background image

CAL. 5M62

®

KINETIC E. S. U. (Electricity Storage Unit)

Power reserve indicator

Energy depletion forewarning function

Instant-start function

Time and date calendar

Rotating bezel
(only for models with rotating bezel)

Summary of Contents for KINETIC 5M62

Page 1: ...L 5M62 KINETIC E S U Electricity Storage Unit Power reserve indicator Energy depletion forewarning function Instant start function Time and date calendar Rotating bezel only for models with rotating bezel ...

Page 2: ...2 DISPLAY AND CROWN BUTTON CROWN a b c Hour hand BUTTON Second hand Date Minute hand a Normal position c Second click b First click ...

Page 3: ... crown Locking the crown 1 Turn Crown counterclockwise until you no longer feel the threads turning 2 Crown can be pulled out 1 Push Crown back in to normal position 2 Turn Crown clockwise while pressing it lightly until tight Unlocking the crown ...

Page 4: ... HOW TO CHARGE AND START THE WATCH 1 Swing the watch from side to side 2 Charge the KINETIC E S U sufficiently 3 Set the time calendar and put on the watch Swing rhythmically at a rate of twice a second ...

Page 5: ...ngs will reserve up to 1 day of power The second hand will start moving at one second intervals 3 Wear the watch on your wrist It is recommended that the watch be swung further until 2 days of power is reserved As a guideline of recharging an additional 200 to 250 swings about 450 to 500 swings in total will reserve 2 days of power POWER RESERVE NUMBER OF SWINGS 250 450 500 1 day 2 days Max 6 mont...

Page 6: ...ion on see through case back models If your watch has a glass case back do not expose the case back to strong light such as direct sunlight or an incandescent light at close range as this may temporarily increase the power consumption of the watch circuit thus reducing the power reserve in the KINETIC E S U This condition however will be corrected when the case back is turned away from the light W...

Page 7: ...on 5 seconds 10 seconds 20 seconds 30 seconds QUICK MOVEMENT OF SECOND HAND POWER RESERVE Between 1 and 7 days Between 7 days and 1 month The second hand will resume normal movement after the indicated 5 10 20 or 30 seconds have elapsed Approx 1 month Between 4 and 6 months ...

Page 8: ...le the watch is worn on your wrist is stored in the KINETIC E S U It is a power source completely different from conventional batteries for watches and therefore this watch does not require battery replacement The KINETIC E S U is a clean and environmentally friendly power source CAUTION Never install a silver oxide battery for conventional watches in place of the KINETIC E S U The battery may bur...

Page 9: ... time has passed since the watch stopped you can get it started quickly with only a few swings This function is available as long as the watch has been stopped for less than a year When this function is activated the second hand will start moving at two second intervals Swing the watch from side to side to charge the KINETIC E S U by referring to Number of swings and power reserve on page 5 After ...

Page 10: ...nd set the previous day s date 2 Pull out to second click when the second hand is at the 12 o clock position 3 Turn to set the desired date 4 Turn to set the hands to the desired time 5 Push back completely in accordance with a time signal CROWN 3 4 2 Second hand ...

Page 11: ...ow up to 60 minutes of elapsed time 1 Turn the rotating bezel to align its mark with the minute hand 2 Read the number on the rotating bezelthattheminutehandpoints to Start Elapsed time 30 minutes have elapsed For some models the rotating bezel rotates only counter clockwise ...

Page 12: ...not necessary to charge the watch fully as it is charged automatically while it is worn on your wrist While you walk with your watch on your wrist swinging your arm will charge the KINETIC E S U more efficiently than merely swinging the watch by hand Even if the watch is worn on your arm it will not be charged while your arm is not in motion Provided with an instant start function the watch may st...

Page 13: ... is at the 12 o clock position You can immediately press the button again to recheck the power reserve one more time To do so a third time however wait until the second hand resumes normal movement before pressing the button again When the second hand moves at two second intervals the power reserve is very low and the indicator does not function Immediately after the watch is swung to charge the K...

Page 14: ... and then reset the correct time When setting the hour hand check that AM PM is correctly set The watch is so designed that the date changes once in 24 hours Turn the hands past the 12 o clock marker to determine whether the watch is set for the A M or P M period If the date changes the time is set for the A M period If the date does not change the time is set for the P M period When setting the m...

Page 15: ...ton when the watch is wet or in water If used in sea water rinse the watch in fresh water and dry it completely When taking a shower with the water resistant 5 bar watch or taking a bath with the water resistant 10 15 or 20 bar watch be sure to observe the following Do not operate the crown or push the button when the watch is wet with soapy water or shampoo If the watch is left in warm water a sl...

Page 16: ...y from close contact with magnetic objects Do not leave your watch in very low temperatures below 10 C 14 F for a long time since the cold may cause a slight time loss or gain However the above conditions will be corrected when the watch returns to normal temperature Your watch works with stable accuracy within a temperature range of 5 C and 35 C 41 F and 95 F N S To prevent possible rusting of th...

Page 17: ...ay become discolored deteriorated or damaged If your watch has a protective film and or a sticker on the case back be sure to peel them off before using your watch SHOCKS VIBRATION CHEMICALS PERIODIC CHECK PRECAUTION REGARDING CASE BACK PROTECTIVE FILM It is recommended that the watch be checked once every 2 to 3 years Have your watch checked by an AUTHORIZED PULSAR DEALER or SERVICE CENTER to ens...

Reviews: