manualshive.com logo in svg
background image

 

Содержание PRO 3.3 10KVA

Страница 1: ......

Страница 2: ......

Страница 3: ...PRO 3 3 10KVA 20KVA 30KVA 40KVA 60KVA 80KVA PRO 3 3 10KVA 20KVA 30KVA 40KVA 60KVA 80KVA DUAL PF 1 ON LINE Uninterruptible Power Supply USER MANUAL ...

Страница 4: ... responsibility or liability for loss or damages whether direct indirect consequential or incidental which might arise out of the use of such information The use of any such information will be entirely at the user s risk Information in this manual is subject to change without notice We make no commitment to update or keep current the information in this manual If you find information in this manu...

Страница 5: ... the risk of fire connect only to a circuit provided with branch circuit overcurrentprotectioninaccordancewiththeNationalElectricalCode NEC ANSI NFPA 70 Output overcurrent protection and disconnect switch must be provided by others To comply with international standards and wiring regulations the sum of the leakage current of the UPS and the total equipment connected to the output of the UPS must ...

Страница 6: ...s performance deterioration or unanticipated results NOTICE is used to address practices not related to personal injury Calls attention to important information best practices and tips NOTE is used to address information not related to personal injury equipment damage and environment This symbol indicates that you should not discard the UPS or the UPS batteries in the trash This product contains s...

Страница 7: ...ction 4 2 2 Rear panel Wiring Terminal view 5 2 3 Single UPS Installation 9 2 4 UPS Installation for Parallel System 14 2 5 Software Installation 17 3 Operations 18 3 1 Button operation 18 3 2 Screen description 18 3 3 Audible Alarm 44 3 4 Single UPS Operation 44 3 5 Parallel Operation 47 3 6 Fault Code 49 3 7 Warning Code 50 4 Troubleshooting 51 5 Storage and Maintenance 53 5 1 Storage 53 5 2 Mai...

Страница 8: ......

Страница 9: ...y heat source Do not block ventilation holes in the UPS housing 1 3 Installation Do not connect appliances or devices which would overload the UPS e g big motor type equipment to the UPS output terminal Place cables in such a way that no one can step on or trip over them Do not block air vents on the housing of the UPS Ensure proper unit spacing of ventilation UPS came equipped with grounding term...

Страница 10: ... affect its safety or effectiveness is not recommended Do not use this equipment in the presence of a flammable mixture with air oxygen or nitrous oxide Connect grounding terminal of UPS to a grounding electrode conductor In accordance with safety standard EN IEC 62040 1 installation has to be provided with a Backfeed Protection system as for example a contactor which will prevent the appearance o...

Страница 11: ...d by any individuals with no previous experience 1 6 Standards Safety IEC EN 62040 1 EMI Conducted Emission IEC EN 62040 2 Category C3 Radiated Emission IEC EN 62040 2 Category C3 EMS ESD IEC EN 61000 4 2 Level 4 RS IEC EN 61000 4 3 Level 3 EFT IEC EN 61000 4 4 Level 4 SURGE IEC EN 61000 4 5 Level 4 CS IEC EN 61000 4 6 Level 3 Power frequency Magnetic field IEC EN 61000 4 8 Level 4 Low Frequency S...

Страница 12: ...ge and check the package contents The shipping package contains One UPS One user manual One monitoring software CD One RS 232 Cable Option One USB Cable One parallel cable only available for parallel model One share current cable only available for parallel model One external battery cable NOTE Before the installation please inspect the unit Be sure that there is no physical damage to the unit Do ...

Страница 13: ... Panel Wiring Terminal View Diagram 1 PRO 10KVA 20KVA Rear Panel Diagram 2 PRO 10KVA 20KVA DUAL Rear Panel Diagram 3 PRO 10KVA 20KVA Input Output Terminal Diagram 4 PRO 10KVA 20KVA DUAL Input Output Terminal 5 ...

Страница 14: ...Diagram 5 PRO 30KVA 40KVA Rear Panel Diagram 6 PRO 30KVA 40KVA Dual Rear Panel Diagram 7 PRO 30KVA 40KVA Input Output terminal Diagram 8 PRO 30KVA 40KVA Dual Input Output Terminal 6 ...

Страница 15: ...Diagram 9 PRO 60KVA front view with door open Diagram 10 PRO 80KVA front view with door open Diagram 11 PRO 60KVA 80KVA Input Output Terminal 7 ...

Страница 16: ...tion port 2 USB communication port 3 Emergency power off function connector EPO connector 4 Share current port only available for parallel model 5 Parallel port only available for parallel model 6 Intelligent slot 7 External battery connector terminal 8 Line input circuit breaker switch 9 Maintenance bypass switch option 8 ...

Страница 17: ...l receptacle as the input power source for the UPS as its rated current is less than the UPS s maximum input current The receptacle may be damaged and destroyed 2 Switch off the mains switch in the building before installation 3 Turn off all the connected devices before connecting to the UPS 4 Prepare wires based on the following table Model Wiring spec AWG mm Input Ph Output Ph Neutral Battery Gr...

Страница 18: ...able to withstand over 80A current It is recommended to use AWG 6 16mm or thicker wire for Phase and AWG 4 25mm or thicker wire for Neutral for safety and efficiency NOTE 6 The cable for PRO 60KVA and PRO 60KVA DUAL should be able to withstand over 120A current It is recommended to use AWG 4 25mm or thicker wire for Phase and AWG 1 50mm or thicker wire for Neutral for safety and efficiency NOTE 7 ...

Страница 19: ...Terminal block wiring diagram for PRO 10KVA 20KVA Terminal block wiring diagram for PRO 10KVA 20KVA Dual Terminal block wiring diagram for PRO 30KVA 40KVA 11 ...

Страница 20: ...Terminal block wiring diagram for PRO 30KVA 40KVA Dual Terminal block wiring diagram for PRO 60KVA 80KVA 12 ...

Страница 21: ... to the rear panel of the UPS Warning Make sure a DC breaker or other protective device between UPS and the external battery pack is installed for added safety If not please install it carefully Switch off the battery breaker before installation NOTE Set the battery pack breaker in OFF position and then install the battery pack Pay special attention to the rated battery voltage marked on the rear ...

Страница 22: ...ance reliability of the wire should be verified Make sure the L N side is correct not reverse or short circuited 2 4 UPS Installation for Parallel System If the UPS is only available for single operation you may skip this section 1 Install and wired the UPS according to the section 2 3 2 Connect the output wires of each UPS to an output breaker 3 Connect all output breakers to a major breaker This...

Страница 23: ...Wiring diagram of parallel system for PRO 10KVA 20KVA DUAL Wiring diagram of parallel system for PRO 30KVA 40KVA Wiring diagram of parallel system for PRO 30KVA 40KVA DUAL 15 ...

Страница 24: ...Wiring diagram of parallel system for PRO 60KVA 80KVA Wiring diagram of parallel system for PRO 60KVA 80KVA DUAL 16 ...

Страница 25: ... on screen instructions to proceed software installation If there no screen shows 1 minute after inserting the CD please execute setup exe file for initiating software installation 2 If you don t have CD The program can be set up by downloading from www powersolid vn or http www power software download com web site You run the setup exe file after downloading the program 3 Follow the on screen ins...

Страница 26: ... the LCD will display main screen There are five sub menus Control measure setting information and data log Touch any sub menu icon to enter into the sub screen MAIN Initializing CONTROL DATA LOG MEASURE ON OFF UPS BATTERY TEST MUTE ALL MEASURE1 MEASURE2 MEASURE3 GENERAL BASIC1 BASIC2 SETTING INFO ON OFF CHARGER DATALOG PARAMETERS CALIBRATION EEPROM TOUCH SYS PARAMETER PASSWORD INSTALL INFO VOL CA...

Страница 27: ...e five icons to represent five sub menus Control measure setting information data log 3 2 2 Control Screen Touch the icon to enter control sub menu D ATALO G I N FO SETTI N G M EASU R E C O N TR O L H O M E 20KVA Bypass M ode 19 52 36 2018 11 07 O N O FF U PS BATT TEST M U TE ALL O N O FF C H AR G ER Touch icon to return back to main screen no matter it s in any screen of any submenu 19 ...

Страница 28: ...0 D ATALO G I N FO SETTI N G M EASU R E C O N TR O L H O M E 20KVA Bypass M ode 19 52 36 2018 11 07 O N O FF U PS BATT TEST M U TE ALL O N O FF C H AR G ER Tur n O n U PS YES N O D ATALO G I N FO SETTI N G M EASU R E C O N TR O L H O M E 20KVA Bypass M ode 19 52 36 2018 11 07 O N O FF U PS BATT TEST M U TE ALL O N O FF C H AR G ER Tur n O f f U PS YES N O TURN ON UPS TURN OFF UPS Battery Test It w...

Страница 29: ...charger Or touch NO to cancel this operation Then the screen will return to the main screen Touch Back to return to CONTROL screen immediately D ATALO G I N FO SETTI N G M EASU R E C O N TR O L H O M E 20KVA Bypass M ode 19 52 36 2018 11 07 O N O FF U PS BATT TEST M U TE ALL O N O FF C H AR G ER BATT Test YES N O D ATALO G I N FO SETTI N G M EASU R E C O N TR O L H O M E 20KVA Bypass M ode 19 52 3...

Страница 30: ...voltage and frequency BYPASS VOL The real time value of R S and T bypass voltage RS ST TR voltage and frequency OUTPUT VOL The real time value of R S and T output voltage RS ST TR voltage and frequency D ATALO G I N FO SETTI N G M EASU R E C O N TR O L H O M E 20KVA Bypass M ode 19 52 36 2018 11 07 O N O FF U PS BATT TEST M U TE ALL O N O FF C H AR G ER Tur n O n C har ger YES N O D ATALO G I N FO...

Страница 31: ...O N TR O L H O M E 20KVA Bypass M ode 19 52 36 2018 11 07 I N PU T W I N PU T VA I N PU T C U R R I N PU T PF R S T TO TAL W 4W 4W 4W 0 0 0 S 0 3A T 0 3A O U TPU T C U R R R 0 3A 0 08 0 08 0 08 O U TPU T PF 0 08 46VA 46VA 46VA 0 0 0 TO TAL VA I N PU T W I N PU T VA R S T 0 0 R 0 3A S 0 3A T 0 3A 0 08 0 08 Measure screen page 3 INPUT W R S and T input power in watt INPUT VA R S and T input power in...

Страница 32: ...wed instead of changing the parameters Setting screen GENERAL It s to set up basic information of the UPS It s not related to any function parameter ADVANCE It s required to enter password to access to the ADVANCED setting There are two types of authority User and Maintainer General Setting Setting screen page 1 Date Time Set the date and time The format is YYYY MM DD HH MM SS The calendar day wil...

Страница 33: ... characters Service Mail Set the service email accounts up to two and the maximum length is 36 characters General screen page 2 Audio Alarm There are two events available to mute You may choose Enable or Disable alarm when related events occur Enable When selected alarm will be mute when related events occur Disable When selected UPS will alarm when related events occur All Mute When enable is sel...

Страница 34: ...is 0000 If entered password is right the page will jump to setting screen If the password is wrong it will ask to enter again Password error page D ATALO G I N FO SETTI N G M EASU R E C O N TR O L H O M E 20KVA Bypass M ode 19 52 36 2018 11 07 ELEC TR O N I C BATTER Y M I SC ELLAN EO U S Advance Setting Menu Page ELECTRİCAL Electrical Setting Page 1 26 ...

Страница 35: ...tem or within 56 64 Hz for 60Hz system Disable is the default setting Bypass Forbid Enable Bypass forbid is allowed When selected it s not allowed for running in Bypass mode under any situations Disable Bypass forbid is not allowed When selected UPS will run in Bypass mode depending on Bypass at UPS off setting It is the default setting Electrical Setting Page 2 Bypass at UPS off Select the bypass...

Страница 36: ... is from 46Hz to 54Hz when the UPS is 50Hz system and from 56Hz to 64Hz when the UPS is 60Hz system BATTERY D ATALO G I N FO SETTI N G M EASU R E C O N TR O L H O M E 20KVA Bypass M ode 19 52 36 2018 11 07 ELEC TR O N I C BATTER Y M I SC ELLAN EO U S BATT W ar ni ng VO L Shut dow n VO L BATT Age BATT Par am et er s 10 7V 14 4V BATT AH H I G H LO W 24 9 11 5V Battery setting page Battery Warning Vo...

Страница 37: ...de Disable After Disable is set once UPS shutdown occurs and the utility restores the UPS will not automatically turn on Shutdown Delay Min UPS will shut down in setting minutes The countdown will start after confirming the pop up screen Restore Delay Min UPS will automatically restart in setting minutes after the UPS shuts down New Password Set up new password to enter ADVANCE User menu ADVANCE M...

Страница 38: ... UPS damage There are five sub menus under Advance Maintainer setting SYS PARAMETER INSTALL INFO VOL CALI CURR CALI INITIAL ELECTRONIC BATT MISCELLANEOUS and UPS SELFTEST SYS PARAMETER SYS PARAMETER Page 1 Model Name Set the UPS model name Serial Number Set the serial number Manufacturer Set the UPS manufacturer Charger Number The number of charging boards installed in the UPS NOTE It s required t...

Страница 39: ... to restart the UPS after setting DATALOG INFO SETTING MEASURE CONTROL HOME 20KVA StanbyMode 19 52 36 2018 11 07 SYS PARAMETER INSTALL INFO VOL CALI CURR CALI LV INITIAL UPS Type 13 6V Float VOL SYS PARAMETER Page 2 INSTALL INFO DATALOG INFO SETTING MEASURE CONTROL HOME 20KVA StanbyMode 19 52 36 2018 11 07 SYS PARAMETER INSTALL INFO VOL CALI CURR CALI 2018 1 SYS Install Date INITIAL BAT Install Da...

Страница 40: ...ltage calibration Click value columns and it will pop up Then each click is 0 1 no matter it s pressing up or down key Press up key to increase 0 1 and press down key to decrease 0 1 Press OK key to confirm the modification VOL CALI Page 2 Line VOL Line voltage calibration Click value columns and it will pop up Then each click is 0 1 no matter it s pressing up or down key Press up key to increase ...

Страница 41: ...ication Bypass VOL Bypass voltage calibration Click value columns and it will pop up Then each click is 0 1 no matter it s pressing up or down key Press up key to increase 0 1 and press down key to decrease 0 1 Press OK key to confirm the modification CURR CALI DATALOG INFO SETTING MEASURE CONTROL HOME 20KVA StanbyMode 19 52 36 2018 11 07 SYS PARAMETER INSTALL INFO VOL CALI CURR CALI 0 0A 0 0 Outp...

Страница 42: ...ATA LOG After clicking DATA LOG it will pop up a message board as shown in above screen Touch YES to clear the DATALOG page Touch Back or No to cancel this operation and back to INITIAL menu page DATALOG INFO SETTING MEASURE CONTROL HOME 20KVA StanbyMode 19 52 36 2018 11 07 SYS PARAMETER INSTALL INFO VOL CALI CURR CALI DATA LOG INITIAL PARAMETERS EEPROM TOUCH CALI CALI Initial the Parameters YES N...

Страница 43: ... MEASURE CONTROL HOME 20KVA StanbyMode 19 52 36 2018 11 07 SYS PARAMETER INSTALL INFO VOL CALI CURR CALI DATA LOG INITIAL PARAMETERS EEPROM TOUCH CALI CALI Initial the EEPROM YES NO INITIAL EEPROM Page EEPROM After clicking EEMPROM it will pop up a message board as shown in above screen Touch YES to clear all setting value in EEPROM Touch Back or No to cancel this operation and back to INITIAL men...

Страница 44: ...frequency function Enable CVCF function is enabled The output frequency will be fixed at 50Hz or 60Hz according to setting of Output Freq The input frequency could be from 46Hz to 64Hz Disable CVCF function is disabled The output frequency will synchronize with the bypass frequency within 46 54 Hz for 50Hz system or within 56 64 Hz for 60Hz system Disable is the default setting Bypass Forbid Enabl...

Страница 45: ...tem The setting range is 139V 146V when the UPS is LV system Bypass FRE Range Set the bypass frequency range The acceptable bypass frequency range from 46Hz to 54Hz when UPS is 50Hz system and from 56Hz to 64Hz when UPS is 60Hz system ECO mode Enable Disable ECO mode Default setting is Disable ECO Voltage Range Set the ECO voltage range L Low voltage point for ECO mode The setting range is from Ra...

Страница 46: ...ould be higher than Shutdown Voltage setting Shutdown Voltage If battery voltage is lower than this point in battery mode UPS will automatically shut down The setting range is 10 0V 12 0V 10 7V is default setting This setting is only available for long run model Battery Parameter Battery AH setting battery capacity MISCELLANEOUS Miscellaneous setting page Auto Restart Enable After Enable is set on...

Страница 47: ...hen UPS type setting is HV Therefore please disconnect all loads and utility first before executing this function Then please change UPS type to HV For the detailed operation please check System Parameter menu under Advance Maintainer directory After changing UPS type to HV you have to restart the UPS After the UPS is restarted please enter Advance screen and enter Maintainer password It will show...

Страница 48: ...n Page 1 Basic Information MCU Version MCU version DSP Version DSP version Serial NO The serial number of UPS Manufacturer The information about manufacturer Service Contact The contact name is set in Basic Setting Service Phone The listed numbers are set in Basic Setting Service Mail The service email account is set in Basic Setting D ATALO G I N FO SETTI N G M EASU R E C O N TR O L H O M E 20KVA...

Страница 49: ...ute Enable disable mode mute function Rated Information Page Rated Information Output VOL It shows output rated voltage Output FRE It shows output rated frequency CVCF Mode Enable Disable CVCF mode Bypass Forbid Enable disable bypass function Bypass at UPS Off Enable disable auto bypass function when UPS is off Auto Restart Enable disable auto restart function ECO Mode Enable disable ECO function ...

Страница 50: ...ge Range The acceptable input voltage range for ECO mode ECO FRE Range The acceptable input frequency range for ECO mode Parameters Information Page 2 BATT Mode Work Time The maximum discharge time in battery mode BATT Warning VOL HIGH High battery warning voltage LOW Low battery warning voltage Shutdown Voltage If battery voltage is lower this point UPS will automatically shut down Battery Age It...

Страница 51: ... Log Screen Touch the icon to enter date log page Data log is used to record the warning and fault information of the UPS The record contains date time code type and description Touch the icon or to page up or down if there are more than one page in the date log Touch the icon to return to main screen Press the icon to go back to main menu Please refer to Section 3 6 and 3 7 for warning and fault ...

Страница 52: ... on the input breaker In Bypass mode the load is not protected by the UPS To protect your precious devices you should turn on the UPS Refer to next step 2 Touch CONTROL and select UPS on off icon It will show Turn on UPS in screen and select Yes Refer to On Off UPS screen 3 In just a few seconds the UPS will enter into AC mode If the mains is abnormal the UPS will operate in Battery mode without i...

Страница 53: ...is connected to the mains and turned on in AC mode the charger will charge the batteries automatically except in battery mode during battery self test overload or when battery voltage is high 2 It s recommended to charge batteries for at least 10 hours before operation Otherwise the backup time may be shorter than expected 5 Battery mode operation 1 When the UPS is in Battery mode the buzzer will ...

Страница 54: ...n off screen 2 Then UPS will cut off power to output terminals 9 Mute the buzzer 1 Touch SETTING and select BASIC item There are two events available to mute Refer to SETTING screen 2 Some warning alarms can t be muted unless the error is fixed Please refer to section 3 3 for details 10 Operation in warning status 1 When LCD screen shows Fault Mode and the buzzer beeps once every second it indicat...

Страница 55: ...ocedure in section 2 4 3 Remove the cover of parallel share current cable port on the UPS connect each UPS one by one with the parallel cable and share current cable and then replace the cover 4 Turn on the parallel system in AC mode a Turn on the line input breaker of each UPS If using dual input unit please also turn on bypass input breaker After all UPSs enter into bypass mode measure the outpu...

Страница 56: ...ble And then remove the unit from the parallel system Second method 1 If the bypass is abnormal you cannot remove the UPS without interruption You must cut off the load and shut down the system 2 Make sure the bypass setting is enabled in each UPS and then turn off the system All UPSs will transfer to Bypass mode Remove all the maintenance bypass covers and set the maintenance switches from UPS to...

Страница 57: ...veform abnormal in T phase None 19 Inverter C A output line to line short circuited None 66 Inverter current sample abnormal None 1A Inverter A negative power fault None 67 Bypass O P short circuited None 1B Inverter B negative power fault None 68 Bypass O P line to line short circuited None 1C Inverter C negative power fault None 69 Inverter SCR short circuited None 21 Battery SCR short circuited...

Страница 58: ...4 IP phase abnormal 33 Locked in bypass after overload 3 times in 30 minutes 05 Bypass phase abnormal 34 Converter current unbalanced 07 Over charge 3A Cover of maintain switch is open 08 Low battery 3C Utility extremely unbalanced 09 Overload 3D Bypass is unstable 0A Fan failure 3E Battery voltage too high 0B EPO enable 3F Battery voltage unbalanced 0D Over temperature 40 Charger short circuited ...

Страница 59: ...via the Bypass Remove excess loads from UPS output After repetitive overloads the UPS is locked in the Bypass mode Connected devices are fed directly by the mains Remove excess loads from UPS output first Then shut down the UPS and restart it Fault code is shown as 43 UPS is overload too long and becomes fault Then UPS shut down automatically Remove excess loads from UPS output and restart it Faul...

Страница 60: ...tral connection If the connection is ok and the warning is still displaying please refer to the LCD setting section to enter the neutral loss check menu to see if the parameter3 is CHE If it is please press the Enter key firstly to make the CHE flash and press the Enter key secondly to make the UPS clear the alarm If the warning still exists please check input fuses of L2 and L3 The L2 or L3 input...

Страница 61: ...precautionary measures may replace batteries and supervise operations Unauthorized persons must be kept well away from the batteries Verify that no voltage between the battery terminals and the ground is present before maintenance or repair In this product the battery circuit is not isolated from the input voltage Hazardous voltages may occur between the battery terminals and the grounding earthin...

Страница 62: ...hase 3 Phase with Neutral Power Factor 0 99 at 100 Load OUTPUT Phase 3 Phase with Neutral Output voltage 360 380 400 415VAC Ph Ph 208 220 230 240VAC Ph N AC Voltage Regulation 1 Frequency Range Synchronized Range 46Hz 54 Hz 50Hz system 56Hz 64 Hz 60Hz system Frequency Range Batt Mode 50 Hz 0 1 Hz or 60Hz 0 1 Hz Overload AC mode 100 110 60min 110 125 10min 125 150 1min 150 immediately Battery mode ...

Страница 63: ...d non condensing Operation Altitude 1000m Acoustic Noise Level Less than 55dB 1 Meter Less than 58dB 1 Meter Less than 65dB 1 Meter Less than 70dB 1 Meter Less than 70dB 1 Meter Less than 75dB 1 Meter MANAGEMENT Smart RS 232 or USB Supports Windows 2000 2003 XP Vista 2008 7 8 10 Linux Unix and MAC Optional SNMP Power management from SNMP manager and web browser Derate capacity to 90 when the outpu...

Страница 64: ......

Отзывы: