background image

SuperGenie

Full Manual

Summary of Contents for SuperGenie

Page 1: ...SuperGenie Full Manual ...

Page 2: ...Welcome to Pumpables ...

Page 3: ...p If you suspect a fault or something isn t right email our customer service at hello pumpables co or fill out the claim form at pumpables co warranty We prioritise warranty support and we will get back to you straightaway Facebook chat fb com pumpables Find us on Facebook and send us a message Easiest method for busy mamas Community pumpables co community Get support tips and feed back from other ...

Page 4: ...w here s a list of everything that s included with your pump What s in the box Pump unit Charger 4 international plugs This full manual also tells you all the tips and trick for your Liquid Kit We re always releasing updates Go to pumpables co manuals for the latest version of the manual ...

Page 5: ...off break the seal between the breast and the breast shield with your finger and remove breast shield from your breast Plastic bottles and component parts become brittle when frozen and may break when dropped Take appropriate care in handling bottles and components d d d d d d d d d d d d d d d d d The power adapter is a part of the breast pump Please always check the power adapter before use and i...

Page 6: ... Y C L E V A C U U M Handle Rotate 90 degrees Power Button Long press 2secs On Off Short press Pause Resume Program Button Start customized program Single Double Pumping Cover either air inlet to enable single pumping Vacuum Cycle Button Adjust settings with vacuum and cycle button Mode Button Switch between letdown and expression mode Letdown mode Expression mode Record Ok Button Record pumping s...

Page 7: ...t Careful with your Liquid insert it s fragile The Liquid insert sits insides your shield assembly and fits around your breast During pumping the Liquid insert will draw on your nipple similar to how your baby does This provides a more effective comfortable experience Shield Cover Your shield assembly encases the liquid insert and connects to your bottle Backflow Prevention The shield assembly has a...

Page 8: ...like but it s not necessary Never sterilise or immerse tubing or seal cap You can use any sterilising method that you prefer Here are instructions for sterilising using the boiling method Make sure the pot you choose is large so accessories don t bump into each other Parts can warp if they bump into each other during sterilising 1 Choose a big pot 8 ...

Page 9: ...9 ...

Page 10: ...ime to recharge charging time is 4 hours You can use the pump while charging When assembling the adaptor make sure it clicks into place CLICK Plug into pump Lighting icon will blink during charging L05 01 16 38 CYCLE VACUUM Lighting icon will stop blinking when fully charged L05 01 16 38 CYCLE VACUUM 10 ...

Page 11: ...Getting started Assembling your Liquid Kit 11 ...

Page 12: ... flush with shield Place seal diaphragm on the shield assembly Tip use your finger to ensure the edge is flush This is important so the kit is airtight L 0 3 2 0 3 0 8 0 CY CL E VA CU UM Attach your seal cap then use your tubing to connect your accessory kit to the pump motor Don t forget to cover the unused air port if you re single pumping ...

Page 13: ...ams The SuperGenie pump app can be downloaded through the App Store or Google Play Once you have downloaded the app please follow the instructions to connect your SuperGenie and get set up You ll need to enable location access so that the app can use a lower energy bluetooth setting If you need help just let us know 13 ...

Page 14: ...iring SuperGenie is connected L0000 00 00 CYCLE VACUUM 2 seconds Switch between modes Change between letdown and expression mode by pressing mode button Letdown mode Vacuum strength 1 5 Cycle speed 72 104 Expression mode Vacuum strength 1 16 Cycle speed 40 70 L0000 00 00 CYCLE VACUUM L0000 00 00 CYCLE VACUUM 14 ...

Page 15: ... 01 16 70 CYCLE VACUUM Mode icon blinks when pumping stops Adjust settings Adjust settings with the vacuum and cycle button L05 01 16 104 CYCLE VACUUM CYCLE VACUUM Turn off SuperGenie Press power button for 2 seconds to turn off SuperGenie L0000 00 00 CYCLE VACUUM 2 seconds 15 ...

Page 16: ... 3 Finish recording by pressing record OK button 4 Select the program to save by pressing program button L0320 3080 CYCLE VACUUM 5 Confirm Save by pressing record OK button 6 Saved program displayed on the screen You cannot erase programs To overwrite a program select P1 or P2 again after recording a new program L0000 0000 CYCLE VACUUM 16 ...

Page 17: ...Start your program 1 Press program button 2 Choose program by pressing the program button 3 Select program by pressing record OK button 4 Program starts L0300 0046 CYCLE VACUUM 17 ...

Page 18: ...Every woman is different so trying out the different settings is really worth it but here is a program to get you started 1 Attach the Liquid kit to your breast 2 Turn the pump on 3 Put the pump in letdown mode 4 Increase cycle speed to 104 18 ...

Page 19: ...can control your SuperGenie Gen2 from your phone create programs track milk output change default settings update your pump and more 5 Increase vacuum to level two and adjust to comfort level 6 Once milk flow starts or after two minutes switch to expression mode 7 Set cycle speed to 70 4 Set vacuum level to 6 and adjust to comfort level ...

Page 20: ...r and tear Occasional Pumping i e a few times a week Exclusive Pumping i e 8 times a day 2 3 Months 2 4 Weeks Every Month 3 4 Months Check regularly replace as needed Every 6 months Some parts of your kit need replacing regularly depending on how often you pump This is important Worn out parts are the most common reason for a decrease in output Here s an overview of what to replace when ...

Page 21: ...ise Operating Conditions Storage and Shipping Conditions Electronic Shock Protection 15 330mmHG 40 70 CPM Variable 72 104 CPM Variable 1 12kg 2 64 lbs 2 Years 2 5 Hours 4 Hours 1500 Hours China CE Blue and White Single or Double 196 9mm x 162mm x 71mm 7 75in x 6 38in x 2 8in Rechargable Lithium Ion Cylindrical Battery or AC Adaptor ABS PP and Silicone 100 240V 50 60Hz 15V 1 6A Lithium Ion Cylindri...

Page 22: ...fects should be reported to Pumpables as soon as possible after discovery Pumpables reserves the right to investigate the issue or defect before taking any remedy In the event of defect at Pumpables option Pumpables will replace the product free of charge or arrange repair All efforts will be made to reduce inconvenience to the user Where possible arrangements will be made for the return of faulty...

Page 23: ......

Reviews: