temperature 5 45 HOW QUICK CONNECTORS WORK 2 1 Collet Do not remove Insert tubing Push collet in and pull tube out 1 2 safety clip 1 Remove the safety clip from under the collet push in the collet and pull the tube out 2 Ensure the tube is clean and free of burrs Push the tube into the connector until it stops At last pull tube out a little bit and replace the safety clip To disconnect To conne...

Page 9: ...DUCT DESCRIPTION A 1 C B 4 2 3 5 A Lighten Bracket 1 1st Stage Pre filter B Shut off Valve 2 2nd Stage Pre filter C Q PACK Storage Tank 3 3rd Stage Pre filter 4 4th Stage RO Membrane 5 5th Stage Post Filter ...

Page 10: ...7 FLOW CHART OUT IN 1 2 3 TANK Drain Shut off Valve RO Feed Water In To Faucet 5 4 ...

Page 11: ...E Faucet F PVC plug and screws Filters for optional G 1st Stage PP 5μ filter H 2nd Stage Carbon filter I 3rd Stage Carbon CTO PP 1μ filter J 4th Stage RO membrane K 5th Stage Carbon Remineralizing Silver Carbon A B C D E F G H F T 8 2 F T 8 3 I 1 F T 8 3 I 1 F T 8 4 I 1 F T 9 2 K 1 F T 8 6 K 2 F T 8 7 K 3 F T 8 8 J ...

Page 12: ...ties separated by the RO membrane are diverted to the drain 1 3 years FT 86 Post G A C Carbon Drinking water enters this filter after the storage tank and is used as final polishing filter before the faucet It removes objectionable tastes and odors 12 months FT 87 Post Remineralizing Drinking water enters this filter after the storage tank Remineralize drinking water and raises its pH level 12 mon...

Page 13: ...10 INSTALLATION DIAGRAM B D A A D C B B C C Feed Water Drain Pressure Tank Pure Water ...

Page 14: ...veral turns of seal tape on the new feed water connector and install it with the black washer on the existing cold water supply valve 3 Reinstall the existing cold water line on the new feed water connector Wrap several turns of seal tape on the ball valve and install it on the new feed water connector 4 Refer to p 10 Connect the PE tube and complete the feed water assembly ...

Page 15: ...mp evenly on both sides 3 Refer to p 10 Connect the PE tube and complete the drain clamp assembly C Storage Tank Assembly 1 2 1 Connect the PE tube to the quick connector 2 Refer to p 10 Connect the other end of the PE tube to the filter unit s to tank outlet How quick connectors work can refer to p 5 ...

Page 16: ...nto the end of the tube 4 Put the end of the tube into the bottom of the faucet and tighten the nut to complete the faucet assembly Refer to p 10 1 Drill a 12mm hole on the right or left hand side of the sink 2 Install the new faucet in the sink hole and from below the sink assemble the mounting hardware 3 Slide the nut from the bottom of the faucet onto the end of the tube Then place the seal on ...

Page 17: ...C plugs into the wall 3 Use a screwdriver to screw the screws into the PVC plugs The depth of screw protrusion must be uniform 10mm to avoid damage to unit body 4 Aim at the hole of the bracket 5 Hang up the purifier and finish 6 Or it can be placed on the counter leaning against the wall ...

Page 18: ...hten Tighten 1 Turn off feed water at the feed water valve 2 Turn off the storage tank ball valve 3 Turn on the faucet to release pressure from the tubing 4 Follow the arrow direction to unscrew the old filter 5 Replace the filter 6 Follow the arrow direction to screw the new filter ...

Page 19: ...16 7 8 9 7 Turn on feed water at the feed water valve 8 Turn on the storage tank ball valve 9 Allow a tank of water to rinse through the system before use ...

Page 20: ...urn off the storage tank ball valve 3 Turn on the faucet to release pressure from the tubing 4 Pull the disposable RO filter from the bracket 5 Remove the elbow connector out the top and bottom of the RO cartridge 6 Remove the protection caps from the top and bottom of the new RO cartridge ...

Page 21: ... 7 Connect all the fittings 8 Put the RO cartridge into the bracket 9 Turn on feed water at the feed water valve 10 Turn on the storage tank ball valve 11 Allow a tank of water to rinse through the system before use ...

Page 22: ...r to extend the lifespan of the RO membrane No permeate or drain water is produced Shut off valve is worn Replace shut off valve TDS value of permeated water is rising rejection rate is lower than 90 1 The ratio of permeate water to drain water is less than 1 3 1 Flow restrictor is clogged Clean it or replace it 2 RO membrane is worn 2 Replace RO membrane Output of permeate water decreases RO memb...

Page 23: ...20 DEMO ...

Page 24: ...2015 12 D010123001 ...

Reviews: