background image

Polaris 9300/9300xi Diagnostic Instructions

H0359300 Rev - 

WARN ING

FOR YOUR SAFETY - 

This product must be serviced by a contractor who is licensed and qualified in pool equipment by the 

jurisdiction in which the product will be installed where such state or local requirements exists.  In the event no such state or local 
requirement exists, the installer or maintainer must be a professional with sufficient experience in pool equipment installation and 
maintenance so that all of the instructions in this manual can be followed exactly. Before installing this product, read and follow 
all warning notices and instructions that accompany this product. Failure to follow warning notices and instructions may result in 
property damage, personal injury, or death. Improper installation and/or operation will void the warranty.

I

mproper installation and/or operation can create unwanted electrical hazard which can cause serious injury, property damage, or 

death. 
Connect unit to receptacle protected by a ground fault circuit interrupter (GFCI). Such a GFCI receptacle should be provided by 
a qualified installer and should be tested on a routine basis. To test the GFCI, push the test button. The GFCI should interrupt 
power. Push the reset button. Power should be restored. If the GFCI fails to operate in this manner, the GFCI is defective. If the 
GFCI interrupts power to the pump without the test button being pushed, a ground current is flowing, indicating the possibility 
of an electric shock. Do not use this product. Disconnect the cleaner and have the problem corrected by a qualified service 
representative before using.

KEEP OUT OF REACH OF CHILDREN

1.  Introduction

 

This document gives diagnostic testing instructions 
for the 9300/9300xi Sport. 

 

The instructions were written with safety as the 
priority and must be followed exactly. Not following 
the written procedure or taking shortcuts may 
increase the risk of personal injury. Read through 
the instructions completely before starting the 
procedure. 

2.   Diagnostic Instructions

 

The customer must provide the following items to 
perform the diagnostic testing:

 • 

Control 

Unit

•  Cleaner Head with Floating Cable

Figure 1.  Polaris Quick Diagnostic Test Box

Press to 

STOP the test

Future 

Use

Press to START

9300 or 9300xi test

Summary of Contents for 9300

Page 1: ... GFCI Such a GFCI receptacle should be provided by a qualified installer and should be tested on a routine basis To test the GFCI push the test button The GFCI should interrupt power Push the reset button Power should be restored If the GFCI fails to operate in this manner the GFCI is defective If the GFCI interrupts power to the pump without the test button being pushed a ground current is flowin...

Page 2: ...ting Cable to Test Box Figure 4 Checking for Air Flow Figure 3 Select the Cleaner Model Figure 5 Testing the Control Unit 4 Determine the corresponding button for the model being diagnosed 9300 or 9300xi Press the button to start the test see Figure 3 2 The drive cycle will turn on and will last for approximately five 5 seconds 3 The cleaner will then drive forward for approximately five 5 seconds...

Page 3: ...ace and remove the propeller guard see Figure 6 Figure 6 Remove the Propeller Guard Figure 8 Remove the Propeller Guard Figure 9 Remove the Floating Cable Figure 7 Remove the Propeller and Flow Director 2 Remove the propeller and the flow director see Figure 7 3 Close the cover and turn the cleaner over so that it s resting on its top 4 Remove the four 4 screws from the bottom of the cleaner Remov...

Page 4: ...lashing red lights on the diagnostic panel then the motor block is defective Replace the motor block and return old motor to Zodiac 6 Using the short test cable connect the motor block to the Polaris Quick Diagnostic Test Box see Figure 10 7 Once secured start the diagnostic test see Figure 11 All trademarks referenced herein are the property of their respective owners ZODIAC is a registered trade...

Reviews: