background image

*359608*

BOOSTER PUMP

 O  W  N  E  R ‘ S    M  A  N  U  A  L

INSTALLATION, OPERATION & PARTS

115/230V/60Hz/1Ph - 79214 1 HP Model

© 2010 Arch Chemicals, Inc.
1200 Lower River Road, Charleston, TN 37310
1-800-310-TECH(8324)

Pulsar® is a registered trademarks of Arch Chemicals Inc. Plasto-Joint Stik® is a registered trademark of La-Co Industries,
Inc. Teflon® is a registered trademark of E.I. Du Pont De Nemours and Company Corporation. Unless noted, names and
brands of others that may be used in this document are not used to indicate an affiliation or endorsement between the
proprietors of these names and brands and Pentair Water Pool and Spa, Inc. Those names and brands may be the
trademarks or registered trademarks of those parties or others.
05-26-10                                                                                                                                               

 359608 (Rev. A)

This manual should be given to the user of this pump.

Summary of Contents for 79214 1 HP

Page 1: ...k of La Co Industries Inc Teflon is a registered trademark of E I Du Pont De Nemours and Company Corporation Unless noted names and brands of others that may be used in this document are not used to indicate an affiliation or endorsement between the proprietors of these names and brands and Pentair Water Pool and Spa Inc Those names and brands may be the trademarks or registered trademarks of thos...

Page 2: ...ssure tests 1 Do not connect system to a high pressure or city water system 2 Use equipment only in a pool or spa installation 3 Trapped air in system can cause explosion BE SURE all air is out of system before operating or testing equipment Before pressure testing be sure to follow the safety checks listed below Check all clamps bolts lids and system accessories before testing Release all air in ...

Page 3: ...pipe threads with one to two layers of Teflon tape Cover entire threaded portion of pipe Do not overtighten or tighten past thread stop in pump port If leaks occur remove pipe clean off old tape rewrap with one to two additional layers of tape and remake the connection NOTICE Support all piping connected with pump Piping Use at least 1 1 2 38mm pipe use 2 51mm pipe if possible Increase size if a l...

Page 4: ... shock turn OFF power to motor before working on electrical connections Ground Fault Circuit Interrupter GFCI tripping indicates an electrical problem If GFCI trips and will not reset have a qualified electrician inspect and repair electrical system Exactly match supply voltage to motor nameplate voltage Incorrect voltage can cause fire or seriously damage motor and voids warranty If in doubt cons...

Page 5: ...tor when not wiring with conduit be sure to seal wire opening on end of motor Use Ground Fault Circuit Interrupter GFCI as master on off switch it will sense a short circuit to ground and disconnect power before it becomes dangerous to pool users Test according to maker s instructions In case of power outage check GFCI for tripping which will prevent normal water circulation Reset if necessary Ris...

Page 6: ...rranty NOTICE Do not use anti freeze solutions except propylene glycol in your pool spa system Propylene glycol is non toxic and will not damage plastic system components other anti freezes are highly toxic and may damage plastic components in the system TABLE I RECOMMENDED FUSING AND WIRING DATA NOTICE 79214 pumps use 60 Cycle current only Serv to Motor Dist in Ft M Motor Branch Fuse Max Load Vol...

Page 7: ... 8 Close all drain valves and replace all drain plugs in piping system 9 Prime pump according to instructions on Page 6 PUMP SERVICE Pump should only be serviced by qualified personnel Be sure to prime pump Pg 6 before starting 1 STOP PUMP before proceeding 2 CLOSE GATE VALVES in suction and discharge pipes 3 RELEASE ALL PRESSURE from pump and piping system To avoid dangerous or fatal electrical s...

Page 8: ...o scratch or mar polished surface or seal will leak 4 Replace slinger on end of motor shaft so that impeller sleeve will push it into position If slinger shows signs of wear or damage replace it 5 Remount seal plate on motor Tighten bolts to 60 80 inch lbs 69 92 kg cm torque 6 Apply a small amount of liquid detergent to inside diameter of rotating half of seal 7 Slide rotating seal member polished...

Page 9: ...der Installing New Seal Page 8 for reassembly 2 Impeller and diffuser may be worn If so order replacement parts from Repair Parts List Page 10 Electrical 1 Pump may be running too slowly check voltage at motor terminals and at meter while pump is running If low see wiring instructions or consult power company Check for loose connections 2 Pump may be too hot A Check line voltage if less than 90 or...

Page 10: ...0 Diffuser 1 C1 270PC 11 Diffuser O Ring 1 U9 374 12 Pump Body Only 1 17303 0001 13 Drain Plug and O Ring 1 U178 920P 14 Hi Lo Screw 5 16 14x5 8 2 U30 919SS 15A Base Corrosion Resistant 1 C4 77P 16A Motor Pad for Corrosion Resistant Base 1 C35 45 17 Screw 8 32x7 8 Rd Hd 7 U30 542SS 18 Lock Washer 8 Ext Tooth 7 U43 21SS 19 Flat Washer 3 8 6 U43 62SS 20 Lock Washer 3 8 6 U43 12SS 21 Nut 3 8 16 Hex 6...

Page 11: ...Blank Page ...

Page 12: ...359608 Rev A 05 26 10 359608 ...

Page 13: ...e enregistrée de La Co Industries Inc Teflon est une marque de commerce enregistrée de E I Du Pont De Nemours et Company Corporation À moins qu il en soit indiqué autrement l utilisation des noms et des marques des produits autres que les siens dans ce document ne présuppose nullement l affiliation entre les propriétaires de ces noms et marques de commerce et Pentair Water Pool and Spa Inc ou leur...

Page 14: ...sur une pression élevée ou sur l eau de la ville 2 N utiliser l équipement qu avec une piscine ou une cuve à remous 3 De l air emprisonné dans le système risque de causer une explosion S ASSURER que tout l air est chassé du système avant de faire fonctionner l équipement ou de le contrôler Avant de procéder à un contrôle de pression procéder aux vérifications de sécurité suivantes Vérifier tous le...

Page 15: ...op serrer ou serrer au delà de la butée filetée de l orifice de la pompe En cas de fuites débrancher le tuyau enlever tout le ruban envelopper les filets d une ou deux couches de nouveau ruban puis rebrancher le tuyau NOTA Toute la tuyauterie branchée sur la pompe doit être supportée Tuyauterie Utiliser des tuyaux en PCV ayant au moins 38 mm 1 1 2 pouce de diamètre dans la mesure du possible utili...

Page 16: ...es voire mortels Ne pas connecter à la terre sur une conduite de gaz Pour éviter tout choc électrique dangereux voir mortel COUPER l arrivée de courant parvenant au moteur avant de travailler sur les connexions électriques Le déclenchement de l interrupteur en cas de fuite à la terre indique un problème électrique Si cet interrupteur se déclenche et qu il ne peut pas être réenclenché demander à un...

Page 17: ...rois intérieures de la piscine de la cuve à remous ou thermale Câblage La pompe doit être branchée en permanence sur son propre circuit électrique voir la Figure 4A et 4B ne pas brancher d autres éclairages électriques ni appareils ménagers sur le même circuit Assortir les calibres des conducteurs avec le Tableau I voir la page 6 AVIS Pour empêcher à la saleté à la pluie aux insectes etc de pénétr...

Page 18: ...sage et préparation pour l hiver NOTA Si la pompe gèle elle sera endommagée et la garantie sera annulée NOTA Ne pas utiliser de solutions antigel à l exception de propylène glycol dans la piscine ou dans la cuve à remous Le propylène glycol est un produit non toxique qui n endommagera pas les éléments en plastique du système Les autres antigels sont extrêmement toxiques et risquent d endommager le...

Page 19: ...es bouchons posés pour l hiver sur les tuyauteries 7 Vidanger les solutions antigel du système 8 Fermer tous les robinets de vidange et reposer tous les bouchons de vidange sur le système à tuyauterie 9 Amorcer la pompe conformément aux instructions figurant à la page 6 ENTRETIEN DE LA POMPE La pompe ne doit être entretenue que par du personnel qualifié Ne pas oublier d amorcer la pompe voir la pa...

Page 20: ...ser avec la pression des doigts voir la Figure 6 2 Si le bague d étanchéité en céramique ne se met pas bien en place le déposer l orienter à l endroit vers le haut sur l établi et renettoyer la cavité Il doit être maintenant possible de remettre le bague d étanchéité en céramique en place 3 Si le bague d étanchéité ne veut toujours pas se mettre en place correctement poser une rondelle en carton s...

Page 21: ... opérations 1 à 7 sous Dépose de l ancienne bague d étanchéité à la page 7 rechercher ce qui pourrait boucher l impulseur suivre les opérations 7 à 11 sous Pose d une bague d étanchéité neuve à la page 8 pour le remontage 2 L impulseur et le diffuseur peuvent être usés Dans ce cas commander des pièces de rechange en se reportant à la liste des pièces de rechange à la page 10 ÉLECTRICITÉ 1 La pompe...

Page 22: ...de vidange 1 U178 920P 14 Vis Hi Lo 5 16 14 x 5 8 de po 2 U30 919SS 15A Socle Résistant à la corrosion 1 C4 77P 16A Tampon de moteur pour socle résistant à la corrosion 1 C35 45 17 Vis à tête ronde n 8 32 x 7 8 de po 7 U30 542SS 18 Rondelle frein n 8 denture ext 7 U43 21SS 19 Rondelle plate 3 8 de po 6 U43 62SS 20 Rondelle frein 3 8 de po 6 U43 12SS 21 Écrou à six pans 3 8 16 6 071403 22 Vis à têt...

Page 23: ...Blank Page ...

Page 24: ...359608 Rev A 05 26 10 359608 ...