background image

On-Wall Equipment GearBox™ 

Model: UNI-GB/UNI-GBB

9533-019-021-00

INSTALLATION INSTRUCTIONS

NORTH AMERICA

3130 East Miraloma Avenue

Anaheim, CA 92806 USA

USA and Canada

Phone: 1-800-368-9700

Fax: 1-800-832-4888

Other Locations

Phone: (001) 714-632-7100

Fax: (001) 714-632-1044

EUROPE

Unit 3, The Moorings Business Park, 

Channel Way, Off Blackhorse Road, Exhall

Coventry, England CV6 6RH

Phone: +44 (0) 2476 614700

Fax: +44 (0) 2476 614710

Summary of Contents for On-Wall Equipment GearBox UNI-GB

Page 1: ...0 East Miraloma Avenue Anaheim CA 92806 USA USA and Canada Phone 1 800 368 9700 Fax 1 800 832 4888 Other Locations Phone 001 714 632 7100 Fax 001 714 632 1044 EUROPE Unit 3 The Moorings Business Park Channel Way Off Blackhorse Road Exhall Coventry England CV6 6RH Phone 44 0 2476 614700 Fax 44 0 2476 614710 ...

Page 2: ...erious injury This product is intended for indoor use only Use of this product outdoors could lead to product failure and personal injury Do not install near sources of high heat Do not install on a structure that is prone to vibration movement or chance of impact Contact Premier Mounts with any questions 800 368 9700 techsupport mounts com PRIOR TO THE INSTALLATION OF THIS PRODUCT THE INSTALLATIO...

Page 3: ...articular installation They are not included Make sure your Premier Mounts product has the following hardware and components before beginning installation If there are parts missing and or damaged stop the installation and call Premier Mounts at 800 368 9700 3 8 Drill Bit M6 Drywall Anchors Qty 4 UNI GB Qty 1 UNI GB Hardware M5 x 8mm Lock It Security Screw Qty 4 M5 Security Allen Wrench Qty 1 5 16...

Page 4: ...Management Plate UNI EMP can also be inserted to compactly organize and secure additional equipment Added Security Security screws lock in the side doors to protect the A V components kept inside Mounting Versatility An array of upper and lower mounting slots makes it easy to attach the UNI GB to wood studs or directly to the dry wall Add Audio Replace the side doors with Premier Mounts 2 way spea...

Page 5: ...approximately be the height of the UNI GB Step 3 Use the level to make sure the UNI GB is level from side to side Place the UNI GB over the first mounting point mark and use a pencil to mark the rest of the mounting points Four 4 mounting points must be used Two 2 upper mounting points and two 2 lower mounting points Mounting Point Mark Are you attaching the UNI GB to wood studs or directly to the...

Page 6: ...ep 1 M6 drywall anchor Dry Wall Installation Front view of UNI GB Insert and lightly hammer in four 4 M6 drywall anchors into the drilled holes see drawing Use a Phillips screwdriver to tighten each drywall anchor until the legs have completely compressed against the back of the wall Do not overtighten the drywall anchor Remove the drywall anchor screws and set them aside Return the UNI GB to its ...

Page 7: ... head screws Tighten using a security wrench Repeat this process for the other side as well The storage feature may be used to store electronic components There is an accessible door on each side of the storageenclosure Itmaybesecurelyheldshutwiththeuseof four 4 M5 x 8mm security head screws It may be easiest to pre wire all cables at this time Utilizing the Storage Feature Electronic Components D...

Page 8: ...ure 1 for reference If you are connecting the sound sources directly to the CPA 50 Power Amp and are using the external volume control follow the suggested Option B wir ing diagram Figure 2 and 10k Pot Volume Dia gram Figure 3 for reference Are you replacing the speaker wires If Yes continue to Step 2 on page 9 If No skip to Step 3 on page 9 PC PROJECTOR VGA Audio Audio Line Input Mic Input Premie...

Page 9: ...ach them to the amp Thread the wires through the inner slots of the speaker housing see drawing Re attach the gaskets and back covers with the back cover screws Do not overtighten the back cover screws w Step 3 Amp Receptacle for the Captive Screw Plug Insert the four wires from the speakers into the blue 4 pin captive screw plug supplied with the power amp Use a 1 Phillips screwdriver to tighten ...

Page 10: ...e marks Proceed to Step 3 on page 11 Step 2 M5 drywall anchor Step 1 Installing the Power Amp Use two 2 4 40 x Phillips flathead screws included with the UNI SPKR to attach the CPA 50 power amplifier to the small amp bracket Figure 1 Place the power amplifier inside the UNI GB Use two 2 M4 x 6mm Lock It security screws included with the UNI SPKR to attach the power amplifier and small amp bracket ...

Page 11: ... sound unclear from the sides of the room If Yes slightly pan the tweeters outward If No continue to step 9 µ µ When you are satisfied with the sound re attach the speaker grills Insert and lightly hammer in two 2 M5 drywall anchors included with the UNI SPKR into the drilled holes see drawing Use a Phillips screwdriver to tighten each drywall anchor until the legs have completely compressed again...

Page 12: ...hnical Specifications 16 00 406 40 18 00 457 20 24 00 609 60 9 60 243 71 10 69 271 53 375 9 53 3 52 89 48 3 53 89 56 26 15 664 21 10 69 271 53 Page 12 Visit the Premier Mounts website at http www mounts com Installation Instructions UNI GB ...

Page 13: ...OT APPLY TO YOU What Customers Must Do for Limited Warranty Service If you discover a problem that you think may be covered by the warranty you MUST REPORT it in writing to the address below within thirty 30 days Proof of purchase an original sales receipt from the original consumer purchaser must accompany all warranty claims Warranty claims must also include a description of the problem the purc...

Reviews: